To assess the clinical procedure impact of PURE-EP signals of interest vs. a standard recording system in a Redo AF population

研究概览

简要总结

This study is a sub study of the Pure EP 2.0 trial. In a redo atrial fibrillation population, this study is designed to collect pulmonary vein signals pre and post ablation therapy, along with other non-pulmonary vein signals of interest during a redo ablation procedure. These signals are later evaluated for clinical relevance and impact on the procedure.

详细描述

Cardiac electrophysiologists rely on the display of electrograms when performing EP studies and catheter ablations in patients with arrhythmias. To achieve effective outcomes without complications, it is vital that the recording system enables the recognition of clearly abnormal (scared myocardium) and normal electrical signals.

In a redo Atrial Fibrillation (AF) procedure, the patient had previously undergone an AF ablation procedure, but is still having AF episodes, which can be life threatening and have been shown to lead to strokes. Since the original AF procedure involved burning or freezing of myocardial tissue, this is now additional scar tissue and may cause more complex electrograms and intracardiac signals.

In this sub study, both the PURE EP™ system and the GE Cardiolab system will be running and recording signals during the entire procedure, with one of the systems displayed on the screen in the procedure room to guide the physician's decision-making. Even numbered subjects will be PURE EP™ guided and odd numbered subjected will be GE CardioLab guided. All other aspects of the procedure will proceed per standard of care. The study will be collect pulmonary vein signals pre and post ablation therapy, along with other non-pulmonary vein signals of interest during a redo ablation procedure.

After the physician has completed ablation treatment, matching signals of interest will be extracted from both the PURE EP™ system and the GE Cardiolab recording system as described in the main study. At a later date, a blinded electrophysiologist reviewer will evaluate the signals from both systems with a focus on tissue viability signals and the impact on the procedure. The survey results will then be compared to see the differences in clinical procedure decision-making based on the signal samples.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patients undergoing scheduled elective cardiac ablation procedures who have signed an informed consent
  • •Patients who are > 18 years of age.
  • •Patients undergoing a repeat elective cardiac AF Procedure

排除标准

  • •A complex arrhythmia secondary to a reversible cause
  • •Significant congenital anomaly or medical problem that in the opinion of the investigator would preclude enrollment in this study.
  • •Any cardiac surgery within the past 60 days (2 months) (includes PCI)
  • •Concurrent enrollment in a study evaluating another device or drug
  • •A complex arrhythmia secondary to electrolyte imbalance, thyroid disease or non-cardiac issue
  • •Presence of intra-cardiac thrombus or myxoma, interatrial baffle or patch, tumor or other abnormality that precludes catheter introduction or manipulation.
  • •Presence of a condition that precludes vascular access.
  • •Women of child baring potential whom are pregnant, lactating, or planning to become pregnant during the course of the clinical investigation.
  • •Active illness or active systemic infection or sepsis.

结局指标

主要结局

To assess the clinical procedure impact of PURE-EP signals of interest vs. a standard recording system in a Redo AF population

时间窗: 6 months

The signals of interest will undergo a homogenization process to remove all identifiers of the system used. At a later time, a blinded electrophysiologist reviewer will evaluate the signals for clinical relevance and procedural impact from both systems using the same Blinded Signal Assessment Form. The Blinded Assessment Form results will be compared to both each other and what was done at the procedure.