A Randomized Control Trial to Assess the Effectiveness of Apneic Oxygenation in Adults Using Low Flow or High Flow Nasal Cannula With Head Side Elevation Compared With Usual Care to Prevent Desaturation During Endotracheal Intubation
Trial Snapshot
- Phase
- Not Applicable
- Sponsor
- Enrollment
- 30
- Primary Endpoint
- Lowest noninvasive oxygenation value
Study Overview
Brief Summary
Apneic oxygenation is a process of delivering continuous oxygen during direct laryngoscopy. Nasal cannulas are used for the purpose of oxygenation; for delivering either low flow or high flow oxygen but haven't been tested in terms of a superior study design on improving patient outcomes. In this study the investigators propose to assess the effect of giving low flow oxygen with head side elevation versus high flow oxygen with head side elevation against the usual practice of care in which no oxygen is provided during direct laryngoscopy on participant's oxygenation level. This will be a three arm study instituting block randomization technique. There will be no blinding due to the nature of intervention. The primary outcomes are lowest non-invasive oxygen saturation measurement during direct laryngoscopy and two minutes after the placement of the tube and first pass success rate. The intervention is unique as the investigators have introduced head side elevation up to 30 degrees for improving glottis visualization and low or high flow oxygen delivery on grounds to improve oxygenation for patient safety undergoing endotracheal intubation. The technique if proved successful can be employed as a method of airway management in the emergency room. The results of the study will open new horizons for the development of guidelines to utilize it as a routine measure, during airway management in the emergency room.
Detailed Description
Intervention (High Flow and Low Flow):
The participants after fulfilling the eligibility criteria will be randomly assigned to the respective arm (High Flow, Low Flow or Standard). For procedure, depending upon the arm, the head side of the patient bed will be elevated up to 30 degrees in order to better visualize the glottis. The participants in the high flow oxygen delivery through nasal cannula preoxygenation will be set for 4 min at 6 L/min through humidified and heated pure oxygen (fraction of inspired oxygen 100%, 37C). Similarly, participant in the low flow oxygen delivery through nasal cannula preoxygenation will be set for 4 min at 3 L/min through humidified and heated pure oxygen (faction of inspired oxygen 100%, 37C). Throughout the procedure the high flow nasal cannula or low flow nasal cannula will be maintained trying to achieve a continuous oxygen during direct laryngoscopy for RSI.
Standard Arm:
In the standard arm the head end of the bed will not be raised to 30 degrees instead the whole bed is raised up to the operator belly button in order to ease glottis visualization. In the standard group the preoxygenation is for 4 min or till achievement of peripheral oxygen saturation greater than 95% with a face mask that will be connected to the oxygen port at 10 L/min. During the direct laryngoscopy there will be no insufflation of oxygen through nasal cannula or face mask.
Data collection:
Study Design
- Study Type
- Interventional
- Allocation
- Randomized
- Intervention Model
- Parallel
- Primary Purpose
- Prevention
- Masking
- None
Eligibility Criteria
- Ages
- 18 Years to — (Adult, Older Adult)
- Sex
- All
- Accepts Healthy Volunteers
- No
Inclusion Criteria
- •Adult patients (18 years and above) requiring endotracheal intubation in the emergency department.
- •Intubation performed by the emergency medicine physician who are post graduate trainee year IV and above. The year IV and above cut off is taken because at this time the trainees have done more than 20 endotracheal intubations. The operators are assessed through direct supervision and confirmation through filing of their procedural log books
Exclusion Criteria
- •Supervisor or operator feels specific intra-procedural oxygenation technique will be required.
- •Patients presenting with cardiac arrest
- •Pregnant patients (as the patients are at risk of aspiration and high oxygen delivery can have bad outcomes on the fetus)
- •Patients with 'Do not resuscitate' order.
- •Morbidly obese on assessment as such patient may need pre intubation preparation of the head side and more controlled settings.
- •Patient who are shifted from another hospital post intubation
- •Patients with interstitial lung disease or lung tumor
- •Neck trauma (expanding neck hematoma)
- •Neck and Oral cavity cancers, or patients with cancers of the neck and oral cavity who have undergone surgery, post radiation of the neck and oral cavity cancers.
- •Pulse oximetry <90% in ambient air.
- •Body mass index > 35kg/m2
Outcomes
Primary Outcomes
Lowest noninvasive oxygenation value
Time Frame: Within 3 hours, beginning from the administration of the sedation or the neuromuscular blocker till the placement of the endotracheal tube
The lowest noninvasive oxygenation value in any time between administration of sedation and/or neuromuscular blockade to successful endotracheal intubation
First pass success rate
Time Frame: With in 3 hours of the start of procedure for placement of endotracheal tube
Single successful attempt for the placement of endotracheal tube in the trachea during direct laryngoscopy and subsequent confirmation.
Secondary Outcomes
- Nonhypoxia complications(6 hours starting from the endotracheal tube placement.)
- Tube malposition(6 hours starting from the endotracheal tube placement.)
- Safe Apnea Time(With in 3 hours beginning from the administration of the sedation and or neuromuscular blockade drug to the placement of the endotracheal tube)
- Direct laryngoscopy grades(During the endotracheal tube placement)
Investigators
Shahan Waheed
Principal investigator and Consultant Emergency Medicine
Aga Khan University Hospital, Pakistan
