AS-OCT Evaluation of Iridocorneal Angle of Patients of Angle Closure Glaucoma After Phacoemulsification
- Conditions
- Glaucoma, Angle-Closure
- Interventions
- Device: AS-OCTProcedure: YAG laser PI
- Registration Number
- NCT05332665
- Lead Sponsor
- Minia University
- Brief Summary
Evaluation of the effect of phacoemulsification and YAG Laser peripheral iridotomy on the anterior chamber angle anatomic parameters in PACG eyes, using anterior segment optical coherence tomography (SS ASOCT) device
- Detailed Description
The recent treatment of ACG is phacoemulsification in patients of acute attack with YAG laser iridotomy in the other eye.
The AS-OCT will be used for evaluation of the angle of the anterior chamber parameters in both eyes after phacoemulsification and YAG laser peripheral iridotomy.
Follow up of AS-OCT will be done 1,3,6 months after surgery and we will compare results in each eye and between both eyes.
.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 15
- patients with acute attack of angle closure glaucoma in one eye.
- Patients fit for phacoemulsification
- 1- Patients with history of any intraocular surgery. 2- Patients with history of refractive surgery. 3- Patients with diabetic retinal vasculopathy or retinal detachment. 4- Patients with chronic angle closure glaucoma, open angle glaucoma or 2ry glaucoma
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Trabecular iris space area (TISA) 500 YAG laser PI TISA 500 was measured as an area bounded anteriorly by the AOD 500, posteriorly by a line drawn from the scleral spur perpendicular to the plane of the inner scleral wall to the opposing iris, superiorly by the inner corneoscleral wall, and inferiorly by the iris surface Angle opening distance (AOD) AS-OCT The AOD measured as perpendicular distance between anterior iris surface and point at trabecular meshwork at 500 μm anterior to the scleral spur Trabecular iris space area (TISA) 500 AS-OCT TISA 500 was measured as an area bounded anteriorly by the AOD 500, posteriorly by a line drawn from the scleral spur perpendicular to the plane of the inner scleral wall to the opposing iris, superiorly by the inner corneoscleral wall, and inferiorly by the iris surface Angle opening distance (AOD) YAG laser PI The AOD measured as perpendicular distance between anterior iris surface and point at trabecular meshwork at 500 μm anterior to the scleral spur Anterior chamber depth (ACD) AS-OCT The ACD was measured as the perpendicular distance from the corneal endothelium at the corneal apex to the anterior lens surface Anterior chamber depth (ACD) YAG laser PI The ACD was measured as the perpendicular distance from the corneal endothelium at the corneal apex to the anterior lens surface
- Primary Outcome Measures
Name Time Method IOP up to 6 months mmhg
- Secondary Outcome Measures
Name Time Method Corneal endothelial count up to 6 months CD per mm2
Trial Locations
- Locations (1)
mohamed Mahmoud
🇪🇬Minia, El Minia, Egypt