MedPath

AS-OCT Evaluation of Iridocorneal Angle of Patients of Angle Closure Glaucoma After Phacoemulsification

Conditions
Glaucoma, Angle-Closure
Interventions
Device: AS-OCT
Procedure: YAG laser PI
Registration Number
NCT05332665
Lead Sponsor
Minia University
Brief Summary

Evaluation of the effect of phacoemulsification and YAG Laser peripheral iridotomy on the anterior chamber angle anatomic parameters in PACG eyes, using anterior segment optical coherence tomography (SS ASOCT) device

Detailed Description

The recent treatment of ACG is phacoemulsification in patients of acute attack with YAG laser iridotomy in the other eye.

The AS-OCT will be used for evaluation of the angle of the anterior chamber parameters in both eyes after phacoemulsification and YAG laser peripheral iridotomy.

Follow up of AS-OCT will be done 1,3,6 months after surgery and we will compare results in each eye and between both eyes.

.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
15
Inclusion Criteria
  • patients with acute attack of angle closure glaucoma in one eye.
  • Patients fit for phacoemulsification
Exclusion Criteria
  • 1- Patients with history of any intraocular surgery. 2- Patients with history of refractive surgery. 3- Patients with diabetic retinal vasculopathy or retinal detachment. 4- Patients with chronic angle closure glaucoma, open angle glaucoma or 2ry glaucoma

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Trabecular iris space area (TISA) 500YAG laser PITISA 500 was measured as an area bounded anteriorly by the AOD 500, posteriorly by a line drawn from the scleral spur perpendicular to the plane of the inner scleral wall to the opposing iris, superiorly by the inner corneoscleral wall, and inferiorly by the iris surface
Angle opening distance (AOD)AS-OCTThe AOD measured as perpendicular distance between anterior iris surface and point at trabecular meshwork at 500 μm anterior to the scleral spur
Trabecular iris space area (TISA) 500AS-OCTTISA 500 was measured as an area bounded anteriorly by the AOD 500, posteriorly by a line drawn from the scleral spur perpendicular to the plane of the inner scleral wall to the opposing iris, superiorly by the inner corneoscleral wall, and inferiorly by the iris surface
Angle opening distance (AOD)YAG laser PIThe AOD measured as perpendicular distance between anterior iris surface and point at trabecular meshwork at 500 μm anterior to the scleral spur
Anterior chamber depth (ACD)AS-OCTThe ACD was measured as the perpendicular distance from the corneal endothelium at the corneal apex to the anterior lens surface
Anterior chamber depth (ACD)YAG laser PIThe ACD was measured as the perpendicular distance from the corneal endothelium at the corneal apex to the anterior lens surface
Primary Outcome Measures
NameTimeMethod
IOPup to 6 months

mmhg

Secondary Outcome Measures
NameTimeMethod
Corneal endothelial countup to 6 months

CD per mm2

Trial Locations

Locations (1)

mohamed Mahmoud

🇪🇬

Minia, El Minia, Egypt