Vibration Induced Reflex Responses and Estimation of TVR
- Conditions
- MusclePhysiology
- Interventions
- Device: vibrator
- Registration Number
- NCT03424551
- Lead Sponsor
- Istanbul Physical Medicine Rehabilitation Training and Research Hospital
- Brief Summary
The aim of this study is to estimate tonic vibration latency and whole body vibration reflex latency
- Detailed Description
This study was included 17 patients with spastic spinal cord lesions and 23 healthy control.
Soleus T-reflex, soleus H-reflex, soleus tonic vibration reflex (TVR), and reflex muscle response induced by whole body vibration was evaluated this study. To obtain the H-reflex response, the tibial nerve in the popliteal region was stimulated by using a stimulator (FE155 Stimulator HC ADInstrument, Oxford UK) with 1 ms-pulse current. The records was taken with the Ag / AgCl electrodes (Kendall ®Coviden, self-adhesive electrodes) placed on skin according to the SENIAM protocol. To obtain T-reflex response, an electronic reflex hammer (Elcon 100-150 Germany) was used. After H-reflex and T reflex records at rest, to obtain Tonic vibration reflex, local vibration was applied to the Achilles tendon at 50, 85, 140, 185, 235 and 265 Hz. To obtain the reflex response induced by Whole body vibration, vibration was applied at 35, 37, 39, 41, 43 and 45 Hz. Tibial nerve stimulation was performed again to determine Hmax during whole body vibration and local vibration.H-reflex records was taken while the subject is sitting on a chair.
The data was recorded with the PowerLab data acquisition device (ADInstrument Oxford UK). For Whole-body vibration, PowerPlate Pro5 (London UK) was used.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 40
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Vibrator vibrator Local or Whole body vibration was applied at six different frequencies to Healthy control and spastic spinal cord injury. For local vibration, vibration frequencies were 50, 85, 140, 185, 235 and 265 Hz . For whole body vibration, vibration frequencies were 35, 37, 39, 41, 43 and 45 Hz
- Primary Outcome Measures
Name Time Method Presynaptic inhibition level 1 day Change in Hmax amplitude during vibration
- Secondary Outcome Measures
Name Time Method
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.
Trial Locations
- Locations (1)
Istanbul Physical Medicine Rehabilitation Training and Research Hospital
🇹🇷Istanbul, Turkey