Triamcinolone Acetonide
Triamcinolone Acetonide Cream USP, 0.025%, 0.1%, 0.5% Rx only
3597dccf-079c-5cd9-e063-6294a90aca71
HUMAN PRESCRIPTION DRUG LABEL
May 20, 2025
NuCare Pharmaceuticals, Inc.
DUNS: 010632300
Products 1
Detailed information about drug products covered under this FDA approval, including NDC codes, dosage forms, ingredients, and administration routes.
Triamcinolone Acetonide
Product Details
FDA regulatory identification and product classification information
FDA Identifiers
Product Classification
Product Specifications
INGREDIENTS (8)
Drug Labeling Information
PACKAGE LABEL.PRINCIPAL DISPLAY PANEL
PACKAGE LABEL.PRINCIPAL DISPLAY PANEL
INDICATIONS & USAGE SECTION
INDICATIONS & USAGE:
Triamcinolone Acetonide Cream is indicated for the relief of the inflammatory and pruritic manifestations of corticosteroid-responsive dermatoses.
CONTRAINDICATIONS SECTION
CONTRAINDICATIONS:
Topical corticosteroids are contraindicated in those patients with a history of hypersensitivity to any of the components of the preparation.
ADVERSE REACTIONS SECTION
ADVERSE REACTIONS:
The following local adverse reactions are reported infrequently with topical corticosteroids, but may occur more frequently with the use of occlusive dressings. These reactions are listed in an approximate decreasing order of occurrence: burning, itching, irritation, dryness, folliculitis, hypertrichosis, acneiform eruptions, hypopigmentation, perioral dermatitis, allergic contact dermatitis, maceration of the skin, secondary infection, skin atrophy, striae and miliaria.
PRECAUTIONS SECTION
PRECAUTIONS:
General:
Systemic absorption of topical corticosteroids has produced reversible
hypothalamic pituitary-adrenal (HPA) axis suppression, manifestations of
Cushing’s syndrome, hyperglycemia, and glucosuria in some patients.
Conditions which augment systemic absorption include the application of the
more potent steroids, use over large surface areas, prolonged use, and the
addition of occlusive dressings.
Therefore, patients receiving a large dose of any potent topical steroid
applied to a large surface area or under an occlusive dressing should be
evaluated periodically for evidence of HPA axis suppression by using the
urinary free cortisol and ACTH stimulation tests, and for impairment of
thermal homeostasis. If HPA axis suppression or elevation of the body
temperature occurs, an attempt should be made to withdraw the drug, to reduce
the frequency of application, substitute a less potent steroid, or use a
sequential approach when utilizing the occlusive technique.
Recovery of HPA axis function and thermal homeostasis are generally prompt and
complete upon discontinuation of the drug. Infrequently, signs and symptoms of
steroid withdrawal may occur, requiring supplemental systemic corticosteroids.
Occasionally, a patient may develop a sensitivity reaction to a particular
occlusive dressing material or adhesive and a substitute material may be
necessary.
Children may absorb proportionally larger amounts of topical corticosteroids
and thus be more susceptible to systemic toxicity (see PRECAUTIONS, Pediatric
Use).
If irritation develops, topical corticosteroids should be discontinued and
appropriate therapy instituted.
In the presence of dermatological infections, the use of an appropriate
antifungal or antibacterial agent should be instituted. If a favorable
response does not occur promptly, the corticosteroid should be discontinued
until the infection has been adequately controlled.
These preparations are not for ophthalmic use.
Information for the Patient:
Patients using topical corticosteroids should receive the following
information and instructions.
1. This medication is to be used as directed by the physician. It is for
dermatologic use only. Avoid contact with the eyes.
2. Patients should be advised not to use this medication for any disorder
other than for which it was prescribed.
3. The treated skin area should not be bandaged or otherwise covered or
wrapped as to be occlusive unless directed by the physician.
4. Patients should report any signs of local adverse reactions especially
under occlusive dressing.
5. Parents of pediatric patients should be advised not to use tight-fitting
diapers or plastic pants on a child being treated in the diaper area, as these
garments may constitute occlusive dressings.
Laboratory Tests:
A urinary free cortisol test and ACTH stimulation test may be helpful in evaluating HPA axis suppression.
Carcinogenesis, Mutagenesis, and Impairment of Fertility:
Long-term animal studies have not been performed to evaluate the carcinogenic potential or the effect on fertility of topical corticosteroids. Studies to determine mutagenicity with prednisolone and hydrocortisone have revealed negative results.
Pregnancy:
Teratogenic Effects Category C.
****Corticosteroids are generally teratogenic in laboratory animals when
administered systemically at relatively low dosage levels. The more potent
corticosteroids have been shown to be teratogenic after dermal application in
laboratory animals. There are no adequate and well controlled studies in
pregnant women on teratogenic effects from topically applied corticosteroids.
Therefore, topical corticosteroids should be used during pregnancy only if the
potential benefit justifies the potential risk to the fetus. Drugs of this
class should not be used extensively on pregnant patients, in large amounts,
or for prolonged periods of time.
Nursing Mothers:
It is not known whether topical administration of corticosteroids could result in sufficient systemic absorption to produce detectable quantities in breast milk. Systemically administered corticosteroids are secreted into breast milk in quantities not likely to have a deleterious effect on the infant. Nevertheless, caution should be exercised when topical corticosteroids are administered to a nursing woman.
Pediatric Use:
Pediatric patients may demonstrate greater susceptibility to topical
corticosteroid-induced HPA axis suppression and Cushing's syndrome than mature
patients because of a larger skin surface area to body weight ratio.
Hypothalamic-pituitary-adrenal (HPA) axis suppression, Cushing's syndrome, and
intracranial hypertension have been reported in children receiving topical
corticosteroids.
Manifestations of adrenal suppression in children include linear growth
retardation, delayed weight gain, low plasma cortisol levels, and absence of
response to ACTH stimulation. Manifestations of intracranial hypertension
include bulging fontanelles, headaches, and bilateral papilledema.
Administration of topical corticosteroids to children should be limited to the
least amount compatible with an effective therapeutic
regimen. Chronic corticosteroid therapy may interfere with the growth and
development of children.
DESCRIPTION SECTION
DESCRIPTION:
The topical corticosteroids constitute a class of primarily synthetic steroids used as anti-inflammatory and anti-pruritic agents. The steroids in this class include triamcinolone acetonide.
Triamcinolone Acetonide Cream USP contains Triamcinolone Acetonide [Pregna-1,4-diene-3,20-dione,9-fluoro-11,21-dihydroxy-16,17-[(1-methylethylidene) bis- (oxy)]-, (11β,16α)-], with the empirical formula C 24H 31FO 6and molecular weight 434.50. CAS 76-25-5.
The structural formula is:
Triamcinolone Acetonide Cream USP, 0.025% contains: 0.25 mg of Triamcinolone
Acetonide, USP per gram in a base containing Emulsifying Wax, Cetyl Alcohol,
Isopropyl Palmitate, Sorbitol Solution, Glycerin, Lactic Acid, Benzyl Alcohol
and Purified Water.
Triamcinolone Acetonide Cream USP, 0.1% contains: 1 mg of Triamcinolone
Acetonide, USP per gram in a base containing Emulsifying Wax, Cetyl Alcohol,
Isopropyl Palmitate, Sorbitol Solution, Glycerin, Lactic Acid, Benzyl Alcohol
and Purified Water.
Triamcinolone Acetonide Cream USP, 0.5% contains: 5 mg of Triamcinolone
Acetonide, USP per gram in a base containing Emulsifying Wax, Cetyl Alcohol,
Isopropyl Palmitate, Sorbitol Solution, Glycerin, Lactic Acid, Benzyl Alcohol
and Purified Water.
CLINICAL PHARMACOLOGY SECTION
CLINICAL PHARMACOLOGY:
Topical corticosteroids share anti-inflammatory, anti-pruritic and vasoconstrictive actions. The mechanism of anti-inflammatory activity of the topical corticosteroids is unclear. Various laboratory methods, including vasoconstrictor assays, are used to compare and predict potencies and/or clinical efficacies of the topical corticosteroids. There is some evidence to suggest that a recognizable correlation exists between vasoconstrictor potency and therapeutic efficacy in man.
Pharmacokinetics:
****The extent of percutaneous absorption of topical corticosteroids is
determined by many factors including the vehicle, the integrity of the
epidermal barrier, and the use of occlusive dressings. Topical corticosteroids
can be absorbed from normal intact skin. Inflammation and/or other disease
processes in the skin increase percutaneous absorption. Occlusive dressings
substantially increase the percutaneous absorption of topical corticosteroids.
Thus, occlusive dressings may be a valuable therapeutic adjunct for treatment
of resistant dermatoses (SeeDOSAGE AND ADMINISTRATION). Once absorbed
through the skin, topical corticosteroids are handled through pharmacokinetic
pathways similar to systemically administered corticosteroids. Corticosteroids
are bound to plasma proteins in varying degrees. Corticosteroids are
metabolized primarily in the liver and are then excreted by the kidneys. Some
of the topical corticosteroids and their metabolites are also excreted into
the bile.
OVERDOSAGE SECTION
OVERDOSAGE:
Topically applied corticosteroids can be absorbed in sufficient amounts to produce systemic effects (See PRECAUTIONS).
DOSAGE & ADMINISTRATION SECTION
DOSAGE & ADMINISTRATION:
Apply Triamcinolone Acetonide Cream 0.025% to the affected area two to four times daily. Rub in gently.
Apply the 0.1% or the 0.5% Triamcinolone Acetonide Cream, as appropriate, to the affected area two to three times daily. Rub in gently.
Occlusive Dressing Technique
Occlusive dressings may be used for the management of psoriasis or other recalcitrant conditions. Gently rub a small amount of cream into the lesion until it disappears.
Reapply the preparation leaving a thin coating on the lesion, cover with pliable nonporous film, and seal the edges. If needed, additional moisture may be provided by covering the lesion with a dampened clean cotton cloth before the nonporous film is applied or by briefly wetting the affected area with water immediately prior to applying the medication. The frequency of changing dressings is best determined on an individual basis. It may be convenient to apply triamcinolone acetonide cream under an occlusive dressing in the evening and to remove the dressing in the morning (i.e., 12-hour occlusion). When utilizing the 12-hour occlusion regimen, additional cream should be applied, without occlusion, during the day. Reapplication is essential at each dressing change. If an infection develops, the use of occlusive dressings should be discontinued and appropriate antimicrobial therapy instituted.
HOW SUPPLIED SECTION
HOW SUPPLIED:
Triamcinolone Acetonide Cream USP, 0.1%
80 gram tubes NDC 68071-3852-8
Store at 20° to 25°C (68° to 77°F); excursions permitted to 15° to 30°C (59° to 86°F) [See USP Controlled Room Temperature]. Avoid excessive heat.
PROTECT FROM FREEZING.
Manufactured for:
Northstar Rx LLC.
Memphis, TN 38141.
Manufactured by:
Macleods Pharmaceuticals Limited
At Oxalis Labs
Baddi, Himachal Pradesh, INDIA
To report SUSPECT ADVERSE REACTIONS, contact NorthStar Rx LLC 1-800-206-7821 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch
Revised: December 2023