MedPath

A Clinical Trial Evaluating the Effectiveness and Safety of the PowerMe Midline Catheter in the Chinese Population

Not Applicable
Completed
Conditions
Catheterization
Interventions
Device: catheter placement
Registration Number
NCT04719377
Lead Sponsor
Becton, Dickinson and Company
Brief Summary

This study is designed to evaluate the effectiveness and the safety of the PowerMeTM Midline Catheter in the Chinese population.

Detailed Description

This is a prospective, multi-center, open-label, randomized, controlled, non-inferiority clinical trial designed to evaluate the effectiveness and the safety of the PowerMeTM Midline Catheter compared to PIVC in the Chinese population in order to support the product's registration in China.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
256
Inclusion Criteria
  1. ≥18 years of age;
  2. Inpatient with a need for intravenous infusion for an expected period of more than 4 days but no more than 28 days;
  3. The veins in the upper limbs is suitable for puncture and catheterization of both the investigational device and the control device;
  4. Willing to provide written Informed Consent and complete the study per the protocol.
Read More
Exclusion Criteria
  1. Coagulation disorder or active bleeding;

  2. Skin injury, infection, or dermatosis at the site to be punctured;

  3. History of radiotherapy, thrombosis, or vascular surgery; arteriovenous fistula or phlebitis history at the area and/or vein to be catheterized;

  4. History of mental illness;

  5. End stage renal disease requires vein protection;

  6. Conditions with decreased venous flow in the extremity, such as lymphedema of the arm, etc.;

  7. Infusions of vesicant or irritant drugs, hyperosmotic infusate (the osmotic pressure >900mOsm/L in this study), parenteral nutrition, etc., which are not suitable for peripheral intravenous infusion (If other appropriate venous access is established for the aforementioned infusates, the patient may be enrolled).

  8. The evaluation of the upper limb veins is Grade II, the evaluation grade is as following:

    • 0 Veins are obviously bulged on the skin surface. The veins are touchable, thick, straight, soft, elastic and fixed.
    • I Veins are relatively full and faintly touchable. The veins are less elastic or slide easily.
    • II Veins are not full or collapsed and untouchable. The veins are hard or sliding. Phlebitis.
  9. Self-reported being pregnant or lactating;

  10. Other conditions that the investigator considers improper for the study;

  11. Participating in another study or already enrolled.

Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Powerme midline cathetercatheter placementPowerme midline catheter
peripheral intravenous cathetercatheter placementBD Pegusas peripheral intravenous catheter
Primary Outcome Measures
NameTimeMethod
Acceptance of the overall performance of the IV catheter systemup to 28 days

After the placement of the IV catheter system, the study nurse shall answer "yes/no" to the following questions:

1. Can the IV catheter system vent the air properly;

2. Can the IV catheter system be inserted and be placed in the blood vessel;

3. Can the needle tube be withdrawn from the septum;

After the removal of the IV catheter system, the study nurse shall answer "yes/no" to the following questions:

4. Can the IV catheter system be removed properly;

5. There is no leakage during the application of the IV catheter system (including the processes of venting, infusion, flushing and sealing, and indwelling).

Secondary Outcome Measures
NameTimeMethod
Success rate of the first insertion of the catheterFirst day, during catheter insertion

Successful first insertion means the IV catheter system can be successfully inserted into the blood vessel on the first insertion.

Indwelling timeup to 28 days

The retention time of the IV catheter system of each subject after successful insertion.

Rate of good performance of the pinch clampup to 28 days

If the pinch clamp can close and open the tubing properly, performance of the pinch clamp can be evaluated as "good".

Incidence of catheter blockageup to 28 days

The catheter system is blocked, causing the system to fail to infuse the fluid after it is connected to the infusion set/syringe.

Incidence of accidental dislodgementup to 28 days

Unintentional premature removal of the catheter from the vessel.

Incidence of phlebitisup to 28 days

Incidence of phlebitis

Incidence of adverse eventsup to 28 days

Incidence of adverse events

Incidence of serious adverse eventsup to 28 days

Incidence of serious adverse events

Trial Locations

Locations (4)

Hunan Cancer Hospital

🇨🇳

Changsha, China

Shanghai First General Hospital

🇨🇳

Shanghai, China

The First Affiliated Hospital of Soochow University

🇨🇳

Suzhou, China

Shanghai Ninth People's Hospital

🇨🇳

Shanghai, China

© Copyright 2025. All Rights Reserved by MedPath