Evaluation of Fluid-Filled Expression Core Technology Study - I
- Conditions
- Breast Pumping
- Interventions
- Device: Breast Pump
- Registration Number
- NCT03921918
- Lead Sponsor
- Medela AG
- Brief Summary
A functional model of a fluid-filled, smaller dead volume breast pump has been developed in order to more closely mimic the breastfeeding infant. The technology of fluid-filled pumping has been tested in one prior clinical study and has now progressed to a complete prototype with which the user can assemble, pump, disassemble, clean and reuse.
- Detailed Description
Current breast pumps function in a way that is different to breastfeeding. These include the seal to the breast, the movement of the nipple, the sensations of warmth and moisture, the variability in frequency, and the strength of the applied vacuum. During breastfeeding the mother's nipple and the infant's mouth form a chamber that is a fluid-filled, no dead volume system, which is needed to create a working vacuum to remove milk from the breast. There is no air visible in the natural system according to ultrasound measurements. This is unlike breast pumps which use an air-filled, large dead volume system, to create a working vacuum. Therefore, a functional model of a fluid-filled, smaller dead volume breast pump has been developed in order to more closely mimic the breastfeeding infant. The technology of fluid-filled pumping has been tested in one prior clinical study and has now progressed to a complete prototype with which the user can assemble, pump, disassemble, clean and reuse.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Female
- Target Recruitment
- 26
- Subject ≥ 18 years old
- Infant is ≥1 and ≤6 month old
- Subject and baby are healthy according to self-declaration in the "Mother and infant health questionnaire"
- Subject is predominantly breastfeeding (80% of all feeds, i.e. ≤150 ml formula/day or equal representative amount of solid food)
- The subject agrees to pump or feed the last time a minimum of 2 hours (hr) before the start of the pumping session at the study site
- The subject agrees to photographs/3 D scan of the breast and upper body (no face),
- The subject agrees to a video while pumping
- The subject signs the informed consent documentation
- Subject agrees that a maximum of 2 male team members can be present in the room to conduct the usability part of the study
- The mother accepts that the pumped milk in visit 2 must be donated to the study i.e. cannot be fed to the baby
- The subject has a nipple size ≥ 21 mm
- Mastitis (any breast within two weeks prior to enrolment)
- Engorgement (any breast within two weeks prior to enrolment).
- Case of current infection as self-declared in the Mother and infant health questionnaire
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Evaluation of Fluid Expression Technology Breast Pump This study aims to provide important insights with respect to the safety, performance, and real-life usability of pumping technology
- Primary Outcome Measures
Name Time Method Recording all Adverse Events 3 months Recording all AE and evaluating the (time of) occurrence, type, seriousness, expectedness, relatedness, and outcome of the adverse events
Observing pump performance 3 months Measuring milk flow volume including time to first ejection.
- Secondary Outcome Measures
Name Time Method Measureing user acceptance 3 months Analysing the User Experience Questionnaire as per Laugwitz, Held \& Schrepp (2017)
Trial Locations
- Locations (1)
Medela AG
🇨🇭Baar, Switzerland