Comparison of Two Types of Videolaryngoscope and Direct Laryngoscope in Expected Non-difficult Airway Patients
- Conditions
- Laryngoscopes
- Interventions
- Device: The laryngoscope used for tracheal intubation under general anesthesia for patients with expected non-difficult airway conditions.
- Registration Number
- NCT04185675
- Lead Sponsor
- Sixth Affiliated Hospital, Sun Yat-sen University
- Brief Summary
Macintosh direct laryngoscope has been mostly widely used for anesthesiologists in operation rooms or emergency situations all over the world. With rapidly development of technical devices, nowadays videolaryngoscope has become more and more popular in hospitals, for it could improve first intubation success rate and it is easier for beginners to learn. And there are many different types of videolaryngoscope for different purpose, like with or without a channel, different curvature, and so go. In this study, our aim is to study whether the videolaryngoscope which can be adjustable or not costs less intubation time and causes fewer injury in expected non-difficult airway patients by experienced anesthesiologists, compared with the classic Macintosh direct laryngoscope.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 300
- age between18 and 65 years
- ASA(American Society of anesthesiologists) I-II
- BMI 18-30 kg/m2
- scheduled to receive elective surgery under general anesthesia with expected non-difficult airway in operation rooms.
- expected difficult airway
- allergy to anesthesia induction drugs
- scheduled to receive surgeries affecting vocalisation
- with high reflux aspiration risk
- with acute and chronic cardiac or respiratory failure
- with glucocorticoids medication history
- with mental disorder or transferred to SICU(Surgical Intensive Care Unit) or ICU after surgery who can not cooperate well with others
- refused or have participated in other clinical trials that may have effects on the outcomes of this study
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description nonadjustable videolaryngoscope The laryngoscope used for tracheal intubation under general anesthesia for patients with expected non-difficult airway conditions. - Macintosh laryngoscope The laryngoscope used for tracheal intubation under general anesthesia for patients with expected non-difficult airway conditions. - adjustable videolaryngoscope The laryngoscope used for tracheal intubation under general anesthesia for patients with expected non-difficult airway conditions. -
- Primary Outcome Measures
Name Time Method Tracheal intubation time time from the removal of the patient's face mask for preoxygenation to confirmation of good tube position based on continuous positive end-tidal carbon dioxide reading (at least three breaths without a significant visual decrease in capnography). total time to successful orotracheal intubation
- Secondary Outcome Measures
Name Time Method