Skip to main content
Clinical Trials/NCT04509453
NCT04509453CompletedNot Applicable

Comparison Between McGRATH and Macintosh Laryngoscopy in Laryngeal Mask Airway Insertion

Udayana University2 sites in 1 country102 target enrollmentStarted: August 30, 2020Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Sponsor
Enrollment
102
Locations
2
Primary Endpoint
Number of participants with first-attempt success

Study Overview

Brief Summary

Various techniques have been developed to get a good LMA position, one of them is using a laryngoscope. The most popular laryngoscope used for LMA installation is the Macintosh type. Technological developments have brought laryngoscopes into the video era, one of which is McGRATH's laryngoscope, which from several studies about having an advantage in terms of the first attempt, time, complications, and hemodynamic stability of intubation. It needs to be proven through research on the comparison of clinical outcomes of LMA installation with McGrath laryngoscope and Macintosh laryngoscope.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Other
Masking
Double (Participant, Investigator)

Eligibility Criteria

Ages
18 Years to 65 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Patients underwent surgery with general anesthesia by LMA insertion in Sanglah General Hospital
  • Agreed to be included in the study by signing informed consent
  • American Society of Anesthesiologist physical status 1-2

Exclusion Criteria

  • Patients unfit for LMA insertion
  • Patients with suspected airway management difficulty
  • Pregnancy
  • Morbid obese

Outcomes

Primary Outcomes

Number of participants with first-attempt success

Time Frame: immediately after LMA insertion

Successful LMA insertion within first attempt

Heart rate

Time Frame: immediately after LMA insertion

Heart rate measured by standard monitor

Mean arterial pressure

Time Frame: immediately after LMA insertion

Mean arterial pressure measured by non-invasive blood pressure monitor

Secondary Outcomes

  • Complications(An hour after the the end of surgery)
  • Time required(immediately after LMA insertion)

Investigators

Sponsor
Udayana University
Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Christopher Ryalino

Principal Investigator

Udayana University

Study Sites (2)

Loading locations...

Similar Trials