Prospective, Monocentric Study of the Interchangeability of Arterial Coagulation and Venous Coagulation, in the Context of Cardiac Surgeries Under Cardiopulmonary Bypass, Using the DMDiv Hemochron Signature Elite

Centre Hospitalier Universitaire, Amiens2 个研究点 分布在 1 个国家目标入组 201 人开始时间: 2023年6月7日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
201
试验地点
2
主要终点
Activated Clotting Time after using the Hemochron Signature Elite® medical device

研究概览

简要总结

Adequate coagulation measured using activated clotting (ACT) is important during vascular and cardiac surgeries. Unfractionated heparin is the most common anticoagulant used. For point of care testing, under supervision of biology department, the investigators use Hemochron Signature Elite®(HSE) (Werfen®-Barcelona Spain) to determine coagulation during cardiac surgery under Cardiopulmonary Bypass (CPB), with arterial or venous blood. The dosage of heparin varies according to this result, throughout the CPB. On the Connect Manager® software (Livanova®, Italy) which records all the data of a CPB, it is mandatory to inform, during an ACT, the sampling site in arterial or venous. The chemical compositions of arterial blood and venous blood are different (O2, Co2…) Even if the qualities of coagulation in vivo are identical, what happens when they are chemically analyzed using the medical device HSE ? Can we trust the results of this device to secure anticoagulation under CPB? Are the results affected by the sampling site? The objective of this study is to compare the reliability of hemostasis control , during cardiac surgery under cardiopulmonary bypass, for both venous and arterial blood. Effective and controllable anticoagulation is mandatory during cardiac surgeries under extracorporeal circulation. The monitoring of the effectiveness of heparin is carried out, in our center, using the Hemochron Signature Elite® (HSE) medical device, which measures the ACT (Activated Clotting Time). There is no comparative study between hemostasis of venous blood, versus arterial blood, with this point of care device.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients aged 18 and over,
  • undergoing conventional heart surgery under normothermic Cardiopulmonary Bypass (nadir 34°) (Aortic valve replacement, coronary artery bypass graft surgery, valve plasty, atrial septal defect, ventricular septal defect, intracardiac tumours, heart surgery, ascending aorta, combined surgery…)
  • They must be affiliated with Social Security in France, and have given their written consent.

排除标准

  • Minor Patients,
  • Emergency Cardiac Surgeries, Extracorporeal circulation in hypothermia, Cardiac surgery without CEC
  • Patients already included in a research protocol,
  • Patient under guardianship or curators or deprived of public law,
  • Patient with proven Heparin Induced Thrombopenia (HIT) not receiving heparin
  • Pregnant woman, breastfeeding or parturient

结局指标

主要结局

Activated Clotting Time after using the Hemochron Signature Elite® medical device

时间窗: day 1

次要结局

未报告次要终点