MedPath

A Study to Address Precision and Refractive Predictability of Femtosecond Laser-assisted Astigmatic Keratotomy Following the Cataract Surgery

Not Applicable
Completed
Conditions
Astigmatism
Interventions
Device: arcuate incision
Registration Number
NCT01752218
Lead Sponsor
Technolas Perfect Vision GmbH
Brief Summary

The purpose of this open, prospective study is to address the effectiveness and precision of the VICTUS™ Femtosecond Laser Platform-assisted astigmatic keratotomy after femtolaser-assisted cataract surgery.

Detailed Description

Corneal astigmatism after cataract surgery represents a considerable obstacle in the visual rehabilitation of patients. Up-to-date astigmatic keratotomy represents a standardized and effective procedure that allows decreasing of naturally occurring and surgically induced astigmatism. The shape and architecture of the Arcuate Incisions are pre-calculated based on a particular chosen nomogram. The different parameters of the Arcuate Incisions as radius, opening and position angle and cutting depth can be achieved precisely by the laser technology.

The laser-assisted Cataract surgery and the Arcuate Incisions are performed by means of a femtosecond laser (VICTUS™ FEMTOSECOND LASER PLATFORM®, Technolas Perfect Vision GmbH, Munich, Germany) which is in the presented study under investigation and is already CE-approved.

For this open, prospective data collection several selection criteria have been defined in order to obtain a data set of minimal 43 eyes and maximal 50 eyes. Depending on whether they will be treated unilateral or bilateral the number of subjects enrolled within this study sums up to 22-50 patients. The data is gathered in the Castrop-Rauxel Augenklinik and only from one experienced surgeon.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
43
Inclusion Criteria
  • Clear corneal media

  • Patients must be at least 40 years of age

  • mono- or bilateral Cataract with uncorrected distance visual acuity (UCDVA)

    • 0.63 or glare sensitivity
  • Vectorial averaged astigmatism of keratometric and topographic astigmatism:

    • 1.0 D and ≤ 2.0 D
  • Patients must have read, understood the Patient Information and signed the informed consent form

  • Patients are willing and able to return for follow-up examinations

Exclusion Criteria
  • The maximum K- value may not exceed 60D, the minimal value may not be smaller than 37D
  • Pachymetry does not include examination results at an radius of 4.25 mm
  • Corneal disease or pathology, such as corneal scaring or opacity, that precludes transmission of laser wavelength or that distorts laser light
  • Subjects with a poorly dilating pupil or other defect of the pupil that prevents the iris from adequate retraction peripherally
  • Lens/zonular instability such as, but not restricted to, Marfan's Syndrome, Pseudoexfoliation Syndrome, etc.
  • Manifest Glaucoma
  • Previous intraocular or corneal surgery of any kind, including any type of surgery for either refractive or therapeutic purposes in either eye
  • Known sensitivity to planned concomitant medications
  • Patients regularly taking medicines that could influence the result of the treatment respectively the vision
  • Patients with disorders of the ocular muscle, such as nystagmus or strabismus
  • Patients with keratoconus, keratectasia or other irregular cornea changes
  • Patients with connective tissue weakness
  • Patients who are blind on one eye
  • Subjects who are immune compromised or carrying diagnosis of connective tissue disease, clinically significant atopic disease, insulin dependent diabetes mellitus, autoimmune diseases, ocular herpes zoster or simplex, endocrine diseases, lupus, rheumatoid arthritis, collagenosis and other acute or chronic illnesses that will increase the risk to the subject or confound the outcomes of this study.
  • Abnormal examination results from slit lamp, fundus examination or IOL Master, age related changes are acceptable
  • Patients with eye diseases which decreases the visual acuity such as macular degeneration, macular edema, proliferative diabetic Retinopathy
  • Abnormal examination results from Topography, age related changes are acceptable
  • Patients who are pregnant or nursing
  • Patients with concentration disorders, epilepsy and other complicating diseases
  • Patients who are participating in another clinical study 30 days before

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Arcuate Incisionarcuate incisionStudy arm will consist of patients who show cataract and corneal astigmatism.
Primary Outcome Measures
NameTimeMethod
subjective cylinder3 month postoperative

At the 3 month visit the subjective cylinder as measured with phoropter or trial frame is ≤ 0.75 D in 60% of the eyes.

Secondary Outcome Measures
NameTimeMethod
topographic corneal cylinder3 month postoperative

At the 3 month visit the value of postoperative corneal astigmatism of the central 3 mm zone, measured with topography, is ≤ 1.0 D in 60% of the eyes

abberrometric corneal astigmatism3 month postoperative

At the 3 month visit the value of postoperative corneal astigmatism of the central 3 mm zone, measured with aberrometry, is ≤ 1.0 D in 60% of the eyes.

keratomic corneal astigmatism3 month postoperative

At the 3 month visit the value of postoperative corneal astigmatism of the central 3 mm zone, measured with keratometry, is ≤ 1.0 D in 60% of the eyes

correction index based on keratometric corneal astigmatism3 month postoperative

At 3 month visit the value of the correction index based on preoperative and postoperative keratometric corneal astigmatism is 0.9+- 0,35 in 70% of the eyes.

correction index based on3 month postoperative

At 3 month visit the value of the correction index based on preoperative keratometric corneal astigmatism and postoperative subjective astigmatism is 0.9+- 0,35 in 70% of the eyes.

Trial Locations

Locations (1)

Augen- & Laserklinik Castrop-Rauxel GmbH

🇩🇪

Castrop-Rauxel, Germany

© Copyright 2025. All Rights Reserved by MedPath