跳至主要内容
临床试验/NCT03493971
NCT03493971已完成不适用

Impact of Carotid Endarterectomy and Stenting on Hemodynamics, Fluid-structure Interaction, Autonomic Modulation, and Cognitive Brain Function

Ospedale San Donato2 个研究点 分布在 1 个国家目标入组 70 人开始时间: 2018年3月21日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
70
试验地点
2
主要终点
R-R interval (sec) and Systolic Arterial Pressure (SAP) (mmHg) in rest and tilt position for baroreceptor function

研究概览

简要总结

Carotid revascularization procedures are performed for more than 87% of cases in patients with asymptomatic internal carotid stenosis (ICS), who are assumed to have a life expectancy of at least 5 years. Hence, the investigators aim to compare carotid artery stenting (CAS) with carotid endarterectomy (CEA) in terms of long-term prognostic endpoints in patients with uneventful perioperative course. CEA and CAS, as a consequence of either surgical trauma or mechanical stimuli related to the compliance mismatch between the stented segment and the native artery, may perturb carotid baroreceptors function causing an impairment of cardiovascular autonomic control. Also, CEA and CAS result in different postoperative geometric features of carotid arteries that entail relevant modifications of rheological parameters, that may be associated with the risk of local complications. Finally, long-term and sustained cognitive benefits after CAS as compared to CEA are yet to be demonstrated.

详细描述

Hypothesis and Significance: Late clinical outcome and prognosis after CAS may be inferior to that after CEA in terms of autonomic modulation, hemodynamic remodeling, and cognitive function.

Specific Aim: 1) To compare the impact of CEA and CAS on long-term post-operative baroreceptor function and on cognitive brain function, and analyze their influence on clinical outcome. The specific goal is to assess the potential correlation between post-operative autonomic and cognitive function. 2) To assess the solicitation on the carotid wall due to CAS as compared to CEA through structural analysis and mechanical modeling. The specific goal is to assess the potential correlation between stenting, wall damage, baroceptor impairment, and late neurological sequelae. 3) To assess the post-operative carotid hemodynamics combining medical image analysis, clinical data, and computer simulations. The specific goal aims at correlating both local (e.g., wall stress stress) and global phenomena (controlateral flow, arterial stiffening) with baroreflex function and post-operative neurological outcomes.

Experimental Design Aim 1: A computerized method requiring small operator interaction will be used to assess indices of autonomic sympathovagal balance directed to the sinoatrial node, sympathetic vasomotor modulation, and baroreflex gain, all from spontaneous beat-by-beat variations of the R-R interval and systolic arterial pressure (SAP) variability, considering only sinus rhythm conditions. After electrode and sensor positioning, patients will be maintained for 10 minute in resting supine position, necessary for stabilization, subsequently blood pressure waveforms, electrocardiogram and respiratory activity will be continuously recorded during a nominal 5-minute baseline and then for subsequent 5-minute period of active standing.

Cardiovascular signals will be acquired by a 4 channel digital polygraph. The electrocardiogram will be recorded with two electrodes placed on the patient's chest, breathing pattern will be recorded by a piezoelectric belt and finger arterial blood pressure will be continuously monitored by a CNAP 500 HD continuous noninvasive hemodynamics monitor (CNSystems Medizintechnik AG, Austria). As described previously, (8) a series of indexes indirectly reflecting autonomic cardiovascular modulation will be derived from the spectral analysis of R-R interval and SAP variability. Postoperative cardiovascular autonomic control will be correlated to clinical outcome and measures of cognitive performance. Enrolled patients will be submitted to Mini-Mental State Examination for general cognitive impairment screening. Cognitive P300 evoked potentials will be then recorded, before and after treatment, with Ag/AgCl electrodes with a Brain Vision Recorder (Brain Products GmbH, Gilching, Germany). P300 evoked potentials will be generated after a binaurally presented tone discrimination paradigm (odd-ball paradigm) with frequent (80%) tones of 1000 Hz and rare (20%) target tones of 2000 Hz at 75 dB HL. Filter bandpass will be 0.01 to 30 Hz. Active electrodes will be placed at Cz (vertex) and Fz (frontal), respectively, and referenced to linked earlobe A1/2 electrodes (10/20 international system). During the paradigm, the patients will be instructed to keep a running mental count of the rare 2000-Hz target tones. To verify attention, P300 recordings with a discrepancy of>10% between the actual number of stimuli and the number counted by the patients will be rejected and repeated. P300 evoked potential recording will result in a stable sequence of positive and negative peaks. Latencies in milliseconds (ms) of the cognitive P300 peak will be assessed. To confirm reproducibility, two sets of P300 measurements will be recorded for all patients.

Experimental Design Aim 2: The computer-based simulation of CAS is performed exploiting a computational framework, which can be used to analyze both stent apposition and vessel wall stress in a virtual manner. The framework accounts for two main parts: the vessel model and stent model. Preoperative and postoperative medical images (including high resolution Contrast Enhanced (CE)-MRI and Computed Tomography Angiography (CTA)) will represent the input to build a patient specific carotid model. The 3D lumen profile of the vessel is reconstructed through the segmentation of DICOM image stack using tools like ITK-SNAP (www.itksnap.org) or VMTK (www.vmtk.org). The computational domain (the so-called mesh), used to solve the equilibrium equations governing the structural stent-vessel interaction, is created by an in-house developed procedure, coded in Matlab (The Mathworks Inc., Natick,MA, USA). The non-linear mechanical response of the arterial tissue is reproduced adopting an anisotropic hyperelastic strain-energy function, accounting for two families of fibers, oriented along a preferred direction with a certain degree of dispersion. The model parameters will be calibrated with respect to experimental tensile tests of the carotid tissue. The arterial model is then assembled in the simulation environment with a given stent model, picked from a predefined library of stent designs (the stent mesh generation is based on geometrical measurements performed on high-resolution micro-CT of stent samples). The CAS simulation is performed through structural finite element analysis (FEA); the commercial FEA solver Abaqus (Simulia, Dassault Systemes, FR), is adopted to run the simulations. The engineering outcomes of the simulations, (i.e. the nodal displacement field, stress tensor and strain at each integration points of the mesh), are elaborated to assess clinically relevant parameters of stenting performance (e.g. lumen gain, vessel straightening, stent cell size). The output will be used as an input of the Computational Fluid Dynamics analysis to evaluate the impact of the implanted design on the local haemodynamics (e.g., wall shear stress, oscillatory shear index, etc). Similarly, the structural analysis of CEA will be performed through the virtual pressurization of the post-operative arterial geometry.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 75 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Informed consent signed
  • Patients with >=70% symptomatic or >=80% asymptomatic internal carotid stenosis

排除标准

  • Incapability to give informed consent
  • Previous disabling stroke
  • Contralateral carotid occlusion or >70% stenosis
  • Systemic disease judged non compatible with the procedures or randomization
  • Suspected or manifested pregnancy
  • General contraindications to MRI or CT studies

结局指标

主要结局

R-R interval (sec) and Systolic Arterial Pressure (SAP) (mmHg) in rest and tilt position for baroreceptor function

时间窗: 20 months

Comparison pre- and post-CAS, Comparison pre- and post-CEA

次要结局

  • Oscillatory index (OSI) (%)(20 months)
  • Flow helicity (-)(20 months)
  • CCA/ICA Flow split (%)(20 months)
  • Time-averaged wall shear stress (TAWSS) (dyn/cm2)(20 months)
  • Systolic wall shear stress (dyn/cm2)(20 months)
  • Cognitive P300 latency (ms)(20 months)
  • Common carotid artery (CCA) - internal carotid artery (ICA) mean and maximum pressure drop (mmHg)(20 months)
  • Mean and maximum flow velocity magnitude (cm/sec) in common carotid artery (CCA) and internal carotid artery (ICA) along the cardiac cycle(20 months)
  • Effective reflecting distance (mm) of pressure wave(20 months)
  • Carotid wall von Mises stress (dyn/cm2) at the systolic peak(20 months)
  • Carotid augmentation index (%) of pressure wave(20 months)
  • Carotid wall maximum principal stress (dyn/cm2) at the systolic peak and corresponding directions (-) Maximum, mean, and min principal strain (-) and corresponding directions (-)(20 months)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Massimiliano M. Marrocco-Trischitta

MD, PhD

Ospedale San Donato

研究点 (2)

Loading locations...

相似试验