Minimally-Invasive Realtime Assessment of Continuous Lactate in Exercise
试验速览
- 阶段
- 不适用
- 入组人数
- 15
- 试验地点
- 2
- 主要终点
- Performance of microneedle
研究概览
简要总结
Lactate is a compound produced as a by-product of glycolysis. The increase in lactate concentration can result from a variety of causes, such as during anaerobic metabolism in exercise or haemodynamic shock in conditions such as sepsis.
The study will aim to validate a novel microneedle-based minimally invasive device for the continuous measurement of lactate during exercise.
详细描述
Lactate is a compound produced as a by-product of glycolysis. The increase in lactate concentration can result from a variety of causes, such as during anaerobic metabolism in exercise. The measurement of blood lactate during exercise has been routinely used to determine individual anaerobic thresholds, and optimise training in athletes.
The measurement of the lactate trend requires multiple blood tests, and this can be uncomfortable. The need for repeated procedures may therefore restrict the full utility of the biomarker. Although point-of-care lactate measurements are possible, the barriers to initiating testing may also limit its role in clinical decision-making.
The aim of the study is the validation of the microneedle-based lactate biosensor for real-time continuous lactate measurement in healthy volunteers during exercise as proof-of-concept.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Device Feasibility
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Consenting adults ≥ 18 years old
- •Healthy with no other previous medical history
- •Able to perform moderately intensive exercise without difficulty for at least 30 minutes continuously, and engages in regular aerobic exercise at least twice a week
排除标准
- •Active inflammatory skin condition such as eczema or dermatitis
- •Active soft tissue infection or infection at any site
- •Known hypersensitivity to any microneedle component or dressings
- •Presence of any implantable electronic devices such as a pacemaker or stimulators
结局指标
主要结局
Performance of microneedle
时间窗: 30 minutes
Precision and accuracy of the lactate microneedle with reference to venous lactate as a gold standard. Current output from microneedle will be analysed against venous lactate and microdialysis lactate concentrations taken from participants every 5 minutes and concordance assessed through Bland-Altman analyses.
次要结局
- Acceptability(2 hours)