Prosthetic Modality and MBL
- Conditions
- Bone Loss
- Registration Number
- NCT07156110
- Lead Sponsor
- Studio Odontoiatrico Associato Dr. P. Cicchese e L. Canullo
- Brief Summary
The present study will test the effect of different prosthetic modalities on conical and internal hex connection implants, assessing the radiographic MBL changes after one year.
Consecutive patients fulfilling inclusion/exclusion criteria will enter the study. Once the implant is inserted, patients will be divided into three groups according to the time if their inclusion in the study.
Study groups (20 patients per group):
1. Group 1: Placing Lance Conical implant with a healing abutment. Three months later, after an impression, a screw-retained restoration will be seated using a Ti-Base abutment.
2. Group 2: Placing Lance+ (Internal Hex connection) implant with a healing abutment. Three months later, after an impression, a screw-retained restoration will be seated using a Ti-Base abutment.
3. Group 3: Placing Lance Conical implant together with Connect Abutment (tightened to 30 Ncm) with a Connect healing cap ("one time one abutment"). Screw retained restoration after 3 months.
Consecutive inclusion of patients - 1st- group 1, 2nd - group 2, 3rd - group 3 and vice versa.
Primary outcome variable: bone level changes 12 months post-loading
- Detailed Description
Actually, the histologic composition of the soft tissue around the prosthetic district was Indirectly clarified firstly in animal studies focused on biologic width re- establishment, now renamed supracrestal tissue attachment, which described the epithelial and connective components and the key role in the implant longitudinal maintenance they have (1). In fact, it was shown that the soft tissue morphogenesis in humans may occur in 8-12 weeks (2) This histologic structure is represented by a dense connective tissue with few fibroblasts and edondotelial cells isolated by a junctional epithelium indirectly connected to the abutment in the most coronal portion by a thin layer of proteoglycans and psudopodia (3).
Traditionally the Interaction between living cells and a biocompatible foreign material is mediated by some biological factors and could be associated with a mathematical equation Apparently, this is based on few variables generically represented by soft tissue patterns and biomaterial features (4). In fact, according to the basic science, the host tissue (intended both histologically and epigenetically), the biocompatible foreign material and the antagonist.
The tissue variable should be intended not only as its clinical appearance (thin vs thick), but overall as its INDIVIDUAL regenerative and inflammatory capability (which of course involves also the histologic aspect) (5) Changing our prospecting and focusing on the prosthetic variable, this should be intended not only as it is in its macro/micro and nano structure, but also as it is used in the prosthetic work flow In fact, the proximity of the prosthetic components to the connective tissues (mostly evident in case platform switching configuration) could allow the clinician during the healing period to actively influence soft tissue morphogenesis In fact, 2 weeks after reopening, traditional prosthetic work flow provides for healing abutment disconnection and impression taking (just at the peak of the first phases of wound healing) and two weeks there after new disconnections are required for try ins and definitive prosthetic delivery, just when the maturation healing phase peak occurs(6-7).
These continuous dis-reconnections may lead to soft tissue healing disruption with a long junctional epithelium till the IAJ.
Not to mention the fact that continuous disconnections create a link for the contamination of the connection and the exposure of soft tissues to abutment not always contaminated The only approach able to prevent this "physiological reaction" and allow a complete healing is to adopt a protocol aimed, after an intraoperative impression, to definitively screw the final abutment at the time of second surgery and allow soft tissue to heal undisturbed (so called "one-abutment/one-time) (8) Another factor affecting soft tissue/abutment interaction is the abutment macro design A recent systematic review our group recently produced, suggested that narrower abutments fail to show any difference in terms of soft tissue health (and this is reasonable) and esthetics (9).
On the other hand, the metanalysis highlighted significant differences in terms of MBL in favor of narrower abutments just because this configuration allows for more room for soft tissues supracrestal attachment, probably changing their fiber arrangement from parallel to the long axis to ring-shaped circular with a stronger connective seal Another factor related to the "abutment variable" that dramatically may affect soft tissue/abutment interaction, and therefore interacting with the underlaid bone, is its micro design.
In fact, the importance of the material should be shifted from the bulk to the external surface and its biochemophysical and topographic properties, including cleanliness.
In fact, decontamination of the abutment surface is a prerequisite for cell. Aim The present study will test the effect of different prosthetic modalities on conical and internal hex connection implants, assessing the radiographic MBL changes after one year.
Materials and Methods Study design The study was designed as a prospective, controlled clinical trial with a parallel design. Approval from the Ethics Committee will be obtained before the study commences. Selected patients were informed about the purpose of the study, and if they agreed to participate, they were recruited to participate in the clinical trial once they had signed the informed consent form.
Subject population Subjects in need of an implant-supported restoration will be screened for the following study criteria Consecutive patients fulfilling inclusion/exclusion criteria will enter the study. Once the implant is inserted, patients will be divided into three groups according to the time if their inclusion in the study.
Study groups (20 patients per group):
1. Group 1: Placing Lance Conical implant with a healing abutment. Three months later, after an impression, a screw-retained restoration will be seated using a Ti-Base abutment.
2. Group 2: Placing Lance+ (Internal Hex connection) implant with a healing abutment. Three months later, after an impression, a screw-retained restoration will be seated using a Ti-Base abutment.
3. Group 3: Placing Lance Conical implant together with Connect Abutment (tightened to 30 Ncm) with a Connect healing cap ("one time one abutment"). Screw retained restoration after 3 months.
Consecutive inclusion of patients - 1st- group 1, 2nd - group 2, 3rd - group 3 and vice versa.
Information to collect:
Inclusion day: Demographic data, medical condition Day of surgery: implant site, insertion torque, parallel X-ray. Suture removal - adverse effects. 3 months (impression) - parallel X-ray. Adverse effects. Loading day - parallel X-ray. Adverse effects. 6 months post-loading - parallel X-ray. Adverse effects. 12 months post-loading - parallel X-ray. Adverse effects, pocket depth, BOP.
Clinical photos and videos will be appreciated for future presentations.
Primary outcome variable: bone level changes 12 months post-loading Surgical and prosthetic protocol According to the manufacturer's instructions, using the Lance surgical kit, with tools for Conical connection and internal hex implants (fig 1 and 2).
Prosthetic parts will be inserted according to the manufacturer's instructions using the specific tools and a torque-controlled rachet.
Recruitment & Eligibility
- Status
- RECRUITING
- Sex
- All
- Target Recruitment
- 60
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Primary Outcome Measures
Name Time Method MBL one year post surgery magical bone level changes will be measured through X-rays
- Secondary Outcome Measures
Name Time Method peri-implant soft tissue variables one year post surgery PD
Trial Locations
- Locations (1)
Studi Odontoiatrici Luigi Canullo
🇮🇹Roma, RM, Italy
Studi Odontoiatrici Luigi Canullo🇮🇹Roma, RM, ItalyLuigi Canullo, ProfessorContact3476201976luigi.canullo@gmail.com