Radiomics of Immunotherapeutics Response Evaluation and Prediction in Solid Tumor: A Multicenter Diagnostic Study
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 285
- 试验地点
- 1
- 主要终点
- Area Under the receiver operating characteristic curve (ROC)
研究概览
简要总结
This study aims to investigate the feasibility and efficiency of CT radiomic analysis which serves as a high through-put analytical strategy applied to image big-data resource in evaluating and predicting the response of immunotherapeutics. A multi-center retrospective diagnostic test has been designed for this aim to compare the predictive performance of clinical model, qualitative model incorporating semantic CT features and image-based quantitative radiomic model. The reference standard of therapeutic effect is determined by the latest evaluation result utilizing iRECIST within 365 days after recruited. This study intends to enroll 400 participates who had been diagnosed with advanced somatic solid tumor confirmed by histo- or cyto-pathological examination and were planning to receive immunotherapy.
研究设计
- 研究类型
- Observational
- 观察模型
- Case Only
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients with histopathological or cytopathological confirmed solid tumor (including metastatic solid tumor).
- •Patients ≥ 18 years of age on the day of baseline CT scan.
- •Patients received immune checkpoint inhibitors (ICI) monotherapy or combined with chemotherapy in any line of treatment.
- •Patients with at least one measurable target lesion of which minor axis was greater than 15mm and without any local treatment.
- •Female with a negative pregnancy test, or male who agree to use barrier methods of contraception through the therapy period.
- •Patients with a Eastern Cooperative Oncology Group(ECOG) performance status score of 0 or
- •Patients underwent follow-up CT scans with an 6-9-week interval until 365 days after baseline CT scan.
- •Patients with baseline and follow-up CT scans which meet the following conditions: a) Spiral computed tomography device of General Electric Healthcare or Siemens with greater than 16 rows of detectors ; b) Peak kilovoltage: 120kV; c) Dose: auto or fixed; d) Slice resolution: not less than 512 pixels multiply 512 pixels; e) Scanning range: from supraclavicular region to 2cm below the costophrenic angle for thorax, and from diaphragm to pubic symphysis for abdomen; f) contrast-enhanced scan utilizing nonionic low- or iso-osmolar contrast agent and including arterial phase, venous phase and delayed phase at least.
排除标准
- •Patients received any kinds of cytotoxic drugs or experimental drugs 2 weeks before enrollment.
- •Patients meet the contraindications of contrast-enhanced CT scan.
- •Patients who were not suitable for continuous follow-up CT scans.
- •Patients with severe myocardial infarction confirmed by ECG or left ventricular ejection fraction(LVEF) less than 40% or glomerular filtration rate(GFR) less than 45ml/min.
- •Patients who cannot tolerate immunotherapy or with serious immune-related adverse response.
- •Patients with severe interstitial pneumonia confirmed by baseline CT scan.
- •Patients who cannot complete follow-up examinations scheduled by study design.
- •Patients with AIDS or positive serum HIV antibodies.
- •Patients with a CT scan presenting extremely low signal noise ratio or too much artifacts at any timepoint.
结局指标
主要结局
Area Under the receiver operating characteristic curve (ROC)
时间窗: 6 months and 1 year since course start (365 days)
Area under curve (AUC) of each diagnostic model
次要结局
- Disease Control Rate(6 months and 1 year since course start (365 days))
- Incidence(Through study completion, an average of 1 year)