Skip to main content
Clinical Trials/NCT02697825
NCT02697825UnknownNot Applicable

Correlation Between Intraocular Pressure and Optic Nerve Sheath Diameter

Rajiv Gandhi Cancer Institute & Research Center, India2 sites in 1 country100 target enrollmentStarted: September 1, 2015Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Sponsor
Enrollment
100
Locations
2
Primary Endpoint
correlation between rise of intraocular pressure and optic nerve sheath diameter

Study Overview

Brief Summary

This study involves observing and comparing Intraocular Pressure and Optic Nerve Sheath Diameter in steep trendelenburg position. Both observations will be done in same patient over the surgical duration.

Detailed Description

Steep trendelenburg position is required for various robotic surgical procedures like hysterectomy, radical prostatectomy etc. Both Intraocular Pressure and Optic Nerve Sheath Diameter are found to get increased while in this position.

Intraocular Pressure will be measured by schiotz tonometer over an hourly interval whereas Optic nerve sheath diameter will be measured with use of ultrasound using a probe of 7.5 Mega hertz. Both values will be measured in both the eyes and will be compared statistically to find any correlation which may exist between the two.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Diagnostic
Masking
None

Eligibility Criteria

Ages
40 Years to 65 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • robotic surgeries
  • surgical duration upto 4 hours
  • american society of anaesthesiologists 1 to 3

Exclusion Criteria

  • any history of opthalmic intervention
  • patient suffering from glaucoma
  • patients taking any diuretics for cardiac problems

Outcomes

Primary Outcomes

correlation between rise of intraocular pressure and optic nerve sheath diameter

Time Frame: 9 months

Intraocular pressure will be measured using schiotz tonometer whereas optic nerve sheath diameter will be assessed using ultrasound in same patient at same intervals. This will give us both the values of intraocular pressure and optic nerve sheath diameter at same time which as per previous studies increases and are statistically significant. After compilation of results it will be analyzed that whether both values increases in a correlated manner or not which will give us our results that whether increase of one value can tell the increase of other value.

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor
Rajiv Gandhi Cancer Institute & Research Center, India
Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Dr. Nitesh Goel

Doctor Nitesh Goel, Consultant Anaesthesia

Rajiv Gandhi Cancer Institute & Research Center, India

Study Sites (2)

Loading locations...

Similar Trials