Healing of Bone/Soft Tissue to Different Abutment Biomaterials and the Impact on Marginal Bone Loss

Not Applicable
Completed
Conditions
Bone Loss
Inflammation
Interventions
Device: dental implants
Device: Titanium Abutments
Device: cad-cam acrylic abutments
Device: Zirconia abutments
Procedure: Subcrestal
Device: platform-switch
Procedure: one-time one-abutment
Procedure: Torque 20 n/cm2
Registration Number
NCT01961635
Lead Sponsor
Implantology Institute
Brief Summary

In patients that require a dental implant, does zirconia compared to titanium, or cad-cam acrylic abutments, provide less inflammation, marginal bone loss or infection during the osseointegration period ?

Detailed Description

Place dental Implants and zirconia, titanium, acrylic or cad-cam acrylic abutments, torque to 20 n/cm2 Evaluate Changes in inflammatory levels from T0 (baseline) to T7-12 weeks (measure intermediate points at T0 (baseline),,T1-8 Weeks and T2-12 weeks) Also evaluate outcomes marginal bone loss, gingival height levels and osseointegration

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Single unit implant rehabilitation
  • Maxilla and mandible
  • Must accept treatment plan
  • Must sign informed consent
  • dental extraction performed at least 3 month prior
  • Must have at least 6 mm of residual bone
  • Absence of oral lesions
  • keratinized tissue must be present
Exclusion Criteria
  • If smoking and/or other drug addiction is present
  • If local anesthetic allergy is present
  • Patient subjected to chemical or radiotherapy
  • if Hepatic disease is present
  • If immunodepression is present
  • If Pregnancy is present
  • If Diabetes is present
  • If Heart disease is present

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Titanium AbutmentsTitanium AbutmentsPlace titanium one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Titanium Abutmentsplatform-switchPlace titanium one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Cad-Cam Acrylic abutmentscad-cam acrylic abutmentsPlace cad-cam acrylic one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Cad-Cam Acrylic abutmentsSubcrestalPlace cad-cam acrylic one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Zirconia AbutmentsZirconia abutmentsPlace zirconia one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Zirconia Abutmentsplatform-switchPlace zirconia one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Titanium AbutmentsTorque 20 n/cm2Place titanium one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Zirconia Abutmentsdental implantsPlace zirconia one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Titanium AbutmentsSubcrestalPlace titanium one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Cad-Cam Acrylic abutmentsdental implantsPlace cad-cam acrylic one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Zirconia AbutmentsSubcrestalPlace zirconia one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Zirconia Abutmentsone-time one-abutmentPlace zirconia one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Cad-Cam Acrylic abutmentsTorque 20 n/cm2Place cad-cam acrylic one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Zirconia AbutmentsTorque 20 n/cm2Place zirconia one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Titanium Abutmentsdental implantsPlace titanium one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Titanium Abutmentsone-time one-abutmentPlace titanium one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Cad-Cam Acrylic abutmentsplatform-switchPlace cad-cam acrylic one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Cad-Cam Acrylic abutmentsone-time one-abutmentPlace cad-cam acrylic one-time one-abutment in subcrestal platform-switch dental implants on the day of implant installation, torque 20 n/cm2
Primary Outcome Measures
NameTimeMethod
Gingival Inflammatory Changes from baseline to 12 weeksMeasure - T0 Implant installation T1- 1week post-surgery T2-two weeks T3-3weeks T4-4weeks T5-6weeks T6-8weeks T7-12 weeks

measure the amount of cytokines and interleukines (interleukin-8 (IL-8), macrophage inflammatory protein-1 (MIP-1 beta), interleukin-1 (IL-1 beta), interleukin-6 (IL-6), matrix metalloproteinase-8 (MMP-8) and matrix metalloproteinase-9 (MMP-9), metallopeptidase inhibitor 1 (TIMP-1), vascular endothelial growth factor (VEGF)), around different implant abutment materials, zirconia,titanium, acrylic, and cad-cam acrylic

Secondary Outcome Measures
NameTimeMethod
Gingival height12 weeks post-implant installation

measure with periodontal probe distance from implant platform to the most coronal point of gingival margin mesial, distal, buccal and lingual,in zirconia,titanium, acrylic, and cad-cam acrylic

Marginal Bone Lossmeasured at 12 weeks post-implant installation

Parallel periapical standardized radiographs to measure bone position in relation to implant platform, in zirconia,titanium, acrylic, and cad-cam acrylic

Osseointegration12 weeks post-implant installation

compare survival rate of dental implants rehabilitated with zirconia,titanium, acrylic, and cad-cam acrylic abutments

Height from gingiva to abutment12 weeks post implant installation

height from gingival margin to most coronal point of the abutment in zirconia, titanium, acrylic and acrylic cad-cam abutments

Trial Locations

Locations (1)

Faculdade de Medicina Dentária de Lisboa

🇵🇹

Lisbon, Portugal