Skip to main content
Clinical Trials/NL-OMON47584
NL-OMON47584CompletedNot Applicable

Heart failure with preserved ejection fraction (HFpEF), perfusion and metabolism - Heart failure with preserved ejection fraction, early diagnosis

Academisch Medisch Centrum0 sites48 target enrollmentStarted: TBDLast updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
48

Study Overview

Brief Summary

Trial is onging in other countries

Study Design

Study Type
Observational

Eligibility Criteria

Ages
18 to 99 (—)

Inclusion Criteria

  • 1. All patients
  • * Age > 50
  • * Estimated glomerular filtration reserve (eGFR) >30 ml/min
  • * Body weight<130kg ;1.1. HFpEF group
  • *Diagnosis of HFpEF, requires three conditions to be satisfied, as stated in the ESC guidelines:
  • (1) symptoms or signs of heart failure
  • (2) normal or only mildly reduced LV ejection fraction in a non-dilated LV (LVEF><= 50%)
  • (3) relevant structural heart disease (LV hypertrophy/LA enlargement) and/or diastolic dysfunction.
  • *Current BP < 160/90
  • *Estimated glomerular filtration reserve (eGFR) >30 ml/min
  • 1.2 Hypertensive control patients;*No coronary artery disease (CAD; coronary stenosis>70% or history of CABG)
  • *No heart failure
  • *Estimated glomerular filtration rate (eGFR) > 30 ml/min
  • *Preserved left ventricular ejection fraction (LVEF) (><= 50%) on echocardiography
  • *No left ventricular hypertrophy (lateral and septal left ventricular wall <=<10mm)
  • *No left atrium enlargement
  • *No diastolic dysfunction type 2 or 3
  • *Blood pressure >140/90 mmHg or use of anti-hypertensive therapy
  • *Normal cardiac structure and function on echocardiography

Exclusion Criteria

  • A potential subject who meets any of the following criteria will be excluded from participation in this study:;- Age < 50 years
  • - Life expectancy of <1 year (malignancy etc.)
  • - Contraindication for CMR
  • * ODIN protocol:
  • * *Uitvoering van MRI onderzoek bij patiënten met een cardiaal implanteerbaar elektronisch device (CIED), waaronder een pacemaker en ICD*
  • * ODIN protocol:
  • * *Voorbereiding klinische patiënten voor MRI onderzoek*
  • * Metallic implant (vascularclip, neuro-stimulator, cochlearimplant)
  • * Pacemaker or implantable cardiac defibrillator(ICD)
  • * Claustrophobia
  • * Persistent or chronic atrial fibrillation
  • - Contraindication to adenosine:
  • * High degree atrio-ventricular block (2nd or 3rd degree)
  • * Severe asthma bronchial
  • * Chronic obstructive pulmonary disease Gold * III
  • * Concomitant use of dipyridamole (Persantin)
  • * Long QT syndrome (congenital)
  • - Contraindication to gadolinium (Dihydroxy- hydroxymethylpropyl- tetraazacyclododecane-triacetic acid (butrol) - Gadovist ® )
  • * Severe renal impairment (Glomerular filtration rate (GFR) < 30 ml/min/1.73m2

Investigators