MedPath

Coupling Between Clotting Characteristics in Chronic Hemodialysis Patients and the Hemodialyzer Patency

Not Applicable
Completed
Conditions
Coagulation
Bleeding
Interventions
Other: Amount of anticoagulant Clexane
Registration Number
NCT05440201
Lead Sponsor
University Hospital, Ghent
Brief Summary

Twenty stable chronic hemodialysis patients are included and will undergo one, two, three or four midweek test dialysis sessions, depending on a flow chart to follow.

All patients are started (week 1) with an anticoagulant Clexane 50IE/kg and are dialyzed with their regular dialyzer and dialysis machine. Depending on the results of measured clotting characteristics and of the dialyzer scanning (i.e. percentage open fibers), it is decided (via the flow chart) whether the patient gets a second session (and so on) with an adapted anticoagulation therapy to ameliorate fiber patency while limiting bleedings.

Detailed Description

Twenty stable chronic hemodialysis (HD) patients with a well functioning vascular access will be included. Patients have a hematocrit higher than 30%, and have no known heparin allergy, no severe thrombocytopenia (platelets more than 50.000/µL) or active infection. Patients are not treated with vitamin K antagonists.

The study is limited to maximum four test sessions at midweek per patient. Patients are dialysed with their regular dialyzer on their regular dialysis machine. Patients will get a dialysis of 240min with blood flow 300mL/min and dialysate flow 500mL/min. Ultrafiltration is set according to the patient's needs. As usual, patients will get an administration of an anticoagulant in the dialysis circuit to avoid clotting of the extracorporeal circuit.

At the start of the first test session, patients receive the anticoagulant Clexane 20-30IE/kg (0.2-0.3mg/kg - rounded to 10).

In these 20 patients, clotting characteristics are measured by performing clotting tests, such as thrombin generation test, thrombo-elastogram with Rotem, Platelet Function Analysis (PFA), flow chamber, and the measurement of biochemical markers such as anti-thrombin-III (AT-III), p-selectin, and antiXa. For these measurements, blood is sampled predialysis, 30min after dialysis start, and post dialysis.

In order to link these clotting characteristics with dialyzer patency, the dialyzer will be scanned post dialysis with a gold standard micro Computed Tomography (CT) technique. At the end of the dialysis session, a standard rinsing procedure is applied. The dialyzer is then dried for 12-24 hours by continuous positive pressure ventilation in blood and dialysate compartment. During scanning, the dialyzer is mounted vertically on a rotating disc in front of the X-rays source. After image reconstruction, we get images of cross sections of the dialyzer. The non-blocked fibers are counted with an open source computer program used for biological image analysis. By comparing the number of non-blocked fibers with the total number of fibers in a non-used dialyzer, the percentage of fiber blocking can be derived.

By comparing the percentage of fiber blocking with the clotting characteristics in the patient, insight can be obtained in the value of the different clotting characteristics.

Based on the results of the first midweek session, it is decided (based on a flow chart) whether the patient will also get a second, third and eventual fourth dialysis test session at midweek with an adapted anticoagulation therapy to ameliorate fiber patency while limiting bleedings.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
20
Inclusion Criteria
  • chronic hemodialysis patients
  • well functioning vascular access
  • hematocrit higher than 30%
Exclusion Criteria
  • known heparin allergy
  • severe thrombocytopenia (platelets more than 50.000/µL)
  • active infection
  • treatment with vitamin K antagonists

Study & Design

Study Type
INTERVENTIONAL
Study Design
SEQUENTIAL
Arm && Interventions
GroupInterventionDescription
Second test sessionAmount of anticoagulant ClexaneThe dosis of Clexane is lowered or increased by 50%, depending on the results of the fiber patency and clotting characteristics of the previous session.
Third test sessionAmount of anticoagulant ClexaneThe dosis of Clexane is lowered or increased by 50%, depending on the results of the fiber patency and clotting characteristics of the previous session.
First test sessionAmount of anticoagulant ClexaneFor each patient, the anticoagulant Clexane 50IE/kg is administered in the venous line of the dialysis circuit once blood is detected by the dialysis machine.
Fourth test sessionAmount of anticoagulant ClexaneThe dosis of Clexane is lowered or increased by 50%, depending on the results of the fiber patency and clotting characteristics of the previous session.
Primary Outcome Measures
NameTimeMethod
Dialyzer fiber patency4 midweek sessions

Percentage of open fibers in de dialyzer post dialysis

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Ghent University Hospital

🇧🇪

Gent, Belgium

© Copyright 2025. All Rights Reserved by MedPath