MedPath

Safety and Effectiveness of PreserFlo and XEN Stents With or Without Amniotic Membrane in Glaucoma Surgery

Not Applicable
Not yet recruiting
Conditions
Glaucoma
Registration Number
NCT07143708
Lead Sponsor
Nova Scotia Health Authority
Brief Summary

Glaucoma is one of the leading causes of permanent blindness in the world. It happens when the optic nerve-the connection between the eye and the brain-is damaged. As this damage gets worse, vision is slowly lost.

Glaucoma treatments often begin with eye drops to lower eye pressure. If drops are not enough, surgery may be needed. The type of surgery depends on how advanced the glaucoma is and how much vision has already been lost.

Some glaucoma surgeries, including trabeculectomy, PreserFlo MicroShunt, and XEN Stent, create a new pathway for fluid to drain out of the eye. This helps lower pressure inside the eye.

However, after surgery, the body's natural healing process can sometimes cause inflammation and scarring, which may block the new drainage pathway. If this happens, eye pressure can rise again, and the surgery may not work as well as hoped.

This study is testing whether covering the PreserFlo or XEN devices with amniotic membrane (a safe tissue already used in other eye surgeries) can reduce scarring, improve healing, and lead to better long-term results. Amniotic membrane has already been used safely in many types of eye surgeries. It has been shown to improve healing and reduce scarring in some glaucoma surgeries. But it has not yet been studied in PreserFlo MicroShunt or XEN Stent procedures. The goal is to see if adding amniotic membrane makes the surgery safer and more effective for people with glaucoma.

Detailed Description

Glaucoma is the leading cause of permanent blindness worldwide. Glaucoma is damage to the optic nerve, which sends information from the eye to the brain. This damage causes vision to weaken. Treatment for glaucoma includes the use of medication drops and, ultimately, surgery. The type of surgery is decided by determining the severity and progress of an individual's vision loss.

Certain glaucoma surgeries (including PreserFlo microshunts, and Xen stents) involve creation of an alternative passage for the liquid inside of the eye to be drained. Glaucoma surgery is complex and excessive inflammation and scarring can increase pressure inside the eye and lead to surgical failure. We hope that covering PreserFlo microshunts and Xen stents with amniotic membrane will result in reduced scarring and better pressure outcomes after these surgeries.

Previous research has shown that amniotic membrane is safe for the eye and has improved the outcomes of other similar glaucoma surgeries. However, there are no studies that have investigated whether amniotic membrane is a safe and effective in PreserFlo microshunts, and Xen stents surgeries.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
156
Inclusion Criteria
  1. Age 18 years and older
  2. Patients selected for PreserFlo microshunt surgery and XEN stent alone or in combination with cataract surgery.
  3. Ability to comprehend the study procedures
Exclusion Criteria
  1. Unwilling or unable to give consent
  2. Unable to come for scheduled post-operative visits
  3. Pregnant or nursing women
  4. Previous cyclodestructive procedures, scleral buckling procedures, or presence of silicone oil
  5. Conjunctival scarring precluding a glaucoma surgery superiorly
  6. Active iris neovascularization or active proliferative retinopathy
  7. Vitreous in the anterior chamber for which a vitrectomy is anticipated.
  8. Previous trabeculectomy, tube-shunt implantation, or surgeries that shunt aqueous outflow into the subconjunctival space

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Primary Outcome Measures
NameTimeMethod
Rate of adverse eventsSurgery (Day 0) to 12 months

Proportion of study eyes with ≥1 of: persistent uveitis, blebitis, endophthalmitis, clinically significant hypotony, stent erosion, bleb dysesthesia, or loss of best-corrected visual acuity. Each AE recorded as yes/no; between-group comparisons via logistic regression (adjusting for device type and baseline IOP).

Relative Reduction in Intraocular Pressure (IOP) at 3, 6, and 12 MonthsBaseline to 3, 6, and 12 months

Percent change from baseline IOP at each post-operative visit. Calculated per study eye as:

\[(Baseline IOP - Visit IOP) / Baseline IOP\] × 100. Primary efficacy analysis uses a linear mixed-effects model (repeated measures) with fixed effects for treatment group (amniotic membrane vs no membrane), visit (3/6/12 months), treatment × visit interaction, device type (PreserFlo vs XEN), and baseline IOP; participant (study eye) included as a random effect. Estimates will report least-squares mean differences between groups in percent reduction at each visit and an overall treatment effect across visits, with 95% confidence intervals and p-values

Secondary Outcome Measures
NameTimeMethod
Number of re-operationsThrough 12 months post-op

To compare the number of re-operations per patient at 12 months between the treatment groups, we will use a negative binomial regression model. The dependent variable will be the total number of re-operations per patient, and the independent variable will be the treatment group. Results will be reported as incidence rate ratios (IRRs) with 95% confidence intervals and p-values.

Number of Glaucoma Medications3, 6 and 12 month post-op

Count of post-operative glaucoma medication classes required at each visit. Generalized linear mixed model with negative binomial distribution compares groups over time; reported as rate ratios with 95% CIs and p-values.

Time to Surgical FailureFrom surgery to 12 months post-op (failures assessed after postoperative Month 3)

Failure is defined as any of: (a) IOP \>21 mmHg or \<20% reduction from baseline on two consecutive visits; (b) IOP ≤5 mmHg on two consecutive visits (hypotony); (c) any re-operation for glaucoma; or (d) loss of light perception vision. Analyzed by Kaplan-Meier and Cox proportional hazards; reported as hazard ratio with 95% CI and p-value.

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.