MedPath

TRANSFORM OCT TRiple Assessment of Neointima Stent FOrmation to Reabsorbable polyMer With Optical Coherence Tomography

Phase 4
Conditions
Coronary Artery Lesions
Interventions
Device: EES SYNERGY™
Device: ZES, RESOLUTE Integrity™
Registration Number
NCT01972022
Lead Sponsor
A.O. Ospedale Papa Giovanni XXIII
Brief Summary

First prospective randomized controlled study to evaluate in an 'all-comers' population with coronary artery disease whether treatment with a novel everolimus eluting stent (EES) with a biodegradable polymer is superior to a durable polymer zotarolimus eluting stent (ZES), with respect to the long term vascular response to treatment These data are important to ascertain the superiority of a new generation DES with bioabsorbable polymer coating to reduce the long term development of in-stent neoatherosclerosis.

Detailed Description

During the last decade a considerable clinical experience has been accumulated with the use of drug eluting coronary stents with durable polymers, that permanently cover the metallic stent scaffold, allowing the local delivery of anti-restenotic agents. However durable polymers have been associated with an increased risk of late and very late stent thrombosis and the anticipated development of in stent neo-atherosclerosis. Since permanent polymer coatings may have pro-inflammatory effects, with delayed healing and prolonged endothelial dysfunction, current research on DES has focused on the use of biodegradable polymer coatings, which disappear after a short period of drug-release (3-4 months). Current clinical guidelines recommend at least 6-12 months of dual antiplatelet therapy (DAPT) after DES implantation,in order to prevent ST. Recent data obtained by pooled analyses of ZES, support a significant reduction of the DAPT to the same range used with bare metal stents. The substantial delays in DES healing observed from multiple human pathology series and in-vivo studies using Optical Coherence Tomography (OCT) were not assessed as risk factors for prolonged used of DAPT. However different patient cohorts might have different responses to stent implantation. In addition, there is no comparative evidence on long term development of neo-atherosclerosis in bioabsorbable versus permanent polymer DES. OCT allows precise assessment of stent strut apposition and coverage and accurate measures of different tissue components of neoatherosclerosis. This study is the first attempting to characterize the early and late vascular responses to novel bioabsorbable polymer EES (SYNERGY™) compared with a permanent polymer benchmark novel generation ZES (RESOLUTE INTEGRITY™) .The stent comparator has been selected due to the large use across the interventional cardiology community and the recent approval from European Regulators Authorities to update the CE (Conformité Européenne) mark labeling to only one-month duration of dual anti-platelet therapy.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
90
Inclusion Criteria
  1. Subject is ≥18 years of age;
  2. Subject has stable angina or acute coronary syndrome (including acute myocardial infarction) with evidence of coronary ischemia and de novo atherosclerotic coronary artery disease in multiple vessels with an indication for stent implantation;
  3. Target lesion stenosis is ≥ 70% (visual estimate)
  4. All target lesions require treatment with stents having diameters from 2.25 mm to 4.0 mm (visual estimate)
  5. Target lesion length ≥10 mm and ≤50 mm for each target lesion(s)
  6. Subject must sign Ethics Committee approved informed consent prior to undergoing any study specific procedure;
  7. Subject must be willing and able to comply with specified follow-up schedule.
Exclusion Criteria
  1. Unprotected left main coronary disease;
  2. Chronic total occlusion;
  3. Severe calcified target lesion(s) which cannot be, in the investigator's opinion, successfully treated;
  4. Significant angulation in the target vessel that, in the Investigator's opinion, may preclude stent delivery and deployment;
  5. Bifurcation disease involving a side branch ≥ 2.5 mm in diameter;
  6. Restenotic lesions;
  7. Target lesion(s) within a coronary bypass graft (e.g., saphenous vein or arterial graft);
  8. In the Investigator's opinion, the lesion is not suitable for stenting or OCT imaging (e.g. extreme tortuosity, very distal lesions).
  9. Documented left ventricular ejection fraction ≤30%;
  10. Serum creatinine > 2.0 mg/dl at the time of treatment;
  11. Recipient of heart transplant;
  12. Subject with malignancies or other comorbidities (i.e. severe liver, renal, pulmonary, pancreatic disease) with life expectancy less than 18 months or that may results in protocol non-compliance;
  13. Known bleeding or hyper-coagulable disorder;
  14. Known allergy to stent components or any antiplatelet recommended drug
  15. Planned medical or surgical procedures requiring modification of DAPT regimen within 3 months after the index procedure;
  16. Women of childbearing potential without negative pregnancy test within 7 days before enrollment
  17. Currently participating in an investigational study that has not completed the primary endpoint or that clinically interferes with the study endpoints

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
EES SYNERGY™EES SYNERGY™coronary artery lesions treated with Bioabsorbable Polymer EES
ZES, RESOLUTE Integrity™ZES, RESOLUTE Integrity™coronary artery lesions treated with ZES, RESOLUTE Integrity™ stent system
Primary Outcome Measures
NameTimeMethod
percentage of frames with in stent-lipid laden neointima, neovascularization, calcification and thin-cap fibro-atheroma (TFCA)18 months

OCT finding of neoatherosclerosis, counted as percentage of frames with in stent-lipid laden neointima, neovascularization, calcification and thin-cap fibro-atheroma (TFCA) (18 month primary end-point)

length of consecutive frames with uncovered struts3 and 18 months

OCT derived maximum length of consecutive frames with uncovered struts in the two stent arms at 3 and 18 month (3 month primary end-point and 18 months co-primary end-points)

Secondary Outcome Measures
NameTimeMethod
percent well apposed struts at implant without neointima3 and 18 months

OCT derived proportion of well apposed struts at implant without neointima (% uncovered struts) at 3 and 18 months

Acquired stent malapposition3 and 18 moths

Number and extent (max area-volume) of newly acquired malapposed struts at 3 and 18 months.

OCT derived abnormal intraluminal tissue3 and 18 months

Presence of any abnormal intraluminal protruding mass at 3 and 18 months

percentage OCT frames with uncovered struts3 and 18 months

Number/percentage of OCT frames with \> 30% uncovered struts at 3 and 18 months

Neointimal tissue thickness3 and 18 months

OCT calculated thickness of tissue covering stents at 3 and 18 months

OCT derived percentage of frames with mature neointima3 and 18 months

Percentage of frames with evidence of mature neointimal coverage in the two stent arms

OCT derived tissue heterogeneity in neointima deposition3 and 18 moths

Segmental tissue heterogeneity in neointima deposition across the entire stent length (as assessed by OCT tissue properties parameters - including normalized intensity, attenuation, tissue contrast) at 3 and 18 months

Trial Locations

Locations (1)

A.O. Ospedale Papa Giovanni XXIII

🇮🇹

Bergamo, Italy

© Copyright 2025. All Rights Reserved by MedPath