MedPath

To Evaluate the Effect of Moisturizing Creams on Skin Barrier Function

Not Applicable
Completed
Conditions
Dry Skin
Skin Care
Interventions
Drug: Developmental moisturizing cream 1
Drug: Developmental moisturizing cream 2
Other: Standard cleanser soap
Registration Number
NCT03804710
Lead Sponsor
GlaxoSmithKline
Brief Summary

The aim of this study is to evaluate the impact of twice-daily topical application of two different moisturizing creams on skin barrier function for 4 weeks.

Detailed Description

This study will be a randomized, evaluator-blind, single-center, two-treatment regimen, controlled, parallel-group, with a treatment period of 4 weeks. The study will assess the skin barrier function of the two-treatment regimen in healthy participants with dry, sensitive skin on the face and lower legs. All participants will be centrally randomized to one of the 2 treatment groups using an Interactive Response Technology (IRT).

Recruitment & Eligibility

Status
COMPLETED
Sex
Female
Target Recruitment
158
Inclusion Criteria
  1. Participant provision of a signed and dated informed consent document indicating that the participant has been informed of all pertinent aspects of the study before any assessment is performed.
  2. A participant who is willing and able to comply with scheduled visits, the product application schedule, the Lifestyle Considerations, and other study procedures which includes: a) to remove facial make-up at the screening visit to allow visual assessments; b) using other skin-care products is not permitted including but not limited to: leave-on cosmetics, moisturizers, lotions, creams, sunscreens, soaps, cleansing, exfoliation products, etc. on their face or legs, other than the standard soap and study product(s) provided; c) at all post baseline study visit days, participants must cleanse their face and legs with the standard soap and then apply the test product (s) approximately 10-16 hours before each study appointment (i.e. evening before); d) no use of any product on the face or legs, including the standard soap and test product, within 10 hours of all instrumental measurements on visit days (no showering/bathing permitted with soaps/shampoo within this period) will be permitted.
  3. A participant in good general and mental health with, in the opinion of the investigator or medically qualified designee (if the investigator is not suitably qualified), no clinically significant/relevant abnormalities in medical history or upon dermatologist examination, or condition, that would impact the participant's safety, wellbeing or the outcome of the study, if they were to participate in the study, or affect the individual's ability to understand and follow study procedures and requirements.
  4. A participant who responds "Yes" to the following question: Do you consider yourself to have dry, sensitive skin on your face and very dry skin on your legs?
  5. A participant with an overall dryness assessment total score of ≥3 for each side of the face at screening visit (Visit 1) and baseline visit (Visit 2). With no more than 0.5-unit score difference between each side of the face. Including an examiner score of at ≥ 1 (slight) for the roughness parameter.
  6. A participant with an overall dryness assessment total score of ≥6 for each leg at screening visit (Visit 1) and baseline visit (Visit 2). With no more than 1-unit score difference between each leg.
  7. A participant with a Fitzpatrick skin type I-IV.
Exclusion Criteria
  1. A participant who is an employee of the investigational site, either directly involved in the conduct of the study or a member of their family; or an employee of the investigational site otherwise supervised by the investigator; or, a GSK CH employee directly involved in the conduct of the study or a member of their immediate family.

  2. A participant who has participated in other studies (including non-medicinal studies) involving investigational product(s) within 30 days prior to study entry and/or during study participation.

  3. A participant with, in the opinion of the investigator or medically qualified designee, an acute or chronic medical or psychiatric condition or laboratory abnormality that may increase the risk associated with study participation or investigational product application or may interfere with the interpretation of study results and, in the judgment of the investigator or medically qualified designee, would make the participant inappropriate for entry into this study.

  4. A female participant who is pregnant (self-reported) or intending to become pregnant.

  5. A female participant who is breastfeeding.

  6. A participant with known or suspected intolerance or hypersensitivity to the study materials (or closely related compounds) or any of their stated ingredients.

  7. A participant who, in the opinion of the investigator or medically qualified designee, should not participate in the study.

  8. A participant with current or recent (within 6 months before the start of the study) history of atopic lesions and/or eczema.

  9. A participant with a history of allergic reactions to topical-use products, cosmetics or medications or their ingredients.

  10. A participant with any history of significant diseases or medical conditions known to alter skin or eye appearance or physiologic response (e.g. Type 2 diabetes) which could, in the opinion of the Investigator, preclude topical application of the investigational products and/or interfere with the evaluation of the test site reaction.

  11. A participant presenting open sores, pimples, or cysts at the application site (face or lower legs).

  12. A participant with an active dermatosis (local or disseminated) that might interfere with the results of the study.

  13. A participant currently using any medication which in the opinion of the investigator, may affect the evaluation of the investigational product, or place the participant at undue risk

  14. A participant who has used any of the following topical or systemic medications up to 1 month before the screening visit or intends to use during the study period: immuno-suppressants, antihistamines, non-steroidal anti-inflammatory drugs (NSAIDS), and corticosteroids.

  15. A participant who has used oral or topical treatment with vitamin A acid and/or its derivatives up to 1 month before the screening visit or intends to use during the study period.

  16. A participant who intends to use any topical drug or medication on the proposed application areas. A participant who has been vaccinated up to 1 month before the screening visit or is intending to receive a vaccination during their participation in the study.

  17. A participant currently receiving allergy injections, or received an allergy injection within 7 days prior to Visit 1, or expects to begin injections during study participation 19. A participant with a recent history (within the last 5 years) of alcohol or other substance abuse.

  18. A participant with any skin marks on the face or lower legs that might interfere with the evaluation of possible skin reactions (e.g. pigmentation disorders, vascular malformations, scars, tattoos, excessive hair, numerous freckles). 21. Participants with corneal ulcers, keratoconus, blepharitis, meibomitis, pterygium, chemosis, moderately or severe hyperemia or other active ocular diseases. 22. A participant who has previously been enrolled in this study. 23. A participant who is unwilling to abstain from smoking tobacco or using any other nicotine containing products.

  19. A participant with visible sunburn on any of the test sites. 25. A participant with moles, tattoos, scars, hairs, etc. at the test areas if it is likely that they could affect the assessments. 26. A participant who has used self-tanning products on the test areas (face and arms) within 2 weeks prior to the screening visit. 27. A participant who intends to expose their skin to natural or artificial ultraviolet (UV) light (e.g.

sunbathing or tanning beds). 28. A participant with any participant self-assessed or dermatologist dryness parameter score 4 (very severe) on the test areas of the lower legs or face.

  1. Any participant who, in the judgment of the Investigator, should not participate in the study.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Test Product 1Developmental moisturizing cream 1Participants will apply 2 pumps of the test product (approximately 0.3ml x 2= 0.6ml) to the randomly assigned side of the face, including forehead and chin, and 6 pumps of test product (approximately 0.3 ml x 6 = 1.8 ml) to the randomly assigned lower leg (below the knee; above the ankle) topically twice-daily (in the morning and evening) after cleansing.
Test Product 2Developmental moisturizing cream 2Participants will apply pea-sized amount of the test product (approximately 0.6ml) to the randomly assigned side of the face, including forehead and chin, and walnut-sized amount of the test product (approximately 1.8 ml) to the randomly assigned lower leg (below the knee; above the ankle) twice-daily (in the morning and evening) after cleansing.
Standard soap cleanserStandard cleanser soapParticipants will use wet soap with warm water and form lather. Participants will cleanse their entire face and both lower legs (between the knees and ankles) twice daily (morning and evening).
Primary Outcome Measures
NameTimeMethod
Change From Baseline in Trans-epidermal Water Loss (TEWL) Following Application of Test Regimen on Face (Area 1 Compared to Area 2) at Day 29Baseline and Day 29

TEWL was measured using the Tewameter TM 300. TEWL is a non-invasive method to measure the integrity of stratum corneum barrier function. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. The probe was held in place on the skin for one measurement, for 40 sec, to ensure that a stable value has been established. The values of the last 10 sec are averaged as the actual measurement values. An increase in TEWL values shows damage to the skin barrier function. TEWL was measured at area 1 (right face) and 2 (left face) at baseline visit (Visit 2) prior to any study product application and then measured throughout the study period per the study schedule. Change from baseline was calculated as the value at specified visit (Visit 5/Day 29) minus the baseline value.

Secondary Outcome Measures
NameTimeMethod
Change From Baseline in Corneometer Values Following Application of Test Regimen on Legs (Area 5 Compared to Area 6) at Two Different Time-points (30 Mins and 6 Hrs After First Application) at Day 1 and One Time-point at Day 2Baseline, Day 1 and Day 2

SC moisturization measured using the Corneometer CM 825. The measuring principle is based on changes in the capacitance of the measuring head, functioning as condensator. The electric field was created between gold conductors to enable the dielectricity of the SC to be measured. Because the dielectricity varies as a function of the skin's water content, the SC moisturization was measured. Corneometer probe was placed in contact with the skin of the participants test site for 1 to 2 sec per measurement. The measurement will be taken 5 times in total and then an average reading will be calculated for each site and time point. The Corneometer values lower than 30 i.u represent very dry skin and values between 30 to 50 i.u represent dry skin on the forearm. Higher value of Corneometer indicates high moisture content. The area 5 (right leg) and area 6 (left leg) were considered.

Change From Baseline in TEWL Following Application of Test Regimen on Legs (Area 5 Compared to Area 6) at Day 29Baseline and Day 29

TEWL was measured using the Tewameter TM 300. TEWL is a non-invasive method to measure the integrity of stratum corneum barrier function. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. The probe was held in place on the skin for one measurement, for 40 sec, to ensure that a stable value has been established. The values of the last 10 sec are averaged as the actual measurement values. An increase in TEWL values shows damage to the skin barrier function. TEWL was measured at area 5 (right leg) and 6 (left leg) at baseline visit (Visit 2) prior to any study product application and then measured throughout the study period per the study schedule. Change from baseline was calculated as the value at specified visit (Visit 5/Day 29) minus the baseline value (Visit 2).

Change From Baseline in TEWL Following Application of Test Regimen on Face (Area 1 Compared to Area 2) at Day 15Baseline and Day 15

TEWL was measured using the Tewameter TM 300. TEWL is a non-invasive method to measure the integrity of stratum corneum barrier function. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. The probe was held in place on the skin for one measurement, for 40 sec, to ensure that a stable value has been established. The values of the last 10 sec are averaged as the actual measurement values. An increase in TEWL values shows damage to the skin barrier function. TEWL was measured at area 1 (right face) and 2 (left face) at baseline visit (Visit 2) prior to any study product application and then measured throughout the study period per the study schedule. Change from baseline was calculated as the value at specified visit (Visit 5/Day 29) minus the baseline value (Visit 2).

Change From Baseline in TEWL Following Application of Test Regimen on Legs (Area 5 Compared to Area 6) at Day 15Baseline and Day 15

TEWL was measured using the Tewameter TM 300. TEWL is a non-invasive method to measure the integrity of stratum corneum barrier function. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. The probe was held in place on the skin for one measurement, for 40 sec, to ensure that a stable value has been established. The values of the last 10 sec are averaged as the actual measurement values. An increase in TEWL values shows damage to the skin barrier function. TEWL was measured at area 5 (right leg) and 6 (left leg) at baseline visit (Visit 2) prior to any study product application and then measured throughout the study period per the study schedule. Change from baseline was calculated as the value at specified visit (Visit 5/Day 29) minus the baseline value (Visit 2).

Change From Baseline in Corneometer Values Following Application of Test Regimen on Face (Area 1 Compared to Area 2) at Two Different Time-points [30 Minutes (Mins) and 6 Hrs After First Application] at Day 1 and One Time-point at Day 2Baseline, 30 mins and 6 hrs after first treatment application on Day 1 and 24 hrs after treatment application on Day 2

Stratum corneum (SC) moisturization measured using the Corneometer CM 825. The measuring principle is based on changes in the capacitance of the measuring head, functioning as condensator. The electric field was created between gold conductors to enable the dielectricity of the SC to be measured. Because the dielectricity varies as a function of the skin's water content, the SC moisturization was measured. Corneometer probe was placed in contact with the skin of the participants test site for 1 to 2 sec per measurement. The measurement will be taken 5 times in total and then an average reading will be calculated for each site and time point. The Corneometer values lower than 30 international units (i.u) represent very dry skin and values between 30 to 50 i.u represent dry skin on the forearm. Higher value of Corneometer indicates high moisture content. The area 1 (right face) and area 2 (left face) were considered.

Change From Baseline in Corneometer Values Following Application of Test Regimen on Face (Area 1 Compared to Area 2) at Day 15 and 29Baseline, Day 15 and 29

SC moisturization measured using the Corneometer CM 825. The measuring principle is based on changes in the capacitance of the measuring head, functioning as condensator. The electric field was created between gold conductors to enable the dielectricity of the SC to be measured. Because the dielectricity varies as a function of the skin's water content, the SC moisturization was measured. Corneometer probe was placed in contact with the skin of the participants test site for 1 to 2 sec per measurement. The measurement will be taken 5 times in total and then an average reading will be calculated for each site and time point. The Corneometer values lower than 30 i.u represent very dry skin and values between 30 to 50 i.u represent dry skin on the forearm. Higher value of Corneometer indicates high moisture content. The area 1 (right face) and area 2 (left face) were considered.

Change From Baseline in Corneometer Values Following Application of Test Regimen on Legs (Area 5 Compared to Area 6) at Day 15 and 29Baseline, Day 15 and Day 29

SC moisturization measured using the Corneometer CM 825. The measuring principle is based on changes in the capacitance of the measuring head, functioning as condensator. The electric field was created between gold conductors to enable the dielectricity of the SC to be measured. Because the dielectricity varies as a function of the skin's water content, the SC moisturization was measured. Corneometer probe was placed in contact with the skin of the participants test site for 1 to 2 sec per measurement. The measurement will be taken 5 times in total and then an average reading will be calculated for each site and time point. The Corneometer values lower than 30 i.u represent very dry skin and values between 30 to 50 i.u represent dry skin on the forearm. Higher value of Corneometer indicates high moisture content. The area 5 (right leg) and area 6 (left leg) were considered.

Change From Baseline in TEWL Following Application of Test Regimen on Face (Area 1 Compared to Area 2) at Day 30, 31, 32, 33 and 34Baseline, Day 30, 31, 32, 33 and 34

TEWL was measured using the Tewameter TM 300. TEWL is a non-invasive method to measure the integrity of stratum corneum barrier function. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. The probe was held in place on the skin for one measurement, for 40 sec, to ensure that a stable value has been established. The values of the last 10 sec are averaged as the actual measurement values. An increase in TEWL values shows damage to the skin barrier function. TEWL was measured at area 1 (right face) and 2 (left face) at baseline visit (Visit 2) prior to any study product application and then measured throughout the study period per the study schedule. Change from baseline was calculated as the value at specified visit (Visit 5/Day 29) minus the baseline value.

Change From Baseline in TEWL Following Application of Test Regimen on Legs (Area 5 Compared to Area 6) at Day 30, 31, 32, 33 and 34Baseline, Day 30, 31, 32, 33 and 34

TEWL was measured using the Tewameter TM 300. TEWL is a non-invasive method to measure the integrity of stratum corneum barrier function. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. The probe was held in place on the skin for one measurement, for 40 sec, to ensure that a stable value has been established. The values of the last 10 sec are averaged as the actual measurement values. An increase in TEWL values shows damage to the skin barrier function. TEWL was measured at area 5 (right leg) and 6 (left leg) at baseline visit (Visit 2) prior to any study product application and then measured throughout the study period per the study schedule. Change from baseline was calculated as the value at specified visit (Visit 5/Day 29) minus the baseline value.

Change From Baseline in Corneometer Values Following Application of Test Regimen on Face (Area 1 Compared to Area 2) at Day 30, 31, 32, 33 and 34Baseline, Day 30, 31, 32, 33 and 34

SC moisturization measured using the Corneometer CM 825. The measuring principle is based on changes in the capacitance of the measuring head, functioning as condensator. The electric field was created between gold conductors to enable the dielectricity of the SC to be measured. Because the dielectricity varies as a function of the skin's water content, the SC moisturization was measured. Corneometer probe was placed in contact with the skin of the participants test site for 1 to 2 sec per measurement. The measurement will be taken 5 times in total and then an average reading will be calculated for each site and time point. The Corneometer values lower than 30 i.u represent very dry skin and values between 30 to 50 i.u represent dry skin on the forearm. Higher value of Corneometer indicates high moisture content. The area 1 (right face) and area 2 (left face) were considered.

Change From Baseline in Corneometer Values Following Application of Test Regimen on Legs (Area 5 Compared to Area 6) at Day 30, 31, 32, 33 and 34Baseline, Day 30, 31, 32, 33 and 34

SC moisturization measured using the Corneometer CM 825. The measuring principle is based on changes in the capacitance of the measuring head, functioning as condensator. The electric field was created between gold conductors to enable the dielectricity of the SC to be measured. Because the dielectricity varies as a function of the skin's water content, the SC moisturization was measured. Corneometer probe was placed in contact with the skin of the participants test site for 1 to 2 sec per measurement. The measurement will be taken 5 times in total and then an average reading will be calculated for each site and time point. The Corneometer values lower than 30 i.u represent very dry skin and values between 30 to 50 i.u represent dry skin on the forearm. Higher value of Corneometer indicates high moisture content. The area 5 (right leg) and area 6 (left leg) were considered.

Change From Pre-challenge in TEWL Following Application of Test Regimen on Face (Area 3 Compared to Area 4) at 3 Different Time Points of Strips Removal (3,6 and 9) at Day 29Day 31

Tape-stripping method was used to evaluate the impact of physical challenge to the skin barrier after product use. Stripping challenge was performed on D-Squame sites on area 3 (right face) and area 4 (left face) at Day 29 by sequential application and removal of D-Squame adhesive 3, 6, and 9 discs. A Series of D-Squame discs were applied over the areas with uniform pressure for 5 sec with a stamp to ensure consistent adhesion to the skin. The disc was pulled off the skin with one fluent and decisive movement. TEWL was measured pre-challenge and after 3, 6, and 9 discs had been removed. TEWL was measured using the Tewameter TM 300. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. TEWL measurement was taken in triplicate. The average reading was considered for each area and time point. An increase in TEWL values shows damage to the skin barrier function.

Change From Pre-challenge in TEWL Following Application of Test Regimen on Legs (Area 7 Compared to Area 8) at 3 Different Time Points of Strips Removal (4, 8 and 12) at Day 29Pre-challenge and Day 29

Tape-stripping method was used to evaluate the impact of a physical challenge to the skin barrier after product use. Stripping challenge was performed on D-Squame sites on area 3 (right face) and area 4 (left face) at Day 29 by sequential application and removal of D-Squame adhesive 3, 6, and 9 discs. A Series of D-Squame discs were applied over the areas with uniform pressure for 5 sec with a stamp to ensure consistent adhesion to the skin. The disc was pulled off the skin with one fluent and decisive movement. TEWL was measured pre-challenge after 3, 6, and 9 discs have been removed. TEWL was measured using the Tewameter TM 300. Tewameter probe measures the density gradient of the water evaporation from the skin indirectly by two pairs of sensors (temperature and relative humidity) inside a hollow cylinder. TEWL measurement was taken in triplicate. The average reading was considered for each area and time point. An increase in TEWL values shows damage to the skin barrier function.

Total Protein Content Extracted From D-Squame Discs From a Total of 9 Adhesive Discs on Face (Area 3 Compared to Area 4) at Day 29Day 29

Total protein content was measured using the SquameScan 850. SquameScan 850 is an instrument used to measure the protein content extracted from the skin by D-Squame tape strips. The determination is carried out by measuring the optical absorption of the strip at 850 nanometers (nm). Value displayed in percentage (%) was proportionally related to protein content. An 18 D-Squame discs were taken from participant (two sets of 9 discs from each side of the face). The protein content was analyzed for each of the discs obtained from the D-Squame stripping on area 3 (right face) and area 4 (left face) on Day 29.

Total Protein Content Extracted From D-Squame Discs From a Total of 12 Adhesive Discs on Leg (Area 7 Compared to Area 8) at Day 29Day 29

Total protein content was measured using the SquameScan 850. SquameScan 850 is an instrument used to measure the protein content extracted from the skin by D-Squame tape strips. The determination is carried out by measuring the optical absorption of the strip at 850 nm. Value displayed in percentage (%) was proportionally related to protein content. An 24 D-Squame discs were taken from participant (two sets of 12 discs from the two separate sites of each lower leg). The protein content was analyzed for each of the discs obtained from the D-Squame stripping on area 7 (right leg) and area 8 (left leg) on Day 29.

Trial Locations

Locations (1)

GSK Investigational Site

🇩🇪

Schenefeld, Schleswig-Holstein, Germany

© Copyright 2025. All Rights Reserved by MedPath