Personalization of CM Injection Protocols in Coronary Computed Tomographic Angiography

Maastricht University Medical Center1 个研究点 分布在 1 个国家目标入组 327 人开始时间: 2017年4月11日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
327
试验地点
1
主要终点
Image quality

研究概览

简要总结

Cardiac computed tomography (CCT) is one of the standard non-invasive imaging techniques allowing imaging of the heart and coronary arteries with a high temporal and spatial resolution. The high sensitivity and negative predictive value (NPV) of coronary CT angiography (CCTA) make it a valuable tool in the assessment of coronary artery disease (CAD) in patients with low to intermediate risk for CAD, especially to rule out CAD. This risk stratification can be done with help of multiple different risk-calculators (e.g. the updated Diamond-Forrester model by Genders et al. 2012). These calculators take different variables into account, e.g. advanced age, gender, blood pressure, diabetes mellitus (DM), lipid profile and smoking.

The aim of CCTA is a high diagnostic accuracy, which depends on both optimal intravascular enhancement (in Hounsfield Units; minimal 325 HU) and contrast-to-noise ratio (CNR). Optimal intravascular enhancement and CNR depend on different factors such as scan technique (e.g. tube voltage, tube potential), parameters of the administered contrast material (CM) and patient related factors (e.g. cardiac output (CO), body weight (BW)).

Patients with cardiac diseases often have multiple risk factors for developing contrast induced nephropathy (CIN), e.g. diabetes mellitus, advanced age, hypertension and chronic kidney disease. Although the relationship between CTA and CIN has recently come to discussion (AMACING trial; Nijssen et al. 2017), it is still desirable to minimise the CM volume used in these patients. One method to reduce the CM volume is to personalise the injection protocols. The personalisation of injection protocols to the individual patient is gaining more attention in the field of CT imaging. The goal is to individualise the injection protocols to a level, where the patient only receives the minimal amount of CM needed to acquire a diagnostic scan, while maintaining a diagnostic image quality. Many techniques are available and have been studied, e.g. adjustment of CM volume to scan protocol, CO, lean body weight (LBW) and BW.

However, no data is available on which of these is the most beneficial method for the personalisation of CM injection protocols. Therefore, the aim of this study is to assess the performance of three different personalized injection protocols (based on CO, LBW and BW) in CCTA with regard to image quality in comparison to previously used protocols in our department. We hypothesize that the personalized injection protocols will be non-inferior, provide a homogenous coronary enhancement (less non-diagnostic scans) in patients, and will account for a reduction of CM volume in our department in comparison to the previously used protocols.

详细描述

Cardiac diseases still are the leading cause of death in the western world. Besides the high mortality of the cardiac disease itself, recent studies have shown an increasing evidence of the prognostic value of cardiac diseases, particularly coronary artery disease (CAD), in a broad variety of other diseases. Especially in patients with oncological pathologies undergoing radiotherapy or lung resection surgery [Ambrogi et al. 2003; Kanzaki et al. 2017; Khakoo et al. 2008; Basacaraju et al. 2002; Fajardo et al. 1972]. Cardiac computed tomography angiography (CCTA) is one of the standard non-invasive imaging techniques allowing imaging of the heart and coronary arteries with a high temporal and spatial resolution. The high sensitivity and negative predictive value (NPV) of CCTA make it a valuable tool in the assessment of CAD. Especially to rule out CAD in patients with low to intermediate risk for CAD [Hendel et al. 2006; Goldstein et al. 2011; Budoff et al. 2008; Meijboom et al. 2008; Roffi et al. 2016].

The aim of CCTA is to achieve a high diagnostic accuracy, which depends on both optimal intravascular enhancement (in Hounsfield Units (HU); minimal 325 HU) and contrast-to-noise ratio (CNR). Optimal intravascular enhancement and CNR depend on multiple factors, such as scan technique (e.g. tube voltage (kV) and tube potential), parameters of the administered contrast material (CM) (e.g. concentration, flow rate) and patient related factors (e.g. body weight (BW), heart rate or cardiac output [CO]) [Bae et al. 2004; Awai et al. 2004]. Dedicated CT protocols are necessary to image the heart and the coronary arteries. These protocols require a correlation to the patient's electrocardiogram (ECG) in order to minimize cardiac motion and deliver a sharp image of the heart and coronary arteries. Depending on the heart rate of the patient, the scan can either be a prospectively ECG-triggered high-pitch or adaptive sequence, or retrospectively ECG-gated helical scan.

Patients with cardiac diseases often have multiple risk factors for developing contrast induced nephropathy (CIN), e.g. diabetes mellitus (DM), advanced age, hypertension, cardiovascular disease and chronic kidney disease. Although the relationship between CTA and CIN has recently come to discussion (AMACING trial; Nijssen et al. 2017), it is still desirable to minimise the CM volume used in these patients. Multiple strategies have been studied to reduce CM volume in CTA imaging [Kok et al 2016; Kok et al. 2015; Kok et al. 2016; Kok et al. 2016, Mihl et al. 2016; Seehofnerova et al. 2015; Hendriks et al. 2016]. For instance, lowering tube voltage to achieve a higher attenuation, the latter explained by the fact that mean photon energy of lower tube voltage settings in the x-ray beam moves closer to the K-edge of iodine (33.2 keV).

The personalisation of injection protocols to the individual patient is gaining more attention in CT imaging, and the goal is to individualise the injection protocols to a level, where the patient only receives the minimal amount of CM needed to make a diagnostic scan with a diagnostic image quality. Besides the techniques mentioned above, other techniques are possible, e.g. adjustment according to patients CO, lean body weight (LBW), and BW.

Both blood volume and CO increase with an increasing BW. When CO increases, the distribution of CM is also increased. On one hand this results in a fastened test bolus arrival, on the other hand in a decreased and shortened intravascular attenuation profile (in comparison to a decreased CO) [Bae KT 2010]. Therefore, both timing and CM volume can be adjusted to CO in order to achieve a similar intravascular attenuation profile.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Supportive Care
盲法
Double (Investigator, Outcomes Assessor)

盲法说明

All investigators who assess the image quality will be blinded to the assigned contrast media protocol. Only the technicians who complete the scan and injection protocol will be unblinded for the contrast media protocol chosen.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients referred for CCTA;
  • •Age > 18 years;
  • •Informed consent obtained.

排除标准

  • •Inability to perform a breath hold for the expected scan time;
  • •Hemodynamic instability;
  • •Pregnancy;
  • •Renal insufficiency (defined as glomerular filtration rate (GFR) < 30 mL/min);
  • •Iodine allergy;
  • •Age < 18 years;
  • •Absence of informed consent.

研究组 & 干预措施

Body Weight (BW)

Active Comparator

Patients referred for CCTA in this group receive a personalised contrast media protocol. Contrast media administration based on body weight.

干预措施: Contrast media administration (Other)

Cardiac output (CO)

Active Comparator

Patients referred for CCTA in this group receive a personalised contrast media protocol. Contrast media administration based on cardiac output.

干预措施: Contrast media administration (Other)

Lean Body weight (LBW)

Active Comparator

Patients referred for CCTA in this group receive a personalised contrast media protocol. Contrast media administration based on Lean Body Weight.

干预措施: Contrast media administration (Other)

Control group

No Intervention

Patients in this group will be included retrospectively and have received the standard CM injection protocol previously used in our department.

结局指标

主要结局

Image quality

时间窗: 1 year

To evaluate the performance of the individualised injection protocols in CCTA, with regard to intravascular attenuation (minimal 325 HU) and compare them with the control group (non-inferiority).

次要结局

  • Coronary artery disease(1 year)
  • Objective image quality(1 year)
  • subjective image quality(1 year)

研究者