简要总结

While an upper limit of 26°C has been shown to be protective for heat-vulnerable older occupants (DOI: 10.1289/EHP11651), this recommendation did not consider the added heat burden associated with increases in internal heat production accompanying activities of daily living or the restriction to heat loss caused by clothing insulation. To safeguard the health of older adults, health agencies worldwide recommend the remain in cool space indoors, avoid strenuous activity, wear lightweight clothing, and drink cool water regularly throughout the day. However, older adults do not sense heat as well as their younger counterparts. Consequently, they may not take appropriate countermeasures to mitigate physiological strain from indoor overheating. This may include overdressing despite high indoor temperatures. In other cases, individuals may wear insulated clothing in hot weather to observe cultural or religious modesty requirements, which serve as expressions of faith and identity rather than a tool for thermoregulation. Further, individuals may be unaware of the consequences of increases in physical activity on heat gain and may therefore not adjust their normal day-to-day activity levels to prevent potentially dangerous rises in body temperature. Consequently, this may necessitate a lowering of recommended upper indoor temperature limit during hot weather.

To address these important considerations, on separate occasions the investigators will assess the change in body temperature and cardiovascular strain in older adults (65-85 years) exposed for 8 hours to the recommended indoor temperature upper limit of 26°C and 45% relative humidity equivalent humidex of 29 (considered comfortable) while they A) perform seated rest dressed in light clothing (t-shirt, shorts and socks), B) perform light exercise (stepping exercise to simulate activities of daily living, 4-4.5 METS) every hour (except during lunch hour period) dressed in light clothing, C) perform light exercise (4-4.5 METS) every hour (except during lunch hour period) dressed in light clothing (t-shirt, shorts and socks) and an added clothing layer (sweatshirt and sweatpants) and D) perform seated rest dressed in light clothing (t-shirt, shorts and socks) and an added clothing layer (sweatshirt and sweatpants). With this experimental design, investigators will assess the effects of added clothing insulation and light activity, representative in activities of daily living on physiological strain and identify whether refinements in the recommended 26°C indoor temperature limit may be required.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Basic Science
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
65 Years 至 85 Years(Older Adult)
性别
All
接受健康志愿者
是

入选标准

  • •Non-smoking.
  • •English or French speaking.
  • •Ability to provide informed consent.
  • •with or without a) chronic hypertension (elevated resting blood pressure; as defined by Heart and Stroke Canada and Hypertension Canada), b) type 2 diabetes as defined by Diabetes Canada, with at least 5 years having elapsed since time of diagnosis

排除标准

  • •Episode(s) of severe hypoglycemia (requiring the assistance of another person) within the previous year, or inability to sense hypoglycemia (hypoglycemia unawareness).
  • •Serious complications related to your diabetes (gastroparesis, renal disease, uncontrolled hypertension, severe autonomic neuropathy).
  • •Uncontrolled hypertension - BP >150 mmHg systolic or >95 mmHg diastolic in a sitting position.
  • •Restrictions in physical activity due to disease (e.g. intermittent claudication, renal impairment, active proliferative retinopathy, unstable cardiac or pulmonary disease, disabling stroke, severe arthritis, etc.).
  • •Use of or changes in medication judged by the patient or investigators to make participation in this study inadvisable.
  • •Cardiac abnormalities identified during screening

研究组 & 干预措施

Exposure to indoor temperature upper limit without physical activity and added clothing.

Experimental

Participants, dressed in light clothing (t-shirt, shorts and socks), perform seated rest while exposed daylong (8 hours) to an indoor temperature maintained at 26°C and 45% relative humidity (humidex equivalent of 29).

干预措施: Simulated indoor temperature upper limit (Other)

Exposure to indoor temperature upper limit with physical activity.

Experimental

Participants, dressed in light clothing (t-shirt, shorts and socks), perform light exercise (i.e., stepping, representing activities of daily living, 4-4.5 METS) every hour (except during lunch hour period) while exposed daylong (8 hours) to an indoor temperature maintained at 26°C and 45% relative humidity (humidex equivalent of 29).

干预措施: Simulated indoor temperature upper limit (Other)

Exposure to indoor temperature upper limit with added clothing.

Experimental

Participants, dressed in light clothing (t-shirt, shorts and socks) and an added clothing layer (sweatshirt and sweatpants), perform seated rest while exposed daylong (8 hours) to an indoor temperature maintained at 26°C and 45% relative humidity (humidex equivalent of 29).

干预措施: Simulated indoor temperature upper limit (Other)

Exposure to indoor temperature upper limit with physical activity and added clothing.

Experimental

Participants, dressed in light clothing (t-shirt, shorts and socks) and an added clothing layer (sweat shirt and sweat pants), perform light exercise (i.e., stepping, representing activities of daily living, 4-4.5 METS) every hour (except during lunch hour period) while exposed daylong (8 hours) to an indoor temperature maintained at 26°C and 45% relative humidity (humidex equivalent of 29).

干预措施: Simulated indoor temperature upper limit (Other)

结局指标

主要结局

Hydration status during daylong exposure to indoor overheating

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Hydration status measured via assessing the urine specific gravity of a urine sample.

Activity levels during daylong exposure to indoor overheating

时间窗: End of 8 hour daylong exposure

Activity levels assessed via a wearable monitor (Actical) containing an accelerometer worn on the wrist and hip.

Core temperature (Peak) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Peak rectal temperature (15 min average) during exposure. Rectal temperature is measured continuously throughout the 8 hour exposure to the simulated indoor temperature upper limit.

Core temperature (AUC) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Areas under the curve (AUC) of rectal temperature during the 8 hour exposure to the simulate indoor temperature upper limit.

Core temperature end of daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Rectal temperature measured at hour 8 of exposure to indoor temperature limit (15-min average).

Mean skin temperature (Peak) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Peak mean skin temperature (15 min average) during exposure. Mean skin temperature as calculated from skin temperature measured across 7 body regions is measured continuously throughout the 8 hour exposure to the simulated indoor temperature upper limit.

Mean skin temperature (AUC) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Areas under the curve (AUC) of mean skin temperature as calculated over 7 body regions during the 8 hour exposure to the simulate indoor temperature upper limit.

Mean skin temperature end of daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Mean skin temperature measured over 7 body regions at hour 8 of exposure to indoor temperature limit (15-min average).

Heat rate (Peak) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Peak heart rate (15 min average) during exposure. Heart rate is measured continuously throughout the 8 hour exposure to the simulated indoor temperature upper limit.

Heart rate (AUC) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Areas under the curve (AUC) of heart rate during the 8 hour exposure to the simulate indoor temperature upper limit.

Heart rate end of daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Heart rate measured at hour 8 of exposure to indoor temperature limit (15-min average).

Heart rate variability: RMSSD during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Root mean squared standard deviation of normal-to-normal R-wave to R-wave intervals (RMSSD) measured during 5 minutes of paced breathing (15 breaths/min) with participants in the supine position. RMSSD will be evaluated twice, during two paced breathing periods (separated by 4 min of supine rest).

Heart rate variability: SDNN during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Standard deviation of normal-to-normal R-wave to R-wave intervals (SDNN) measured during 5 minutes of paced breathing (15 breaths/min) with participants in the supine position. SDNN will be evaluated twice, during two paced breathing periods (separated by 4 min of supine rest).

Cardiac response to standing from supine (30:15 ratio) during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Cardiac response to standing evaluated as the ratio between the highest R-wave to R-wave interval (lowest heart rate) measured at the 30th heart beat after standing from supine (+/- 5 beats) and the lowest R-wave to R-wave interval (highest heart rate) measured at the 15th heart beat after standing (+/- 5 beats). Cardiac response to standing will be evaluated twice, during two lying-to-standing tests (separated by 10 min of supine rest).

Systolic response to standing from supine during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Systolic blood pressure response to standing evaluated as the difference in blood pressure measured between the standing and supine. Standing systolic blood pressure will be taken as the lowest value of those measured after 60 and 120 seconds of standing. Systolic response to standing will be evaluated twice, during two lying-to-standing tests (separated by 10 min of supine rest).

Systolic blood pressure during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Systolic blood pressure measured in triplicate via automated oscillometry (\~60 seconds between measures).

Diastolic blood pressure during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Diastolic blood pressure measured in triplicate via automated oscillometry (\~60 seconds between measures).

Rate pressure product during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Rate pressure product, an index of myocardial work and strain, calculated as systolic blood pressure x heart rate.

Reaction time during daylong exposure to indoor temperature limit (cognitive function).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Participants will be provided with a tablet device with the Sway Medical testing platform for the assessment of reaction time. Participants will be asked to initiate a movement of the device in response to a visual cue.

Impulse control during daylong exposure to indoor temperature limit (cognitive function).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Participants will be provided with a tablet device with the Sway Medical testing platform for the assessment of impulse control. Participants will be asked to respond to both "go" and "no-go" visual cues. In response to the "go" cue, participants will initiate a movement of the device.

CDC 4-Stage Balance Test during daylong exposure to indoor temperature limit (postural stability).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

To assess postural stability, participants hold a tablet to their chest, then auditory cues guide participants through four consecutive stances, feet side by side, instep of one foot touching the big toe of the other foot, tandem stand with one foot in front of the other, heel touching toe, and stand on one foot. The balance assessment will be evaluated based on movement detected by an accelerometer integrated into the hardware of the tablet device (Sway Medical Inc).

BTrackS Balance Assessment during daylong exposure to indoor temperature limit (postural stability).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

To assess postural stability, participants will be asked to stand on a BTracks force plate with their feet spread out to shoulder width while looking straight ahead. The assessment will comprise of one trial lasting 120 seconds in length. Center of pressure (COP) vector data along vertical (y) and horizontal (x) axes will be summed for the total path excursion length (cm) during each trial.

Fluid consumption during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure

Average hourly fluid consumption calculated by weighing participant water intake at the start and end of each hour of exposure (normalized to the exposure duration).

Fluid loss during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure

Fluid loss calculated as the change in body mass during each exposure presented as a percentage of baseline body mass (corrected for food consumption).

Change in plasma volume during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure.

Change in plasma volume from baseline values calculated from duplicate measurements of hemoglobin and hematocrit at the start and end of each exposure using the technique by Dill and Costill.

Thermal comfort scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thermal comfort assessed via a visual analog scale ("How comfortable does your body temperature feel?") ranging from "very uncomfortable" to "comfortable".

Thirst sensation scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thirst sensation assessed via a visual analog scale ranging from "very, very thirsty" to "not thirsty at all".

Arousal scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Felt arousal scale assessed via a visual analog scale ("How worked up are you?") ranging from "high arousal" to "low arousal".

Thermal sensation scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thermal sensation assessed via a visual analog scale ("How hot do you feel?") ranging from "extremely hot" to "neutral"(midpoint: hot)

Thermal sensation 2 scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thermal sensation assessed via a visual analog scale ("How do you feel?") ranging from "hot" to "cold"(midpoint: neutral)

Orthostatic intolerance symptoms assessment during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure.

Cumulative sum of scores on 6 questions asking participant to rank symptoms associated with orthostatic intolerance during the lying to standing tests. All symptoms scored on a scale from 0 (none) to 10 (worst possible) and include feelings of: (1) "dizziness, lightheadedness, feeling faint, or feeling like you might black out"; (2) "Problems with vision (blurring, seeing spots, tunnel vision, etc.)"; (3) "Weakness"; (4) "Fatigue"; (5) "Trouble concentrating"; and (6) "Head and neck discomfort".

Feel good scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Feel good assessed via a visual analog scale ("How good do you feel?") ranging from "very good" to "very bad"(midpoint: neutral)

Perceived exertion scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Perceived exertional assessed via a visual analog scale ("How hard are you working?") ranging from "no exertional at all" to "maximal exertion"

Core temperature (Peak) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Peak rectal temperature (15 min average) during exposure. Rectal temperature is measured continuously throughout the 8 hour exposure to the simulated indoor temperature upper limit.

Core temperature (AUC) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Areas under the curve (AUC) of rectal temperature during the 8 hour exposure to the simulate indoor temperature upper limit.

Core temperature end of daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Rectal temperature measured at hour 8 of exposure to indoor temperature limit (15-min average).

Mean skin temperature (Peak) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Peak mean skin temperature (15 min average) during exposure. Mean skin temperature as calculated from skin temperature measured across 7 body regions is measured continuously throughout the 8 hour exposure to the simulated indoor temperature upper limit.

Mean skin temperature (AUC) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Areas under the curve (AUC) of mean skin temperature as calculated over 7 body regions during the 8 hour exposure to the simulate indoor temperature upper limit.

Mean skin temperature end of daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Mean skin temperature measured over 7 body regions at hour 8 of exposure to indoor temperature limit (15-min average).

Heat rate (Peak) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Peak heart rate (15 min average) during exposure. Heart rate is measured continuously throughout the 8 hour exposure to the simulated indoor temperature upper limit.

Heart rate (AUC) during daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Areas under the curve (AUC) of heart rate during the 8 hour exposure to the simulate indoor temperature upper limit.

Heart rate end of daylong exposure to indoor temperature limit.

时间窗: End of 8 hour daylong exposure

Heart rate measured at hour 8 of exposure to indoor temperature limit (15-min average).

Heart rate variability: RMSSD during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Root mean squared standard deviation of normal-to-normal R-wave to R-wave intervals (RMSSD) measured during 5 minutes of paced breathing (15 breaths/min) with participants in the supine position. RMSSD will be evaluated twice, during two paced breathing periods (separated by 4 min of supine rest).

Heart rate variability: SDNN during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Standard deviation of normal-to-normal R-wave to R-wave intervals (SDNN) measured during 5 minutes of paced breathing (15 breaths/min) with participants in the supine position. SDNN will be evaluated twice, during two paced breathing periods (separated by 4 min of supine rest).

Thermal sensation 2 scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thermal sensation assessed via a visual analog scale ("How do you feel?") ranging from "hot" to "cold"(midpoint: neutral)

Cardiac response to standing from supine (30:15 ratio) during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Cardiac response to standing evaluated as the ratio between the highest R-wave to R-wave interval (lowest heart rate) measured at the 30th heart beat after standing from supine (+/- 5 beats) and the lowest R-wave to R-wave interval (highest heart rate) measured at the 15th heart beat after standing (+/- 5 beats). Cardiac response to standing will be evaluated twice, during two lying-to-standing tests (separated by 10 min of supine rest).

Systolic response to standing from supine during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Systolic blood pressure response to standing evaluated as the difference in blood pressure measured between the standing and supine. Standing systolic blood pressure will be taken as the lowest value of those measured after 60 and 120 seconds of standing. Systolic response to standing will be evaluated twice, during two lying-to-standing tests (separated by 10 min of supine rest).

Systolic blood pressure during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Systolic blood pressure measured in triplicate via automated oscillometry (\~60 seconds between measures).

Diastolic blood pressure during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Diastolic blood pressure measured in triplicate via automated oscillometry (\~60 seconds between measures).

Rate pressure product during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Rate pressure product, an index of myocardial work and strain, calculated as systolic blood pressure x heart rate.

Reaction time during daylong exposure to indoor temperature limit (cognitive function).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Participants will be provided with a tablet device with the Sway Medical testing platform for the assessment of reaction time. Participants will be asked to initiate a movement of the device in response to a visual cue.

Impulse control during daylong exposure to indoor temperature limit (cognitive function).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Participants will be provided with a tablet device with the Sway Medical testing platform for the assessment of impulse control. Participants will be asked to respond to both "go" and "no-go" visual cues. In response to the "go" cue, participants will initiate a movement of the device.

CDC 4-Stage Balance Test during daylong exposure to indoor temperature limit (postural stability).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

To assess postural stability, participants hold a tablet to their chest, then auditory cues guide participants through four consecutive stances, feet side by side, instep of one foot touching the big toe of the other foot, tandem stand with one foot in front of the other, heel touching toe, and stand on one foot. The balance assessment will be evaluated based on movement detected by an accelerometer integrated into the hardware of the tablet device (Sway Medical Inc).

BTrackS Balance Assessment during daylong exposure to indoor temperature limit (postural stability).

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

To assess postural stability, participants will be asked to stand on a BTracks force plate with their feet spread out to shoulder width while looking straight ahead. The assessment will comprise of one trial lasting 120 seconds in length. Center of pressure (COP) vector data along vertical (y) and horizontal (x) axes will be summed for the total path excursion length (cm) during each trial.

Fluid consumption during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure

Average hourly fluid consumption calculated by weighing participant water intake at the start and end of each hour of exposure (normalized to the exposure duration).

Fluid loss during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure

Fluid loss calculated as the change in body mass during each exposure presented as a percentage of baseline body mass (corrected for food consumption).

Change in plasma volume during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure.

Change in plasma volume from baseline values calculated from duplicate measurements of hemoglobin and hematocrit at the start and end of each exposure using the technique by Dill and Costill.

Thermal comfort scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thermal comfort assessed via a visual analog scale ("How comfortable does your body temperature feel?") ranging from "very uncomfortable" to "comfortable".

Thirst sensation scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thirst sensation assessed via a visual analog scale ranging from "very, very thirsty" to "not thirsty at all".

Arousal scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Felt arousal scale assessed via a visual analog scale ("How worked up are you?") ranging from "high arousal" to "low arousal".

Thermal sensation scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Thermal sensation assessed via a visual analog scale ("How hot do you feel?") ranging from "extremely hot" to "neutral"(midpoint: hot)

Orthostatic intolerance symptoms assessment during daylong exposure to indoor temperature limit.

时间窗: At end of 8 hour daylong exposure.

Cumulative sum of scores on 6 questions asking participant to rank symptoms associated with orthostatic intolerance during the lying to standing tests. All symptoms scored on a scale from 0 (none) to 10 (worst possible) and include feelings of: (1) "dizziness, lightheadedness, feeling faint, or feeling like you might black out"; (2) "Problems with vision (blurring, seeing spots, tunnel vision, etc.)"; (3) "Weakness"; (4) "Fatigue"; (5) "Trouble concentrating"; and (6) "Head and neck discomfort".

Feel good scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Feel good assessed via a visual analog scale ("How good do you feel?") ranging from "very good" to "very bad"(midpoint: neutral)

Perceived exertion scale during daylong exposure to indoor temperature limit.

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Perceived exertional assessed via a visual analog scale ("How hard are you working?") ranging from "no exertional at all" to "maximal exertion"

Hydration status during daylong exposure to indoor overheating

时间窗: At the start (hour 0) and end of 8 hour daylong exposure

Hydration status measured via assessing the urine specific gravity of a urine sample.

Activity levels during daylong exposure to indoor overheating

时间窗: End of 8 hour daylong exposure

Activity levels assessed via a wearable monitor (Actical) containing an accelerometer worn on the wrist and hip.

次要结局

  • Profiles of Mood States (POMS) during daylong exposure to indoor temperature limit.(At the start (hour 0) and end of 8 hour daylong exposure)
  • Environmental Symptoms Questionnaire (ESQ) during daylong exposure to indoor temperature limit.(At the start (hour 0) and end of 8 hour daylong exposure)
  • Sleep quality and quantify assessment during daylong exposure to indoor temperature limit.(At start of 8 hour daylong exposure.)
  • Profiles of Mood States (POMS) during daylong exposure to indoor temperature limit.(At the start (hour 0) and end of 8 hour daylong exposure)
  • Environmental Symptoms Questionnaire (ESQ) during daylong exposure to indoor temperature limit.(At the start (hour 0) and end of 8 hour daylong exposure)
  • Sleep quality and quantify assessment during daylong exposure to indoor temperature limit.(At start of 8 hour daylong exposure.)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Glen P. Kenny

Full Professor, University Research Chair

University of Ottawa

研究点 (2)

Loading locations...

相似试验