Prospective, Multi-center, Randomized First-in-man Trial Examining the Safety and Efficacy of BuMA Supreme eG (Electro Grafting) Based Biodegradable Polymer Sirolimus-eluting Stent and Resolute Integrity Zotarolimus-eluting Durable Polymer Stent in Patients With de Novo Coronary Artery Stenosis.

Sino Medical Sciences Technology Inc.12 sites in 4 countries168 target enrollmentStarted: April 1, 2015Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Phase 2
Status
Completed
Enrollment
168
Locations
12
Primary Endpoint
Late Lumen Loss

Study Overview

Brief Summary

Prospective, multi-center, randomized 1:1, single blind trial using BuMA Supreme versus Resolute Integrity conducted in approximately 14 interventional cardiology centers in The Netherlands, Belgium, Spain and Portugal.

Clinical follow-up will occur at 1, 9 and 12 months post-stent implantation. All patients will undergo repeat angiography at 9 months follow-up. QCA assessment will be performed at baseline (pre- and post-procedure) and at 9 months follow-up.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Treatment
Masking
Single (Participant)

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • •The subject is at least 18 years of age.
  • •Clinical evidence of ischemic heart disease and/or a positive territorial functional study.
  • •Documented stable angina pectoris (Canadian Cardiovascular Society (CCS) Classification 1, 2, 3 or 4) or unstable angina pectoris with documented ischemia (Braunwald Class IB-C, IIB-C, or IIIB-C), or documented silent ischemia
  • •The patient has a planned intervention of a single de-novo lesion in one or two separate major epicardial territories (LAD, LCX or RCA).
  • •Diameter Stenosis≥50 and<100%.
  • •The visually estimated target lesion must be able to be covered by a single BuMA Supreme stent or a single Resolute Integrity stent (for available sizes refer to tables 1 and 2, page 20 and 21).
  • •The target lesion reference diameter must be visually estimated to be ≥2.5 mm and ≤4.5 mm in diameter.
  • •Written informed consent.
  • •The patient agrees to the follow-up visits including a 9 month angiographic follow-up.
  • •Patient must have completed the follow-up phase of any previous study.

Exclusion Criteria

  • •Female of child bearing potential (age <50 years and last menstruation within the last 12 months). Subjects with age <50 who underwent tubal ligation, ovariectomy or hysterectomy can be included.
  • •Evidence of ongoing acute myocardial infarction (AMI) in ECG and/or elevated cardiac biomarkers (according to local standard hospital practice) have not returned within normal limits at the time of procedure
  • •Patient suffered from stroke/TIA during the last 6 months.
  • •Platelet count <100,000 cells/mm3 or >400,000 cells/mm3, a WBC of <3,000 cells/mm3, or documented or suspected liver disease (including laboratory evidence of hepatitis)
  • •Known renal insufficiency (e.g. serum creatinine >2.5mg/dL, or creatinine clearance ≤30 mL/min), or subject on dialysis, or acute kidney failure (as per physician judgment).
  • •Patient undergoing planned surgery within 6 months with the necessity to stop DAPT.
  • •Patient requiring oral anticoagulation (Coumadin, Novel Oral Anticoagulant (NOAC))
  • •History of bleeding diathesis or coagulopathy
  • •The patient is a recipient of a heart transplant
  • •Known hypersensitivity or contraindication to aspirin, heparin, antiplatelet medication specified for use in the study, sirolimus, zotarolimus, or cobalt-chromium.
  • •Other medical illness (e.g. cancer, stroke with neurological deficiency) or known history of substance abuse (alcohol, cocaine, heroin etc.) as per physician judgment that may cause non-compliance with the protocol or confound the data interpretation or is associated with a limited life expectancy
  • •The patient is simultaneously participating in another investigational device or drug study

Arms & Interventions

BuMA Supreme Biodegradable drug coating coronary stent system

Experimental

Implant BuMA Supreme stent only

Intervention: BuMA Supreme Biodegradable drug coating coronary stent system (Device)

Resolute Integrity durable polymer stent system

Active Comparator

Implant Resolute stent

Intervention: Resolute Integrity durable polymer stent system (Device)

Outcomes

Primary Outcomes

Late Lumen Loss

Time Frame: Up to 9 month

The primary endpoint is in-stent Late Lumen Loss (LLL) at 9 months after stent implantation as assessed by off-line QCA.

Secondary Outcomes

  • Angiographic endpoint(9 and 12 month)
  • Clinical endpoint(9 and 12 month)
  • Cinical endpoint(9 and 12 month)