Characterization of an Optically Pumped Magnetometer (OPM) Magnetoencephalography (MEG) Array
- Conditions
- Normal Physiology
- Interventions
- Device: SQUID MEGDevice: OPM MEG
- Registration Number
- NCT04950309
- Lead Sponsor
- National Institute of Mental Health (NIMH)
- Brief Summary
Background:
Brain activity produces magnetic fields. These fields can be measured outside the head. Existing technology, called MEG, measures these fields. Researchers are testing a new type of magnetic field sensor called OPM. They hope it can help pinpoint with very high accuracy where brain activity is generated.
Objective:
To develop and test a new type of sensor for measuring the magnetic fields produced by brain activity.
Eligibility:
Healthy people ages 18-65 who had a magnetic resonance imaging (MRI) scan under protocol 17-M-0181.
Design:
Participants may be asked to complete sessions on both the traditional MEG instrument and the OPM array.
For the MEG, 3 small coils will be placed on the participant s face with tape. Their head will be positioned inside the MEG device.
For the OPM, sensors are housed in a 3d printed array. The sensors will be attached to a cap placed on the participant s head.
For both scans, participants will be seated in a chair inside a magnetically shielded room. They may complete several tasks. In one task, plastic cells will be placed on their fingers. Puffs of air will be sent to these cells, which will stimulate the sense of touch. Other tasks may include the following stimuli: visual (such as checkerboards), auditory (such as beeps and tones), or language (words and letters).
Researchers may also obtain recordings while they stimulate the nerve in the participant s forearm using electrical current in small electrodes.
Participation is expected to last for 1 day. Additional optional scans may be offered for up to 1 year....
- Detailed Description
Study Description:
This protocol is a technical development protocol to characterize an optically pumped magnetometer (OPM) array used for measuring magnetic brain signals. We hypothesize that with our OPM arrays, we can achieve similar or better spatial resolution to that of a conventional MEG system.
Objectives:
Primary Objective 1: To fully characterize the performance of an OPM MEG array.
Primary Objective 2: To demonstrate that the OPM system can produce somatotopic maps accurately differentiating receptive fields of each finger. If successful, we will additionally determine if the system can differentiate receptive fields of each phalanx.
Endpoints:
Primary Endpoint: OPM array characterization parameters including signal to noise, sensitivity, bandwidth, and spatial
resolution, and comparison to similar parameters acquired on a standard SQID system.
Secondary Endpoint: Somatotopic representations of the digits of the hand
Recruitment & Eligibility
- Status
- RECRUITING
- Sex
- All
- Target Recruitment
- 75
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description OPM Array studies SQUID MEG Testing of a final 49-61 channel OPM MEG system and any interim arrays OPM Array studies OPM MEG Testing of a final 49-61 channel OPM MEG system and any interim arrays
- Primary Outcome Measures
Name Time Method array characterization metrics throughout protocol At each phase of array construction characterization parameters including signal to noise, sensitivity, bandwidth, and spatial resolution will be measured.
- Secondary Outcome Measures
Name Time Method Somatotopic representations throughout protocol Somatotopic representations of the digits of the hand, potentially differentiating the individual phalanx of each finger.
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.
Trial Locations
- Locations (1)
National Institutes of Health Clinical Center
🇺🇸Bethesda, Maryland, United States