Avidhrt Clinical Equivalence Study
- Conditions
- Equivalence of ECG Electrode Type Signal Quality for AF and Non AF Users
- Interventions
- Device: Avidhrt Sense Heart Monitor
- Registration Number
- NCT05357209
- Lead Sponsor
- Avidhrt Inc.
- Brief Summary
The Avidhrt Clinical Equivalence Study will test and evaluate the equivalency between ECG signals acquired simultaneously using the Avidhrt Sense Lead-1 ECG, and an FDA cleared Lead-12 gel ECG. The Avidhrt Clinical Equivalence Study also includes a sub-study. The Avidhrt Sense Human Factors sub-study will evaluate the usability and efficacy of the user-interface of the Avidhrt Sense device.
- Detailed Description
This study will test the clinical equivalency of an Avidhrt Sense acquired Lead-I ECG signal and a Lead-I ECG signal obtained from an FDA cleared 12-lead-ECG gel electrode.The Avidhrt Clinical Equivalence study is comprised of study Arm A and Arm B. In Arm A of this study the population is comprised exclusively of subjects with AF, who will be asked to participate in the Clinical Equivalence Study and in the Human Factors Sub-Study. In Arm B of this study the population will consist of all other subjects (no AF), who will be asked to participate in the Clinical Equivalence Study, with the option to enroll and participate in the Human Factors Sub-Study. This is a prospective, parallel-cohort, non-randomized study using an enriched population.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 75
- Adults ≥ 22 years old at the time of enrollment
- Capable of giving informed consent
- Sufficient manual dexterity to capture an ECG using Avidhrt Sense
- Subjects in the arrhythmia group must have a known history of arrhythmia, and may have an arrhythmia at the time of enrollment based on the screening ECG just before the study recordings are taken.
- Cardiac pacemaker or implantable cardioverter-defibrillator
- History of a life-threatening rhythm such as ventricular tachycardia or ventricular fibrillation
- Anti-arrhythmic (rhythm control) medication use (such as amiodarone or flecainide)
- Subjects in the normal controls group should not have any history of arrhythmia and should not be in arrhythmia at the time of enrollment based on the screening ECG
- Subjects with tremors who are unable to stably hold the Avidhrt Sense during a recording without movement
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Arm A Avidhrt Sense Heart Monitor Arm A of the Avidhrt study will contain subjects that have been/are diagnosed with AF. Arm A of the study will have the participants complete the Human Factors sub-study in addition to the primary clinical study. Arm B Avidhrt Sense Heart Monitor Arm B of the Avidhrt study will contain all other subjects (those non diagnosed with AF), and participants will receive the option whether to participate in the Human Factors sub-study.
- Primary Outcome Measures
Name Time Method Avidhrt Sense ECG equivalency 12 months
- Secondary Outcome Measures
Name Time Method