Hemodynamic Changes With Passive Leg Raising Maneuver in Patients Undergoing Arthroscopic Shoulder Surgery

Conditions
Arthroscopic Shoulder Surgery
Registration Number
NCT04152135
Lead Sponsor
Diskapi Teaching and Research Hospital
Brief Summary

After intubation of the patients who are undergoing arthroscopic shoulder surgery, plethysmographic waveform will be recorded with blood pressure, heart rate and end-tidal carbon dioxide values and inferior vena cava (IVC) diameter will be measured by ultrasound. New hemodynamic values will be measured after passive leg raising maneuver. Blood pressure, heart rate, end-tidal carbon dioxide values will be re-measured and plethysmographic waveform will be recorded after beach chair position for surgery.

Detailed Description

Patients aged between 18-65 years who are undergoing arthroscopic shoulder surgery will be examined. After giving detailed information, voluntary certificate will be taken from patients who accept to participate in the study. Heart rate, oxygen saturation and blood pressure values will be recorded by routine monitoring. After intubation of the patients, plethysmographic waveform will be recorded with blood pressure, heart rate and end-tidal carbon dioxide values and IVC diameter will be measured by ultrasound. New hemodynamic values will be measured after passive leg raising maneuver. Blood pressure, heart rate, end-tidal carbon dioxide values will be re-measured and plethysmographic waveform will be recorded after beach chair position for surgery.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
50
Inclusion Criteria
  • 18-65 years old patients,
  • The American Society of Anesthesiologists (ASA) physical status classification score 1-2,
  • Patients scheduled for arthroscopic shoulder surgery, intubated, sitting position
Exclusion Criteria
  • Patient refusal,
  • Patients with current heart and valve disease,
  • Patients with ASA 3-4 status,
  • Emergency cases

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
passive leg raising maneuver2 minutes

Head of bed at 0 degrees flat and both legs elevated to 45 degrees

vena cava inferior diameter2 minutes

Ultrasound equipment with convex probe will be used to measure IVC diameters of the patients in supine position.The IVC sagittal section is described with the probe in the area of subxiphoid. IVC diameters at the junction point of the IVC and right atrium (2cm caudal) are standardized measurement.

Secondary Outcome Measures
NameTimeMethod
Blood pressure2 minutes

non-invasive measurement, routine monitoring

Heart rate2 minutes

Routine monitoring

End-tidal CO22 minutes

Routine monitoring after intubation

plethysmographic waveform2 minutes

Routine monitoring