The primary endpoint of this study is the presence of any detected

研究概览

简要总结

Highly communicable and virulent diseases, the ongoing threat of emerging infectious diseases, and the prospect of bio-terrorism have become part of the new reality for health care workers. SARS transmission has occurred despite the use of droplet, contact, and airborne precautions. Potential explanations for some of the episodes of "through-precautions" transmission include the possibility of contamination during removal of protective clothing.

The recommended protective systems (PPS) for aerosol generating procedures set out by the US Center for Disease Control and Prevention (CDC) and the Ontario Ministry of Health and Long Term Care (MOHLTC) differ.

The failure of a PPS may be associated with significant consequences in terms of the morbidity and mortality of front-line health care workers. The purpose of this study is to determine if a difference exists between the rate of self-contamination due to deficiencies in contact precautions for individuals wearing either the CDC or MOHLTC recommended PPS.

Study participants will don one of the two recommended PPS, be "contaminated" with an indicator that becomes visible under ultraviolet light, and then assessed for contamination of clothing layers and skin after removal of the PPS. They will then repeat the procedure using the other PPS.

详细描述

Background: Highly communicable and virulent diseases such as severe acute respiratory syndrome (SARS) and "avian influenza", the ongoing threat of other emerging infectious diseases, and the prospect of bio-terrorism have become part of the new reality for health care workers (1). Recent experience with SARS has demonstrated that front-line health care professionals who perform or assist with aerosol generating procedures are at particularly increased risk of infection.

At present, no data exists addressing the question of self-contamination during the removal of personal protective systems used in a health care setting. The latest suggested donning and removal procedures have not been validated with respect to the issue of selfcontamination due to deficiencies in contact precautions.

The failure of a personal protective system or the donning and removal procedures for a personal protective system may be associated with significant consequences in terms of the morbidity and mortality of front-line health care workers. It is imperative that the rate of self-contamination for these two personal protective systems be assessed.

The purpose of this study is to determine if a difference exists between the rate of self-contamination due to deficiencies in contact precautions for individuals wearing either Personal Protective Equipment (PPE) or the Powered Air Purifying Respirator (PAPR).

This will be a prospective, randomized, controlled, crossover study.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Ect
盲法
Single

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Participants will be recruited from the Department of Anesthesiology attending and resident staff, other physician groups requiring PAPR training, and the Department of Respiratory Therapy.

排除标准

  • Individuals will be excluded if they refuse to provide written consent to participate in the study

结局指标

主要结局

The primary endpoint of this study is the presence of any detected

base clothing layer, skin, or hair contamination.

次要结局

  • The secondary endpoints: 1) contamination episodes of any layer, and 2) protective
  • system donning and removal procedure violations