MedPath

Three-dimensional Ultrasonography Thyroid Volume Measurement.

Not Applicable
Conditions
Thyroid
Graves Disease
Thyroid Adenoma
Thyroid Diseases
Thyroid Goiter
Thyroid Cancer
Interventions
Device: BK 5000 Ultrasound Machine
Registration Number
NCT05510609
Lead Sponsor
Rigshospitalet, Denmark
Brief Summary

The purpose of this clinical trial is to investigate the accuracy of applying three-dimensional ultrasound on thyroid gland patients when determining a gland volume.

The method will be compared to conventional b-mode ultrasound where three axis measurements (length, width, and depth) are evaluated in the ellipsoid model.

The three dimensional (3D) method is utilizing optical tracking connected to the ultrasound image to form cross-sectional imaging. Patients enrolled in the study are set for complete thyroidectomies enabling a true volume of the gland by water displacement after excision.

The aim is to find if this 3D method is more accurate in volume estimation than the ellipsoid model.

Detailed Description

Not available

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
17
Inclusion Criteria
  • Patients referred to Rigshospitalet to undergo a complete thyroidectomy including patients with previous hemithyroidectomy
  • Adults, 18 or older.
  • Ability to give written informed consent
Exclusion Criteria
  • Thyroid glands that are too enlarged causing visualization/measurement impairment with ultrasonography.
  • Thyroid cancer with preoperative suspected extracapsular spread.
  • Thyroids or lymph nodes that need frozen section examination.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
ThyroidectomyBK 5000 Ultrasound MachinePatients set for total thyroidectomy incl. functional total thyroidectomies.
Primary Outcome Measures
NameTimeMethod
Thyroid volume1 hour

Obtaining thyroid volume with 2D ultrasound (length x Width x depth\*(Pi/6)) and 3D ultrasound with optical tracking and comparing the respective methods with a reference volume. Water displacement being gold standard for reference volume.

Secondary Outcome Measures
NameTimeMethod
Shrinkage in gland after excision30 minutes

Looking af the change in volume invivo vs exvivo w. 2D and 3D ultrasound

Interobserver variability2 hours

Variation in volume estimation when delineating ultrasound images.

Trial Locations

Locations (1)

Rigshospitalet

🇩🇰

Copenhagen, Capital, Denmark

© Copyright 2025. All Rights Reserved by MedPath