跳至主要内容
临床试验/NCT02265926
NCT02265926已完成不适用

Respiratory Consequences of N95-type Mask Usage in Pregnant Healthcare Workers - A Controlled Clinical Study

National University Health System, Singapore2 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2009年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
20
试验地点
2
主要终点
Minute Ventilation

研究概览

简要总结

The study aims to find out if usage of N95 type respirators affects respiratory parameters in pregnant women so as to provide guidance on N95 respirator usage in pregnant healthcare workers.

详细描述

The first phase of the study aims to determine the average workload of a nurse. In the second phase of the study, this workload is then translated to walking on a treadmill while pregnant subjects wore special masks open to air, then occluded with N95 mask materials.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
21 Years 至 40 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • Subjects had spontaneously conceived singleton pregnancies and were between 21 to 40 years old. Their hemoglobin levels were ≥11g/dL

排除标准

  • Any cardiorespiratory illness, influenza-like illness in the week prior to the trial, or any pregnancy-related complications such as gestational diabetes, hypertension, intrauterine growth restriction, placenta previa, ruptured membranes, or threatened preterm labor. Any neuromuscular conditions that would preclude them from using the treadmill.
  • Haemoglobinopathies.

结局指标

主要结局

Minute Ventilation

时间窗: 15 minutes

Participants wore a tight fitting mask (Hans Rudolph) that was attached to the metabolic cart through an air sampling tube. Inspired ambient air and expired air were channeled through a pneumotachometer that was attached to the front of the mask which calculated air volume by the rate of rotation of a rotor turbine located within it. The turbine had zero resistance to air flow and the rate of rotation of the turbine, sensed by infrared light within the pneumotachometer, corresponds directly to inspired and expired air volume for each breath. Multiple air samples from each expired-breath was drawn into the metabolic carts through a sampling line for the measurement of oxygen and carbon dioxide content by the respective gas sensors within the metabolic carts.

次要结局

  • Oxygen and carbon dioxide exchanged(15 minutes)

研究者

发起方
National University Health System, Singapore
申办方类型
Other
责任方
Principal Investigator
主要研究者

Pearl Tong

Associate Consultant

National University Health System, Singapore

研究点 (2)

Loading locations...

相似试验