Detecting a Central Volume Deficit in Spontaneous Breathing Healthy Volunteers by Systolic Blood Pressure Variation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 13
- 主要终点
- Systolic pressure variation (SPV)
研究概览
简要总结
13 healthy volunteers (4 females) were tilted 45° head-up while breathing through a facemask fitted with an inspiratory and expiratory resistor. A brachial arterial catheter was used to measure blood pressure and thus systolic pressure variation and pulse contour analysis determined stroke volume and thereby cardiac output in order to detect a central volume deficit.
详细描述
Thirteen healthy volunteers (4 women) at an age of 25 years (range 18-36) were recruited through www.forsøgsperson.dk.
The volunteers were placed on a tilt table and provided with a facemask with an opening of 30-33 mm. A Hook ring was fitted with an inspiratory resistor, an expiratory resistor, a combination of the two resistors, or with no resistance and each resistor provides a 7.5 cmH2O threshold resistance. Each resistor was applied for two minutes with variables obtained in the last minute. The table was then tilted 45° head-up to accumulating blood in the legs and therefore a reduction in the central blood volume. Conversely, 20° head-down tilt was used to expand the central blood volume. For each volunteer measurements with the four respiratory interventions was randomized, whereas the tilt table position was in fixed order: supine, head-up tilt, and head-down tilt.
Three-lead ECG recorded heart rate. A 20 G arterial catheter was placed in the brachial artery of the non-dominant arm and connected to a transducer for reading of blood pressure and stroke volume variation (Vigileo-Flotrac™, version 1.07, Edwards Lifesciences, Nyon, Switzerland). Also SV and CO variation and the arterial pressure curve were recorded for subsequent determination of arterial pressure variations. Additionally, a catheter was placed via a brachial vein to the superior caval vein for recording of central venous pressure and SvO2. While the subjects were breathing spontaneously, the respiratory rate was measured by capnography and peripheral oxygen saturation by fingerprobe.
Variation in the arterial pulse pressure (PPV) was 100 x ((PPmax - PPmin) / ((PPmax + PPmin)/2)), where PPmax and PPmin is the maximal and minimal difference between systolic and diastolic pressure during the respiratory cycle, respectively. By the same formula systolic pressure variation (SPV) was calculated.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •healthy volunteers
排除标准
- •pregnancy
- •lactating
- •any regular or acute use of medicine
结局指标
主要结局
Systolic pressure variation (SPV)
时间窗: Two minutes
Relative difference between systolic blood pressure during inspiration and expiration. Meassured in percent.
次要结局
未报告次要终点