NCT06067334已完成不适用
Complete Digital Workflow for Construction of Full Arch Implant Supported Screw Retained Restoration: Accuracy of Different Impressions Techniques on Implant and Abutment Levels (Cross-over Study)
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 10
- 试验地点
- 2
- 主要终点
- Best fit alignment to calculate 3D deviation of each impression
研究概览
简要总结
aim: to compare the accuracy of the conventional and digital impression when will be performed on implant level or abutment level in Complete digital workflow for construction of full arch implant supported screw-retained restoration.
详细描述
The patient will be selected according to the following criteria:
- Free from any systemic disease that may interfere with proper Osseointegration of implants, which will be assessed by thorough medical investigations.
- Patients having completely edentulous maxilla and mandible for at least 6 months after the last extraction.
- Normal maxilla mandibular relationship with adequate inter-arch space, measured by tentative jaw relation.
- Sufficient residual alveolar ridge.
Exclusion criteria include:
- Local or general contraindications for surgical procedures.
- Patients with TMJ disorders or poor neuromuscular coordination or parafunctional habits.
- Severe inter-maxillary skeletal discrepancy or limited inter-arch space.
- Heavy smokers.
- For all patients, conventional complete dentures are constructed.
- Implants installed in the edentulous maxilla and mandible in each target position guided by stereolithographic stent. A delayed loading protocol is followed in this study.
- After osseointegration, a conventional open tray splinted impression technique will be made for each patient on the implant/abutment level.
- Scan bodies' implant level/abutment level will be tightened for each patient, and a digital intraoral scanner will be used to scan the scan bodies for making implant level/abutment level digital impressions.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Crossover
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 50 Years 至 60 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Free from any systemic disease that may interfere with proper Osseointegration of implants, which will be assessed by thorough medical investigations.
- •Patients having completely edentulous maxilla and mandible for at least 6 months after the last extraction.
- •Normal maxilla mandibular relationship with adequate inter-arch space as verified by tentative jaw relation.
- •Sufficient residual alveolar ridge.
排除标准
- •Local or general contraindications for surgical procedures.
- •Patients with TMJ disorders or poor neuromuscular coordination or parafunctional habits.
- •Severe inter-maxillary skeletal discrepancy or limited inter-arch space.
- •Heavy smokers.
结局指标
主要结局
Best fit alignment to calculate 3D deviation of each impression
时间窗: 3 months
3D inspection software (Geomagic Control X) using the best-fit alignment algorithm will be utilized to calculate the 3D deviation of each impression using the root mean square (RMS) error.
次要结局
- Passive fit(3 months)
研究者
Fatma mahanna
lecturer of prosthodontics
Mansoura University
研究点 (2)
Loading locations...
相似试验
已完成
不适用
Evaluation of the Accuracy of Full Digital Workflow for Guided Implant Surgery Using the R2 Gate SoftwarePartially Edentulous MaxillaPartially Edentulous MandibleNCT03814655Concordia Dent Srl54
已完成
不适用
Accuracy of Conventional and Digital Impression Techniques Used for Maxillary Hybrid ProsthesisProsthesis DurabilityNCT05321589Mansoura University12
招募中
不适用
Digital vs Conventional Impression in Capturing the Emergence Profile Around Maxillary Anterior Implant-supported CrownsDental Implants, Single-ToothDental Impression TechniqueNCT06425770Semmelweis University15
尚未招募
4 期
Comparison of dental impression techniques in childreCTRI/2024/05/066991DrD YPatil school of dentistry Navi mumbai
已完成
不适用
Accuracy of full arch digital impressions: an in-vitro and in-vivo comparisohealthy subjectDRKS00015459Align Technology1
