跳至主要内容
临床试验/NCT07182487
NCT07182487已完成不适用

Relationship Between Postural Sway of Trunk and Upper Extremity Functional Skills in Patients With Parkinson's Disease(pwPD)

Kahramanmaras Sutcu Imam University1 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2025年4月30日最近更新:

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
80
试验地点
1
主要终点
The Gyko Device for postural truk stability

研究概览

简要总结

Parkinson's disease (PD) is the second most common neurodegenerative disease, characterized clinically by motor and non-motor symptoms, including bradykinesia, resting tremor, and/or rigidity. Among the motor deficits observed in PD, decreased postural control often results in decreased balance. Furthermore, losses in many upper extremity and manual skills are also observed in PD. Loss of postural control is one of the key motor symptoms observed in the advanced stages of PD, increasing the risk of falls. Analysis of postural control deficits is critical for assessing disease progression and treatment planning in PD. In this context, gyroscope-based motion analysis systems are used as a reliable method for assessing trunk sway.Sensory deficits, such as decreased spatial and temporal tactile discrimination thresholds in the fingertips, are also observed in PD. Reaching and grasping deficits are more common when patients have significant difficulty initiating movements toward a target. These patients exhibit deficits in manipulating the hand relative to object geometry. A loss of coordination between reach and grasp timing is observed. These patients generally rely on visual cues to control movement. They experience difficulties in optimal object manipulation due to difficulties planning finger placement.Studies have shown a strong relationship between postural control and fine motor functions. For high-quality distal movement, better proximal stabilization is necessary. During upper extremity functions, the body's center of gravity must shift with arm movements, allowing adaptation to changing gravity. Good trunk control is essential for this dynamic process of maintaining balance. Studies examining this link between trunk control, balance, and hand functions are available in the literature. Among these studies conducted in diverse populations, studies involving PD are very few. In light of this information, our study was designed to investigate the relationship between postural trunk sway and hand dexterity in PD. Therefore, the aim of this study was to determine the relationship between postural sway and upper extremity functional abilities in PD.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
40 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Healthy individuals aged 40-75 years, diagnosed with idiopathic PD according to the UK Parkinson's Disease Association Brain Bank criteria by a specialist neurologist, with a Modified Hoehn & Yahr (m-HY) scale stage ≤4, and with a Mini Mental State Examination score of ≥22 for those with training and ≥18 for those without training, and with no known disease, volunteered to participate in the study.
  • Individuals with no other known neurological and/or systemic disease
  • Individuals without any upper extremity contractures

排除标准

  • Individuals with severe balance and walking difficulties
  • Individuals with diagnosed and/or treated psychiatric illnesses who are considered unable to complete the required tests
  • Those taking neuroleptic medications or antidepressants
  • Individuals with orthopedic conditions that interfere with manual dexterity tests, such as severe dyskinesia, carpal tunnel syndrome, tendon injuries, or finger amputations; rheumatological diseases such as rheumatoid arthritis and osteoarthritis; and individuals with any neurological disease other than PD

结局指标

主要结局

The Gyko Device for postural truk stability

时间窗: first day of the assessment

This device, manufactured by Mikrogate and manufactured in Italy, is used as a portable inertial measurement unit for motion analysis and postural stability assessment. A sensor placed on a sling is used to analyze the displacement of the patient's center of gravity using a computer. The patient is asked to walk for 30 seconds. The data collected includes postural data such as sway length and area, sway excursion speed, and sway frequency. Studies have shown that the device has high absolute and relative reliability and provides measurements consistent with other validation methods . The device's ease of use and portability make it preferred in clinical and sports settings. Furthermore, the data accuracy it provides across different ground conditions and movement patterns has contributed to its widespread acceptance.

The 9-Hole Peg Test (DDPT)

时间窗: Day 1

The 9-Hole Peg Test (DDPT) is a validated test for PD that measures manual dexterity in seconds based on performance (21). The test material consists of nine standard-sized small rods and a nine-hole platform on which to place them. The test will be administered with the patient in a sitting position. The patient will be asked to place nine rods in the round compartment of the box as quickly as possible into the holes of the box, starting from the edge farthest from the compartment and immediately withdraw them from the edge closest to the compartment. The test will begin with the dominant hand, and the time will be measured with a stopwatch, starting when the hand touches the rods and ending when the last rod is placed in the box. The same procedure will be applied to the other hand. In this study, the arithmetic mean of the test times, repeated twice, will be recorded separately for each hand.

次要结局

  • Sosyodemographic form(Day 1)
  • Modified Hoehn & Yahr (m-HY) scale(Day 1)
  • Unified Parkinson's Disease Rating Scale (UPDRS)(Day 1)
  • Mini Mental State Examination(MMSE)(Day 1)

研究者

发起方
Kahramanmaras Sutcu Imam University
申办方类型
Other
责任方
Principal Investigator
主要研究者

Hatice Adiguzel

Associate Professor

Kahramanmaras Sutcu Imam University

研究点 (1)

Loading locations...

相似试验

Postural Sway of Trunk and Upper Extremity... | 临床试验