跳至主要内容
临床试验/NCT05574465
NCT05574465撤回不适用

Esophageal Manometry During Recovery From Endotracheal Intubation

University of California, San Francisco1 个研究点 分布在 1 个国家目标入组 100 人开始时间: 2025年7月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
入组人数
100
试验地点
1
主要终点
The Basal Pressures of patients during High-Resolution Motility/Manometry (HRM):

研究概览

简要总结

  1. An intact pharyngoesophageal reflex is essential to protect the upper airway from aspiration of either mouth contents or regurgitated gastric refluxate. This reflex is essential at protecting the airway in all patients.
  2. In patients, while under medication to tolerate endotracheal intubation, it is postulated that an identifiable upper esophageal sphincter and esophageal peristalsis are not present.
  3. With the cessation of anesthetics, accompanied by the reversal of nerve block, normal pharyngoesophageal peristaltic activity correlates with awakening the patient from anesthesia. This would be identified by the performance of esophageal manometry.
  4. A return of normal verbally stimulated pharyngoesophageal swallowing sequence accurately identifies a safe time to remove endotracheal tubes and/or reverse anesthesia. This verbally stimulated swallowing sequence correlated precisely with the return of objective pharyngoesophageal function.

详细描述

The emergence from routine general deep anesthesia with an endotracheal tube is a potentially dangerous time for patients. Patients cannot reliably maintain competence of the upper esophageal sphincter, thus aspiration of the contents from the mouth or regurgitated material from the stomach can be aspirated into the lungs leading to serious complications. In normal awake individuals the upper esophageal sphincter (also known as the cricopharyngeus or the inferior pharyngeal constrictor) is contracted and relaxes precisely timed with voluntary or involuntary swallowing. The swallowing sequence in normal awake persons begins with 1) the contraction of the upper and middle pharyngeal constrictors, 2) the posterior movement of the tongue and 3) the prompt relaxation of the contracted upper esophageal sphincter. Peristalsis then begins in the body of the esophagus leading contents to the stomach. The above is the normal sequence in humans, a process which maintains absolute separation of the airway and digestive passageways despite being in intimate proximity. During the early period of emergence from anesthesia, the aspiration risk is highest due to the sluggish return of the resting pressure in the upper esophagus and the lack of normal coordination with involuntary swallowing. Thus patients can't protect their airway by maintaining competence and appropriate relaxation of the upper esophageal sphincter. Routine high resolution solid state manometry is a standard routine technique is currently performed in awake patients sitting upright voluntarily requested to swallow small boluses of liquid. The entire sequence of events is studied using high resolution solid state manometry.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 70 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients between 18 and 70 years of age (ASA I or II).
  • Already scheduled for endotracheal tube extubation.
  • Willing and able to give informed consent in either English or Spanish.

排除标准

  • Pregnant, breastfeeding, or unwilling to practice birth control during participation in the study.
  • Presence of a condition or abnormality that in the opinion of the Investigator would compromise the safety of the patient or the quality of the data.
  • Patients not meeting entry criteria above.
  • Refusal to give informed consent.
  • Coagulopathy (INR > 2 and/or platelet count < 100,
  • White Blood Cell count < 5,000/mm3
  • Arrhythmia
  • Serum creatinine > 2 mg/dl
  • Prior known or suspected nasal obstruction.
  • Known or suspected Zenker's diverticulum of esophagus, esophageal stricture, head/neck radiation therapy, hereditary telangiectasis, esophageal varices, cirrhosis.
  • Anticoagulant usage such as heparin or Plavix

研究组 & 干预措施

Manometry Device

Other

At 10 minutes prior to anticipated removal of the endotracheal tube, pass the routine manometry catheter per naris to 30 cms.

干预措施: High resolution solid state manometry (Device)

结局指标

主要结局

The Basal Pressures of patients during High-Resolution Motility/Manometry (HRM):

时间窗: The change in Basal Pressures will be recorded at the end of procedure.

High-resolution manometry (HRM) determination of return of cricopharyngeal function \- Basal Pressures: Upper esophageal sphincter (mmHg) - normal (34-104)

The Residual Pressures of patients during High-Resolution Motility/Manometry (HRM):

时间窗: The change in Residual Pressures will be recorded at the end of procedure.

\- Residual Pressures: Upper esophageal sphincter (mmHg) - normal (\<12.0)

The Wave Duration of patients during High-Resolution Motility/Manometry (HRM):

时间窗: The change in Wave Duration will be recorded at the end of procedure.

\- Motility: Wave Duration (seconds) - normal (2.7-5.4)

次要结局

  • Number of patients completing study.(At the completion of procedure)
  • Percentage of patients agreeing to study versus refusing study.(During enrollment)
  • Duration of HRM(The HRM study of the cricopharyngeus will be measured for the 5 minute time period just before planned endotracheal extubation to the time during extubation and for the 5 minute period just after endotracheal extubation.)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验