Vital Signs Data Collection Using "Comestai" Application

Buzzi Children's Hospital1 site in 1 country3,000 target enrollmentJune 1, 2024
ConditionsVital Signs

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Vital Signs
Sponsor
Buzzi Children's Hospital
Enrollment
3000
Locations
1
Primary Endpoint
Data Collection Storage and Processing-Pulse rate
Status
Recruiting
Last Updated
5 months ago

Overview

Brief Summary

The purpose of the study is to verify and validate the parameters collected from mobile devices via the app named "Comestai" and from reference devices. The assessments considered to define comorbidities are included.. Specifically, collection of vital parameters (Blood Pressure, Heart Rate, Respiratory Rate, Oxygen Saturation) through the "Comestai" Application via mobile phones (using photoplethysmographic method) and reference devices such as Withings-Blood Pressure Monitor Connect® (for Blood Pressure), Polar Verity Sense® (for Heart Rate), Masimo-finger sensor® (for Oxygen Saturation, Respiratory Rate), comparing and confirming them. Consent will be sought for the viewing and collection of blood test results that are normally included in evaluations for subjects with overweight and/or obesity and/or diabetes.

Estimated time required for each measurement recording: 10-15 minutes per subject

Total number of subjects: 3000

Detailed Description

Early detection of variations in vital parameters allows for the identification of changes in patients' health status and the provision of recommendations for therapeutic adjustments. The application named "Comestai" is a non-invasive and easy-to-use tool that enables the measurement of vital parameters. The app allows users to simultaneously measure vital parameters such as Heart Rate (HR), Respiratory Rate (RR), Oxygen Saturation (SpO2), and Blood Pressure (BP) using the photoplethysmographic method with the front camera of a mobile device. The use of simultaneous vital parameter measurement systems like apps can enhance self-monitoring of health status and improve patient care. In this study, vital parameters will be measured using the "Comestai" application and compared and validated with measurements from standard clinical practice devices. Consent will be sought for the viewing and collection of biochemical evaluation results typically required for individuals with overweight and/or obesity and/or diabetes. "Comestai" Application: This wellness app allows for non-invasive measurement of vital parameters, enabling users to detect SpO2, HR, RR, and BP by looking at the front camera of a mobile device ("By Face"). The measurement method used is Remote Photoplethysmography (rPPG). This is a prospective, open-label, study to collect vital parameters using the Comestai application by looking at the front camera of a mobile device ("By Face"). The measurement method of the app is Remote Photoplethysmography (rPPG). The study plans to enroll up to 3000 subjects Each subject will be assigned a specific identification number (Subject ID). During the evaluation, the following data will be recorded in the Electronic Case Report Form (eCRF): Medical history of the subject Current or past therapies Demographic data (date of birth, sex) Smoking habits Physical characteristics (height in meters, weight in kilograms, Body Mass Index in kg/m\^2, and phototype) During the 'By Face' measurement of vital parameters with the app, subjects will be asked to sit in a comfortable place, looking at the phone screen (about 25 cm away) with their face fully uncovered (no masks, hats, or any facial accessories). During data collection, the subject should remain still and breathe steadily. The subject will be required to look directly at the camera throughout the data collection process. The 'By Face' data collection mode can be performed on both iOS and Android in parallel, with both devices positioned in front of the subject. HR and blood pressure will also be measured immediately before and after the app measurement. Data Collection Equipment For vital signs data collection using the "Comestai" application, the study staff will use the following mobile phones for rPPG "By Face" measurements: * Face: Apple internet(i)Phone 13 Pro (10 bit) \& Samsung Galaxy S21 Ultra * Two additional phones will be used as remote: * One Android phone - Recorder Remote to start the measurement from far. * One Apple iPhone -Masimo-finger sensor App to collect the data from the Masimo finger sensor. * Other necessary equipment includes phone stands (two per room of measurement). In addition to the equipment for vital signs data collection using the "Comestai" application, reference devices will measure the subject's vital signs as a point of comparison. rPPG "By Face" vital signs data collection includes videoing the subjects' faces with a mobile device (iOS and Android) front camara for approximately 1.5 minutes. Vital signs data using the reference devices (i.e., SpO2, RR, BP, PR) will be collected continuously for approximately 1.5 minutes, and simultaneously to the data collected using the "Comestai" application (i.e., "By Face"). Several data collection events (1.5 minutes each) may be performed per subject using the "Comestai" application and reference devices. BP will be collected using the reference devices prior to data collection using the Comestai application and immediately after completion of data collection using the Comestai application. During "By Face" data collection, the subjects will be requested to sit in a comfortable place, looking at a screen (distance of \~25cm) with a fully exposed face (not to wear a mask, hat, or any kind of accessory on the face). During data collection, the subject breathing should be stable with minimum movements. The subject will be requested to stare directly towards the camara during the whole data collection process. "By Face" mode of data collection can be taken for both iOS and Android in parallel when both devices are positioned in front of the subject. During the "By Face" data collection, SpO2 levels will be monitored continuously using the standard reference device. Consent will be sought for viewing and collecting the results of pre-scheduled blood tests. Participation is optional, and subjects who do not consent can still proceed with the parameter measurements. In case of acceptance, the following results will be considered: Complete Blood Count (Hemoglobin, White Blood Cell Count, Neutrophils, Lymphocytes, and Platelets), Hemoglobin Glycosylated (HbA1C), Lipid Profile (Total Cholesterol, Cholesterol-LDL, Cholesterol-HDL, and Triglycerides), Glucose, Alanine transaminase (ALT), Creatinine. Estimated participation time per subject: approximately 10-15 minutes. No medical decisions will be based on data obtained through the "Comestai" application, reference devices, or blood sample results. All data will be recorded in the study's eCRF. The analysis plan involves verifying and validating the parameters collected from mobile devices via the app and from reference devices, as well as results of pre-scheduled blood tests and patient demographic data. For all parameters, the accuracy of the app measurement compared to the reference device and standard tests will be assessed. Confidence intervals will be calculated using the bootstrap method. The correlation between measurements using the app and those using reference devices and standard tests will be evaluated using the Pearson correlation coefficient. The agreement between the two measurements (app and reference devices/and standard tests) will be represented using Bland-Altman plots.

Registry
clinicaltrials.gov
Start Date
June 1, 2024
End Date
January 1, 2026
Last Updated
5 months ago
Study Type
Observational
Sex
All

Investigators

Sponsor
Buzzi Children's Hospital
Responsible Party
Principal Investigator
Principal Investigator

Valeria Calcaterra

Clinical Professor

Buzzi Children's Hospital

Eligibility Criteria

Inclusion Criteria

  • Prior to enrollment in this study, subjects must meet all the following inclusion criteria:
  • Subject must have the ability to understand and provide written informed consent.
  • Male or Female subject ≥16 and ≤65 of age.
  • Subject must be willing and able to comply with study procedures.

Exclusion Criteria

  • Subjects will be excluded from the study if any of the following conditions are present:
  • Subject with compromised circulation, injury, or physical malformation of fingers, hands, ears or forehead/skull or other sensor Region of Interest (ROI) which would limit the ability to test ROI needed for the study.
  • Subject has a tattoo in the optical path which would limit the ability to test ROI needed for the study.
  • Subjects with severe contact allergies to standard adhesives, latex or other materials found in pulse oximetry sensors, respiration monitor electrodes or other medical sensors used for measuring vital signs.
  • Subject with a medical condition which in the opinion of the investigator, does not allow performing the study assessments.
  • Subject unfit to participate in the study to the judgment of the investigator.
  • In addition to the Inclusion/Exclusion criteria, the 70% of target population should include adult subjects with at least one of the following:
  • Pre-diabetes or diabetes HbA1C 5.7-13%
  • \>30% of subjects with HbA1C 5.7-6.4%
  • \>30% of subjects with HbA1C \>6.4%

Outcomes

Primary Outcomes

Data Collection Storage and Processing-Pulse rate

Time Frame: 15 minutes for data collection

Collect, verify and validate Pulse rate (beats per minute) in data using the Comestai application and reference devices. Pulse rate data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results.

Data Collection Storage and Processing-Respiratory rate

Time Frame: 15 minutes for data collection

Collect, verify and validate Respiratory rate (breaths per minute) in data using the Comestai application and reference devices. Respiratory rate data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results.

Data Collection Storage and Processing-Oxygen saturation

Time Frame: 15 minutes for data collection

Collect, verify and validate Oxygen saturation (percentage) in data using the Comestai application and reference devices. Oxygen saturation data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results.

Data Collection Storage and Processing-Blood pressure

Time Frame: 15 minutes for data collection

Collect, verify and validate Blood pressure (mmHg) in data using the Comestai application and reference devices. Blood pressure data obtained using the Comestai application and reference data will be stored on Comestai's secured cloud without any subject identifiable information and will only be recognized using the subject identification number provided during screening. The raw data of subjects' vital signs will be locked, encrypted, and can be read only by Study center team. The measurement method utilized by the app is Remote Photoplethysmography (rPPG). No medical decisions will be made based on the data obtained using the Comestai application, the reference devices, and the pre-scheduled blood sample results.

Secondary Outcomes

  • Data Collection Storage and Processing-Hemoglobin(15 minutes for data collection)
  • Data Collection Storage and Processing-Hemoglobin glycosylated(15 minutes for data collection)