Effect of Wide Pulse Pressure on the Predictability of Stroke Volume Variation for Fluid Responsiveness in Patients Undergoing Off-pump Coronary Artery Bypass Graft
Not Applicable
Completed
- Conditions
- Stroke Volume Variation
- Interventions
- Other: HES 130/0.4 (VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading
- Registration Number
- NCT01404455
- Lead Sponsor
- Severance Hospital
- Brief Summary
The investigators examined the predictability of stroke volume variation for fluid responsiveness in patients with wide pulse pressure undergoing off-pump coronary artery bypass graft
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 66
Inclusion Criteria
-
- Age ≥ 20
-
- elective off-pump coronary artery bypass graft
Exclusion Criteria
-
- arrhythmia
- 2.EF <40%
- 3.valvular heart dz
- 4.pul HTN
- 5.PAOD
- 6.lung dz
- 7.NYHA IV
- 8.ESRD
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Normal pulse pressure HES 130/0.4 (VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading pulse pressure \<60mmHg Wide pulse pressure HES 130/0.4 (VoluvenⓇ, Fresenius Kabi, Graz, Austria) 500mL loading pulse pressure ≥60mmHg
- Primary Outcome Measures
Name Time Method The predictability of stroke volume variation for fluid responsiveness in patients with wide pulse pressure 30 min
- Secondary Outcome Measures
Name Time Method Cut off value of stroke volume variation for predicting fluid responsiveness in patients with wide pulse pressure 30 min
Trial Locations
- Locations (1)
Department of Anesthesiology and Pain Medicine and Anesthesia and Pain Research Institute, Yonsei University College of Medicine
🇰🇷Seoul, Korea, Republic of