临床试验/CTRI/2019/05/019204
CTRI/2019/05/019204尚未招募未知

Comparison of the New Elisar Fast Algorithm with Swedish Interactive thresholding Algorithm fast

Dr Amar Agarwal0 个研究点目标入组 0 人开始时间: 待定最近更新:

试验速览

阶段
未知
状态
尚未招募
发起方

研究概览

简要总结

暂无简介。

研究设计

研究类型
Observational

入排标准

入选标准

  • 1.Cup disc ratio less than 0.5 (intraocular difference of 0.2 mm)
  • 2.IOP <21 mmHg (intraocular difference less than 3 mmHg)(10).
  • 3.The normal result of Glaucoma Hemifield test in HFA 30-2 SITA fast
  • Glaucoma and non-glaucomatous field loss:
  • 1. Glaucoma is defined as IOP greater than 21 mmHg or intraocular difference in IOP more than 3mmHg and Cup disc ratio more than 0.5, and the intraocular difference in a cup-disc ratio less than more than 0.2.
  • 2.A positive report of the SITA standard with Humphrey visual field analyzer.
  • 3. The best corrected visual acuity should be better than or equal to 6/12.
  • 4. Spherical correction should be < 5 D, Cylindrical correction should be < 3 D.

排除标准

  • 1. Fixation losses, false positive and false negative > 20% will be excluded from the study.
  • 2. The reports with significant lid artifact will be excluded from the study. The lid artifact is defined as the density of the defect greater than or equal to 11 decibels (dB) for a single test location or greater than or equal to 7 dB for two adjacent test locations according to the pattern deviation from age-corrected normal values. Second, the defect must involve loci between 20° and 30°.
  • 3. Patients who had undergone ocular surgeries (other than cataract surgery), patients with ocular disease, amblyopia, neurological disorders will be excluded from the study.
  • 4. Patients using a miotic drug will be excluded from the study.