Effect of Head Elevation on Intracranial Pressure and Cerebral Venous Outflow in Children
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 18
- 试验地点
- 1
- 主要终点
- ICP will be reduced with improvement in cerebral venous outflow which is dependent on intravascular volume status and intrathoracic pressure and each will have their own optimal head position.
研究概览
简要总结
Head injury is the most common cause of mortality and acquired disability in childhood. It is common to elevate the head of patients at risk for increased intracranial pressure, although it is not clear if it is always beneficial. Every severe pediatric traumatic brain injured patient will have an optimal head position that prevents rising pressure in the brain.
详细描述
Head injury is the most common cause of mortality and acquired disability on childhood. Management of children at risk for intracranial hypertension is both complex and increasingly controversial. Also, effect of head position on intracranial pressure, cerebral perfusion pressure, adn cerebral venous outflow in the pediatric population has not been studied. We will examine the effect of head positioning on ICP, CPP, and cerebral venous outflow in pediatric patients at risk for intracranial hypertension. The hypothesis is that ICP will be reduced with improvement in cerebral venous outflow by each patient having their own optimal head position.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Prevention
- 盲法
- None
入排标准
- 年龄范围
- — 至 18 Years(Child, Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Neonates, children, and adolescents
- •Intracranial pressure monitor in place
排除标准
- •Severe multiorgan system failure
- •Hemodynamic instability sufficient to preclude changes in head position
研究组 & 干预措施
1
Single arm--no randomization. All subjects enrolled will have vitals collected and three ultrasounds at different levels of head of the bed elevations.
干预措施: Place HOB in alternate positions from 0-50 degrees. (Procedure)
结局指标
主要结局
ICP will be reduced with improvement in cerebral venous outflow which is dependent on intravascular volume status and intrathoracic pressure and each will have their own optimal head position.
时间窗: As long as ICP is being monitored.
次要结局
未报告次要终点