MedPath

Pneumatic Displacement of Subretinal Hemorrhage With Perfluorocarbon Gases

Phase 2
Conditions
Subretinal Hemorrhage and Exudative Maculopathy
Registration Number
NCT00161525
Lead Sponsor
Weill Medical College of Cornell University
Brief Summary

Subretinal hemorrhage in the macula causes a significant loss of vision. This hemorrhage can be displaced by the use of a small volume of pure perfluorocarbon gas injected into the vitreous, which expands to a 40% gas bubble in the eye. When the patient gazes 40 to 60 degree below the horizontal, the gas bubble covers the hemorrhage and gravity displaces it rapidly. This position of gaze is easier for the patient than the face down position traditionally recommended.A vector of gravity force tangential to the sclera brings about this displacement. The procedure can improve vision quickly, reduce unwanted degenerative changes in the macula because of the persistent macular hemorrhage and improves the chances of treating of the underlying cause for the subretinal hemorrhage by laser or other means.

Detailed Description

This protocol was designed to determine the optimum position of the gaze for pneumatic displacement of subretinal hemorrhage (SRH) in the macula. A geometrical analysis of the forces that act upon a SRH in the presence of an intraocular gas bubble was analyzed and it was concluded that the displacement was due to the effect of gravity on the SRH immersed in gas. This was followed by a prospective trial of positions of gaze and volumes of gas calculated to be optimum for displacement. The eyes of consecutive patients with SRH in the macula will had an intravitreal injection of pure perfluorocarbon gas sufficient to provide a 40% bubble after expansion. The patients are instructed to gaze down 40° or 60° below the horizontal depending on the volume of gas for 20 minutes every hour. The SRH is displaced rapidly in the first week. Visual acuity usually improves but recovery can be limited by the presence of sub pigment epithelial hemorrhage, exudate or proliferation. A vector of the gravity force tangential to the sclera is the largest force acting to displace a subretinal hemorrhage within a gas bubble. 79% of the vertical gravity component is obtained at gaze 40° below the horizontal and requires volumes of intraocular gas not requiring prior removal of vitreous. Face down positioning in common practice has been an error and succeeds only if the patient has been non compliant.

5- STATUS

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
25
Inclusion Criteria
  • Diminished vision secondary to subretinal hemorrhage in the macula or exudative maculopathy.
Exclusion Criteria
  • Patient unable to maintain gaze position for 20 minutes every waking hour for 7 days.
  • Patient unable to sleep on their side or with head elevated 40 degrees.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
Displacement of Subretinal Hemorrhage7 days after gas injection
Secondary Outcome Measures
NameTimeMethod
Improvement in visual acuity7 days after gas injection

Trial Locations

Locations (1)

New York Presbyterian Hospital

🇺🇸

New York, New York, United States

© Copyright 2025. All Rights Reserved by MedPath