IV Contrast Administration: Effect of Three Side Hole Infusion Catheter on CT Image Quality, Infusion Pressure, and Infusion Rates, Compared to a Standard Infusion Catheter

The University of Texas Health Science Center, Houston2 个研究点 分布在 1 个国家目标入组 61 人开始时间: 2016年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
61
试验地点
2
主要终点
Image Quality as Assessed by Ratio of Tissue Density of Main Portal Vein (MPV) to the Aorta

研究概览

简要总结

The purpose of this research study is to compare two types of catheters used for infusing the contrast dye necessary for viewing internal organs during computed tomography (CT) scanning. The standard catheter, which has one hole from which contrast dye enters veins, will be compared to the Becton Dickinson Nexiva Diffusics System catheter, which has three holes for diffusing dye into veins. The purpose of this study is to determine which catheter type gives the best image.

详细描述

This will be a prospective, randomized, controlled trial. The catheter is already in use at our facilities. After informed consent, patients will be randomly given the standard or new catheter in our practice. Envelopes with the random assignment will be available to the individuals consenting patients. Randomization generally ensures that study groups are similar on average. As age, sex, and weight impact image quality, we will collect data on these factors in case randomization results in an imbalance. This will allow for control of these factors in analysis of the data. Data will be collected from CT abdomen pelvis examinations within a 6 month-1 year period in 2016 - 2017. Our primary outcome is image quality, measured as tissue density and distribution of contrast within the liver, spleen, aorta and IVC. Our secondary outcomes include Peak Contrast Infusion Pressure and Injection Flow Rate. Possible adverse events for use of any type of catheter include contrast infiltration into the subcutaneous tissues which is a minor limited event. All infiltrations will be recorded as part of the permanent medical record, documented in the chart, and the referring physician notified. The patient will be assessed by a physician immediately and referred to the ED if necessary for further evaluation. Current technology utilizes Power injector equipment which alerts the technologist to the pressure being achieved. If the injection pressure exceeds 325 psi the Power injector automatically shuts off.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Triple (Participant, Investigator, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients undergoing contrast enhanced CT abdomen pelvis examinations at Lyndon B. Johnson General Hospital in Texas
  • Patients whose access point is the antecubital fossa
  • Patients receiving 20 or 22 gauge catheters for their CT exam
  • Patients scanned on two 64 slice CT scanners at the same hospital

排除标准

  • patients whose access point is other than antecubital fossa

结局指标

主要结局

Image Quality as Assessed by Ratio of Tissue Density of Main Portal Vein (MPV) to the Aorta

时间窗: at the time of CT scanning

The ratio of tissue density measured in the main portal vein (MPV) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality. Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.

Image Quality as Assessed by Ratio of Tissue Density of Inferior Vena Cava (IVC) to the Aorta

时间窗: at the time of CT scanning

The ratio of tissue density measured in the inferior vena cava (IVC) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality. Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.

Image Quality as Assessed by Ratio of Tissue Density of Spleen to the Aorta

时间窗: at the time of CT scanning

The ratio of tissue density measured in the spleen to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality. Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.

Image Quality as Assessed by Rating Scale

时间窗: at the time of CT scanning

Radiologists blinded to catheter type will review images and rate them on a scale of 1 to 10. 10 indicates a better outcome.

次要结局

  • Peak Contrast Infusion Pressure(at the time of CT scanning)
  • Injection Flow Rate(at the time of CT scanning)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Joseph P Hasapes

Assistant Professor

The University of Texas Health Science Center, Houston