Comparison of the Prevalence of Asynchronies During Mechanical Ventilation With Manual Versus Automatic Adjustment Ventilator Settings Using the INTELLISYNC+® (HAMILTON) Tool. A Randomized Controlled Study

Hospital San Carlos, Madrid1 site in 1 country30 target enrollmentStarted: February 15, 2024Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Terminated
Enrollment
30
Locations
1
Primary Endpoint
Duration of asyncronies

Study Overview

Brief Summary

Asynchronies between the patient and the artificial ventilator are a frequent problem. They may cause altered sleep, ventilator-induced lung injury, prolong length of ICU stay, cause neuro-psycologic complications and increase mortality. Although reducing their incidence through ventilator setting adjustments is possible, they frequently go undetected and it also requires that attendings remain at the bedside to repeatedly modify ventilator parameters. Ventilator systems may detect and automatically adjust parameters of mechanical ventilation. This would avoid delays in detection and adjustment if the intensivist is not immediately available. The investigators intend to study an automatic detection and adjustment tool which is incorporated in the ventilator software.

Detailed Description

The prevalence and time course of asynchronies will be evaluated in subjects under invasive (n=40) or non-invasive (n=40) mechanical ventilation. Intensivist-optimized ventilator settings will be compared to a software tool (Hamilton ventilators, Intellisync+) in its capacity to control and adjust the triggering and cycling by analysis of the ventilator curves.

The outcome variable is the percentage of the duration of asynchronies during the two 2-hour study periods.

This pilot study has a prospective, randomized cross-over design. The order of the 2 study periods will be randomized to either start with "control" with manual adjustment or "automated adjustment" with Intellisync+.

The total sample size is 80 subjects, 40 receiving invasive mechanical ventilation and 40 on non-invasive mechanical ventilation.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Crossover
Primary Purpose
Treatment
Masking
Single (Outcomes Assessor)

Masking Description

Anonymized evaluation

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •Age >17 years
  • •Partial ventilatory support ("SPONT" mode) connected to Hamilton C1 model, irrespective of chronic restrictive or obstructive lung disease, categorized by RCexp (Expiratory time constant): restrictive (RCExp <0.6); obstructive (RCExp >0.9); normal (RCExp 0.6 - 0.9).
  • •Software version SW3.0.0 or superior and the IntelliSync+ software tool available in invasive and non-invasive ventilation.
  • •Presence of asyncronies in pressure and volume curves tracings of the ventilator.
  • •Signed informed content.

Exclusion Criteria

  • •On extracorporeal respiratory support (ECMO or ECCO2R)

Arms & Interventions

Standard of Care

No Intervention

Optimized ventilator settings to control and reduce the number of asynchronies

Activated automatic detection and adjustment of asynchronies

Active Comparator

Active mode of a mechanical ventilator software automatically detecting and adjusting ventilator parameters to control or reduce the number of events.

Intervention: Intellisync+ (Device)

Outcomes

Primary Outcomes

Duration of asyncronies

Time Frame: two hours per study arm

duration of asyncronies expressed as percentage of time during the respective 2-hour study periods

Secondary Outcomes

No secondary outcomes reported