跳至主要内容
临床试验/NCT03411876
NCT03411876已完成不适用

Effects of an Oxymizer Pendant Cannula Versus a Conventional Nasal Cannula During Endurance Shuttle Walk Test (ESWT) in Hypoxemic Patients With Idiopathic Pulmonary Fibrosis

Klaus Kenn1 个研究点 分布在 1 个国家目标入组 22 人开始时间: 2018年1月18日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
22
试验地点
1
主要终点
Endurance shuttle walk test distance

研究概览

简要总结

Aim of this study is to investigate the effects of an Oxymizer pendant nasal cannula in hypoxemic patients with idiopathic pulmonary fibrosis during walking.

详细描述

Patients will be recruited during an inpatient pulmonary rehabilitation program. They will perform three shuttle walk tests on three consecutive days (see below). While performing those tests, the patient's prescribed oxygen flow rate is applicated either through the conventional nasal cannula (CNC) or the Oxymizer.On the first day, patients perform an incremental shuttle walk test to determine maximum walking speed using a conventional nasal cannula.

On two consecutive days, patients will perform two endurance shuttle walk tests at 85% of the maximum incremental shuttle walk test speed. Supplemental oxygen will be provided via nasal cannula at the prescribed oxygen flow rate. Patients will be randomly assigned to perform one test with the Oxymizer and the other one with a conventional nasal cannula.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Treatment
盲法
Single (Outcomes Assessor)

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •firmed diagnosis of idiopathic pulmonary fibrosis
  • •indication for supplemental oxygen therapy during exercise
  • •referred to an inpatient rehabilitation program at the Schön Klinik Berchtesgadener Land

排除标准

  • •cardiovascular diseases that influence the patient's physical performance
  • •orthopedic comorbidities that prevent the patient from performing an incremental or endurance shuttle walk test
  • •carbon dioxide pressure above 45 mmHg at rest and ambient air

研究组 & 干预措施

First ESWT with Oxymizer, second ESWT with CNC

Experimental

Patients in this study arm first perform the first endurance shuttle walk test (ESWT) with the Oxymizer and the second ESWT with a conventional nasal cannula (CNC).

干预措施: Oxymizer® pendant nasal cannula (Device)

First ESWT with Oxymizer, second ESWT with CNC

Experimental

Patients in this study arm first perform the first endurance shuttle walk test (ESWT) with the Oxymizer and the second ESWT with a conventional nasal cannula (CNC).

干预措施: conventional nasal cannula (Device)

First ESWT with CNC, second ESWT with Oxymizer

Experimental

Patients in this study arm first perform the first endurance shuttle walk test (ESWT) with the CNC and the second ESWT with the Oxymizer.

干预措施: Oxymizer® pendant nasal cannula (Device)

First ESWT with CNC, second ESWT with Oxymizer

Experimental

Patients in this study arm first perform the first endurance shuttle walk test (ESWT) with the CNC and the second ESWT with the Oxymizer.

干预措施: conventional nasal cannula (Device)

结局指标

主要结局

Endurance shuttle walk test distance

时间窗: at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test

Distance patients walk during an endurance shuttle walk test

次要结局

  • heart rate(at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test)
  • carbon dioxide pressure(at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test)
  • oxygen saturation(at baseline, at isotime of endurance shuttle walk test and at the end (maximum 20 min) of endurance shuttle walk test)
  • breathing frequency(at baseline, at isotime of endurance shuttle walk test and at the end (maximal 20 min) of endurance shuttle walk test)
  • time to desaturation(From beginning of endurance shuttle walk test until the oxygen saturation reaches defined thresholds, or ESWT reaches maximum time frame of 20 minutes)

研究者

发起方
Klaus Kenn
申办方类型
Other
责任方
Sponsor Investigator
主要研究者

Klaus Kenn

Prof. Dr. med.

Schön Klinik Berchtesgadener Land

研究点 (1)

Loading locations...

相似试验