跳至主要内容
临床试验/NCT00956592
NCT00956592已完成不适用

A Randomized Control Trial to Determine First Attempt Intubation Success With the CMAC Laryngoscope vs. Macintosh Blade in Airways Predicted to be Difficult

Oregon Health and Science University2 个研究点 分布在 1 个国家目标入组 300 人开始时间: 2009年10月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
300
试验地点
2
主要终点
Measure of Intubation Success

研究概览

简要总结

This study aims to evaluate the utility of a video assisted device for intubation (placement of a breathing tube) during surgery. This study specifically aims to compare a video assisted intubation with the CMAC laryngoscope to conventional devices in the setting of intubations predicted to be difficult.

详细描述

Patients will be specifically screened for predictors by history and physical exam of potential airway difficulty. The role of video laryngoscopy in airways predicted to be difficult is poorly defined. This study aims to recognize if video laryngoscopy is more useful than conventional laryngoscopy as a first attempt for those with anticipated difficulty.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

入排标准

年龄范围
18 Years 至 99 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adult patients presenting for elective surgery who are fasted and who have one of the following difficult airway predictors:
  • mallampati classification 3
  • mallampati classification 4
  • Reduced mouth opening (<3cm)
  • reduced cervical motion
  • history of previous difficult intubation or multiple laryngoscopy attempts

排除标准

  • Patients less than 18 years old, patients who are not fasted (>6 hrs. NPO)
  • Patients who have contraindications to the administration of neuromuscular blocking drugs
  • Patients who have a documented history of intubation on first attempt with C-L grade 1 laryngeal view
  • Patients who are deemed to difficult and dangerous to anesthetize without first securing an airway.

研究组 & 干预措施

CMAC Video laryngoscope

Active Comparator

Subjects will have their intubation attempted first with the CMAC video laryngoscope

干预措施: CMAC video laryngoscope (Device)

Macintosh blade

Active Comparator

Patients will have their first intubation attempted utilizing the conventional Macintosh design laryngoscope blade

干预措施: Macintosh laryngoscope (Device)

结局指标

主要结局

Measure of Intubation Success

时间窗: During each intubation in a 14 month period

Success was measured by confirmed tracheal tube placement with one attempt. Any removal of the laryngoscope blade constituted a failure

次要结局

  • Intubation Time(During laryngoscopy procedure)
  • Number of Participants Intubated With a Rescue Device(1 year)
  • Number of Participants With Complications(1 year)
  • Number of Participants With a Laryngeal View Grade of 1 or 2 vs. 3 or 4.(1 year)
  • Number of Particpants Requiring Adjuncts to Assist Intubation(1 year)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michael Aziz

Associate Professor Department of Anesthesiology & Perioperative Medicine

Oregon Health and Science University

研究点 (2)

Loading locations...

相似试验