GORE® Septal Occluder Clinical Study: A Study to Evaluate Safety and Efficacy in the Treatment of Transcatheter Closure of Ostium Secundum Atrial Septal Defects (ASDs)

W.L.Gore & Associates2 个研究点 分布在 1 个国家目标入组 400 人开始时间: 2012年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
400
试验地点
2
主要终点
Number of Subjects With 6-Month Composite Clinical Success

研究概览

简要总结

The primary objective of the GORE® Septal Occluder Study is to evaluate the safety and efficacy of the occluder device in the treatment of transcatheter closure of ostium secundum atrial septal defects (ASDs). The data obtained in this study will evaluate this next generation device as compared to outcomes of prior studies conducted with the GORE® HELEX® Septal Occluder.

详细描述

Ostium secundum atrial septal defects present as a persistent communication between the atria and are a common congenital cardiac anomaly accounting for approximately 10% of all congenital heart disease. They are one of the most common congenital heart defects to present in adulthood. Untreated, ASDs produce right heart volume overload and progressive impairment over time, including reduced aerobic capacity, atrial dysrhythmias, congestive heart failure, pulmonary hypertension, and potential paradoxical embolism. In the U.S. alone it is estimated that approximately 10,000 new patients per year can be expected to have an ASD. Successful surgical repair of ASD has been performed for 50 years with continued improvement in technique and outcomes. King and Mills reported the first transcatheter closure of ASD in 1976, but the delivery system was quite large and impractical, especially for younger patients. With time, improvements in design concepts and materials discoveries have led to improved results in transcatheter closure systems. Several devices are now available commercially for transcatheter ASD closure.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

性别
All
接受健康志愿者

入选标准

  • ASD less than or equal to 17 mm.

排除标准

  • Conditions that would confound treatment of ASD or complicate distinguishing onset of adverse events.
  • Unable to accommodate device delivery catheter.

结局指标

主要结局

Number of Subjects With 6-Month Composite Clinical Success

时间窗: 6 months

Among subjects with attempted study device closure, the number of subjects who satisfy all of the following components: 1. Technical Success: Successful deployment and retention at conclusion of index procedure of a GORE® CARDIOFORM Septal Occluder 2. Safety Success: * Freedom from any Serious Adverse Event (SAE) through 30 days post-procedure * Freedom from device events (post-procedure embolization, device removal, or other device reintervention) from completion of the implant procedure through 6 months (195 days) post-procedure 3. Closure Success: A clinical residual defect status of occluded or clinically insignificant as determined by the Echo Core Lab at the 6-month evaluation

次要结局

  • Number of Subjects With Technical Success(During procedure; median duration 68 minutes)
  • Number of Subjects With Procedure Success(During procedure; median duration 68 minutes)
  • Number of Subjects With 30-day SAE(30 days)
  • Number of Subjects With 6-Month Closure Success(6 months)
  • Number of Subjects With 12-Month Closure Success(12 months)
  • Number of Subjects With 36-Month Closure Success(36 months)

研究者

发起方
W.L.Gore & Associates
申办方类型
Industry
责任方
Sponsor