跳至主要内容
临床试验/NCT07156812
NCT07156812已完成4 期

Custom-Made 3D PEEK Plates Versus 3D Titanium Plates in Mandibular Angle Fracture Fixation: A Randomized Controlled Clinical Trial

Alexandria University1 个研究点 分布在 1 个国家目标入组 18 人开始时间: 2022年2月1日最近更新:
适应症
干预措施

试验速览

阶段
4 期
状态
已完成
入组人数
18
试验地点
1
主要终点
Radiographic evaluation for the assessment of mean bone density at the fracture line [Time Frame: 12 weeks]

研究概览

简要总结

This investigation aimed to determine the clinical and radiographic efficacy of patient-specific, custom-made 3D PEEK plates in comparison with 3D titanium plates for the management of mandibular angle fractures.

详细描述

Eighteen patients with recent mandibular angle fractures indicated for open reduction and internal fixation were randomly allocated into two groups. The study group (n = 9) underwent fixation with custom-made 3D PEEK plates, while the control group (n = 9) received prebent 3D titanium plates adapted on virtually reduced models. Follow-up extended to 12 weeks. Clinical parameters included operative time, postoperative occlusion, interfragmentary stability, wound healing, and bite force recovery. Radiographic evaluation was conducted using computed tomography scans acquired immediately postoperatively and at 12 weeks, assessing fracture healing and mean bone density.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Investigator)

盲法说明

Patients were allocated in a 1:1 ratio using an on-site computer software system with concealed allocation through sequentially numbered, opaque, sealed envelopes (SNOSE). Group A was treated with custom made 3D PEEK plates and Group B with 3D titanium plates.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •patients with recent mandibular angle fracture adults without gender predilection who agreed to follow-up, fractures requiring open reduction and internal fixation, medically fit for general anesthesia

排除标准

  • •medically compromised patients, fractures with infection, pathological or old fractures, completely edentulous patients, comminuted fractures

研究组 & 干预措施

patients with recent mandibular angle fractures managed with custome made 3D PEEK plate

Experimental

custome made 3D PEEK plate

干预措施: Custome made 3D PEEK plate (Device)

patients with recent mandibular angle fractures managed with 3D Titanium plates

Experimental

3D Titanium plates

干预措施: 3D Titanium plate (Device)

结局指标

主要结局

Radiographic evaluation for the assessment of mean bone density at the fracture line [Time Frame: 12 weeks]

时间窗: 12 weeks

Mean bone density at the fracture line was assessed using Computed Tomography (CT) scan in Hounsfield Units (HU)

Bite force recovery.

时间窗: 12 weeks

bite force recovery measured by a Piezoresistive force transduce sensor: FlexiForce A201 sensor (FlexiForce sensor, by Tekscan Boston, MA, USA. www.tekscan.com)

次要结局

  • Clinical evaluation for interfragmentary stability.(12 weeks)
  • clinical evaluation of wound healing(14 days)
  • Clinical evaluation of postoperative occlusion(12 week)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验