MedPath

Motorized Fine Needle Biopsy vs Standard Needles

Not Applicable
Recruiting
Conditions
Liver Diseases
Pancreas Disease
Registration Number
NCT06298604
Lead Sponsor
Instituto Ecuatoriano de Enfermedades Digestivas
Brief Summary

Recent improvements in punctures techniques and needles now allow for the collection of high-quality specimens comparable to core needle biopsy. A newly developed motorized fine needle biopsy (mFNB), the Precision-GI (Limaca, Israel) promises intact tissue acquisition without sample damage, relying on controlled axial tissue cutting and high-speed rotational coring for optimized tissue acquisition.

Given the advancement mentioned, the investigators aim to compare the performance of the mFNB with the standard needle during the acquisition of endoscopic ultrasound (EUS)-guided pancreatic and liver specimens through a prospective, interventional, single-center trial. The study will consist of two groups of patients: one assigned to the standard fine needle biopsy (FNB) and the other to the mFNB. The primary study outcomes will include sample quality (core integrity), and diagnostic accuracy.

Detailed Description

The development of Endoscopic ultrasound-guided tissue acquisition (EUS-TA) has been remarkable. Initially focused on obtaining samples from the pancreas, it has expanded significantly to include various organs adjacent to the gastrointestinal system (i.e., liver, lymph nodes, adrenal glands).

One of the key advancements in EUS-TA involves the shift from cytological analysis, with fine-needle aspiration (FNA), to histological and even genetic evaluations, with fine-needle biopsies (FNB). FNB addresses some limitations associated with FNA, such as low tumor cellularity and the inability to retain cellular architecture.

Recent improvements in puncture techniques and needles, allow for the collection of high-quality specimens, comparable to core needle biopsy, to achieve standards for specimen adequacy (i.e., intact liver cores of at least 15-20 mm with a complete portal triad count of 11). Some current available needle designs include the crown type, flanged type, 20 Gauge FNB needles with forward-faced core traps, and the fork-tip needles, demonstrating high diagnostic accuracy and a low rate of adverse events.

The Precision-GI is a new motorized fine needle (mFNB) developed by LIMACA Medical in Israel for EUS-guided FNB. It operates using a battery-powered motor that enables controlled axial tissue cutting and high-speed rotational coring for optimized tissue acquisition. Moreover, a sharp stylet facilitates crossing through the gastrointestinal wall, allowing for the reach of target lesions. The rotational electromechanical cutting movement into the lesion promises intact motorized tissue acquisition without sample damage.

In the present study, the investigators aim to compare the performance of the mFNB with the standard needle during the acquisition of EUS-guided pancreatic and liver specimens. The study will consist of two groups of patients: one assigned to the standard fine needle biopsy (FNB) and the other to the mFNB. The primary study outcomes will include sample quality (core integrity), and diagnostic accuracy.

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Patients between 18 and 99 years
  • Patients referred to our center who require EUS-guided liver or pancreas biopsy.
  • Male or female patients.
  • Patients able to give consent
Exclusion Criteria
  • Pregnancy or nursing
  • Patients with coagulation disorders (platelets <50.000/mm3, international normalised ratio (INR) >2)
  • Any underlying medical condition that contraindicates EUS-guided fine needle biopsy such as anatomical alterations, significant gastric outlet obstruction, collateral intervening vessels.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Primary Outcome Measures
NameTimeMethod
Diagnostic accuracy according to histological analysisUp to one week

Proportion of subjects with a definitive diagnosis based on the number of passes and throws for tissue acquisition.

Endoscopic ultrasound fine needle biopsy sample qualityUp to two hours after the procedures

Based on tissue "core"; Tissue core is defined as a architecturally intact piece of at least 550 micron in the greatest axis. The tissue core will be evaluated in both groups by the pathologist immediately after its acquisition.

Secondary Outcome Measures
NameTimeMethod
Tissue blood contaminationUp to one hour

Evaluation of tissue blood contamination will be based on a sample quality score:

1. Only blood

2. High (\>50% of the surface of the slide)

3. Moderate (25%-50% of the surface of the slide)

4. Low (\<25% of the surface of the slide)

Trial Locations

Locations (1)

Instituto Ecuatoriano de Enfermedades Digestivas (IECED)

🇪🇨

Guayaquil, Ecuador

Instituto Ecuatoriano de Enfermedades Digestivas (IECED)
🇪🇨Guayaquil, Ecuador
Carlos Robles-Medranda, MD FASGE
Principal Investigator
Raquel Del Valle, MD
Sub Investigator
Maria Egas-Izquierdo, MD
Sub Investigator
Jorge Baquerizo-Burgos, MD
Sub Investigator
Domenica Cunto, MD
Sub Investigator
Juan Alcivar-Vasquez, MD
Sub Investigator
Daniela Tabacelia, MD
Sub Investigator
Martha Arevalo-Mora, MD
Sub Investigator
Miguel Puga-Tejada, MD
Sub Investigator
Gustavo Rubio, MD
Sub Investigator
Hannah Pitanga-Lukashok, MD
Sub Investigator

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.