Plethysmography Curve Variability Depending on the Breath Cycle
- Conditions
- RespirationApneaCirculatory; Change
- Interventions
- Other: Respiratory rateOther: Tidal volumeOther: Apnea
- Registration Number
- NCT05302219
- Lead Sponsor
- Czech Technical University in Prague
- Brief Summary
The aim of the study is to analyze the variability of plethysmography curve depending on the breath cycle (respiratory rate and tidal volume).
- Detailed Description
The plethysmography curve measured by finger sensors using pulse oximetry shows the changes in blood volume at the measured site. The presence of respiratory information within the pulse oximeter signal is a well-documented phenomenon. However, previous studies have mainly focused on extracting the respiratory rate from the plethysmography curve. The aim of this study is to analyze the variability of plethysmography curve as a function of both respiratory rate and tidal volume. Furthermore, the aim is to analyze the possibilities of apneic pause detection from the plethysmography curve.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 10
- healthy volunteers/students from the Czech Technical University in Prague
- any acute illness
- pregnancy
- severe cardiovascular conditions
- severe asthma or other severe respiratory conditions
- diabetes
- hypotension or hypertension
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Measurement of plethysmography curve Respiratory rate Calm measurement of plethysmography curve using pulse oximetry with simultaneous monitoring of the breath cycle. In this experimental arm, participants will vary their breath cycle (different respiratory rates and different tidal volumes). Measurement of plethysmography curve Tidal volume Calm measurement of plethysmography curve using pulse oximetry with simultaneous monitoring of the breath cycle. In this experimental arm, participants will vary their breath cycle (different respiratory rates and different tidal volumes). Measurement of plethysmography curve Apnea Calm measurement of plethysmography curve using pulse oximetry with simultaneous monitoring of the breath cycle. In this experimental arm, participants will vary their breath cycle (different respiratory rates and different tidal volumes).
- Primary Outcome Measures
Name Time Method Variability of plethysmography curve depending on the respiratory rate 1 hour The effect of different respiratory rates (including apnea-zero respiratory rate) on the shape of the plethysmography curve will be evaluated.
Variability of plethysmography curve depending on the tidal volume 1 hour The effect of different tidal volumes (including apnea-zero tidal volume) on the shape of the plethysmography curve will be evaluated.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Faculty of Biomedical Engineering, Czech Technical University in Prague
🇨🇿Kladno, Czechia