NCT00904358已完成不适用
Validity and Reliability of Non-invasive Estimation of Central Venous Pressure by Measurement of Internal Jugular Size Using 2-dimensional Ultrasound
适应症
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 130
- 试验地点
- 2
- 主要终点
- internal jugular size
研究概览
简要总结
To study the validity and reliability of estimation of the central venous pressure by measurement of internal jugular vein size using 2-dimensional ultrasound.
详细描述
Objectives:
- To study the validity and reliability of estimation of the central venous pressure by measurement of internal jugular vein size using 2-dimensional ultrasound.
- To evaluate the correlation of internal jugular vein cross sectional area and central venous pressure.
Methods:
- The study design is prospective observational study.
- We will include all patients scheduled for cardiac surgery in Siriraj Hospital and record both internal jugular size using 2-dimensional ultrasound just before central venous catheter insertion. The central venous pressure will be recorded and the ultrasound picture will be measured.
- The data will be analyzed.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •patients scheduled for cardiac surgery
- •need central venous catheterization intraoperatively
- •elective surgery
- •age > 18
排除标准
- •neck pathology
- •history of internal jugular or SVC thrombosis
- •limited neck mobility
- •severe valvular lesion
- •decompensated heart failure
结局指标
主要结局
internal jugular size
时间窗: 1 day
Cross-sectional area of internal jugular vein measured by ultrasound
次要结局
未报告次要终点
研究者
研究点 (2)
Loading locations...
相似试验
已完成
不适用
Correlation of Measurements From Mespere Venus 1000 System & Echocardiography to Estimate Right Atrial PressurePatients Referred to St. Michael's Hospital Echocardiography LabNCT01623986Mespere Lifesciences Inc.45
已完成
不适用
Non-invasive Assessments of Central Venous PressureVenous Pressure, CentralUltrasonic DiagnosisNCT01079611University Hospital, Basel, Switzerland81
已完成
不适用
Central Venous Pressure (CVP) Assessment by Ultrasound and Physical ExaminationCentral Venous PressureNCT01099241University of Iowa38
Unknown
不适用
Validation of Non-Invasive Intracranial Pressure (ICP) Monitoring DeviceIntracranial HypertensionAbnormality of Intracranial PressureNCT03865576Boston Neurosciences80
终止
不适用
Reliability of Central Venous Pressure MeasurementsHemodynamicsCentral Venous PressureNCT01116973University of Oklahoma17
