EnSite Precision 2.1 Feasibility Study

Abbott Medical Devices0 个研究点目标入组 80 人开始时间: 2017年1月4日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
80
主要终点
Demonstrate feasibility of new algorithms witihn the EnSite Velocity Research Platform (VRP) by assessing the frequency of shift/drift during ablation compared to the current commercial EnSite Precision 2.0.1.

研究概览

简要总结

The objective is to demonstrate feasibility of new 'Magnetic Primary' catheter tracking algorithms within the Velocity Research Platform (VRP) by assessing the frequency of shift/drift during ablation compared to the current commercial EnSite Precision 2.0.1

The secondary objective is to evaluate catheter rendering in the VRP system.

详细描述

This is an acute, multi-center, observational, prospective feasibility study with up to 80 patients at up to 5 centers in Europe.

Data will be simultaneously collected on both the EnSite Precision 2.0.1 and VRP mapping systems for the entire duration of the EP mapping and ablation procedure. This study will not require significant change to the current clinical workflow of the mapping and ablation procedure. The VRP operator will observe both displays in real-time and will enter extensive electronic annotations to the VRP data stream to facilitate retrospective analysis. Examples of annotations include drug administration, patient movement, and the introduction of devices such as an intracardiac Echography (ICE) catheter which are not visible on the EnSite mapping system.

If/when the VRP operator notices events which might be better understood with additional data, he/she might ask the physician to hold a catheter in a stable position for an extra few seconds and/or move the catheter to another position. Examples of such events include catheters appearing outside the 3D model and unrealistic catheter shapes on either display. Compliance with such requests is optional and subject to physician preference.

Retrospective data analysis will focus on characterization of the following:

  • Occurence rates and potential causes for Shift and Drift.
  • Frequency and severity of discrepancies between impedance and magnetic coordinates.
  • Positions of catheters relative to the 3D model.
  • Positions of catheters relative to each other, comparing to fluoroscopic images when available.
  • Shapes of catheters on the research system as the catheters are moved to different locations.
  • Final geometry apprearance on the VRP.
  • Voltage and timing maps appearance on the VRP.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients indicated for a cardiac EP study and ablation procedure using a 3D mapping system.
  • Over 18 years of age
  • Ability to provide informed consent for study participation and be willing and able to comply with the protocol described evaluations.

排除标准

  • Pregnant or possibly pregnant patients

结局指标

主要结局

Demonstrate feasibility of new algorithms witihn the EnSite Velocity Research Platform (VRP) by assessing the frequency of shift/drift during ablation compared to the current commercial EnSite Precision 2.0.1.

时间窗: Up to 12 months

Demonstrate feasibility of new algorithms within the EnSite Velocity Research Platform (VRP) by assessing the frequency of shift/drift during ablation compared to the current commercial EnSite Precision 2.0.1

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor